Level Instruments Sample Clauses

Level Instruments. Reflex-glass, liquid-free, or magnetic level gauges (Xxxxxxxxx or equal) will be used. Sump pump motors will be controlled by displacer or float-type level switches supplied by the sump pump manufacturer. Level transmitters for measuring the level in storage tanks vented to atmosphere (e.g., makeup water storage tank, demineralized water storage tank) will generally be the flanged mounted differential pres­sure type flush diaphragm and will be equipped with local indication as well as central control room indication. Differential Pressure type level instruments will normally be used for all services except for vacuum services. When differential pressure type instruments are to be mounted at or below the taps, they shall be furnished with zero elevation or suppression adjustment. External displacement type instruments shall normally conform to the following: Material shall normally be fabricated carbon steel, with stainless steel displacer and Inconel torque tube. Where vessels are of alloy construction, body material shall be equivalent or better. Air Fins or heat insulators shall be used at operating temperatures above 400°F and below 0°F for displacers with pneumatic pilots. Where displacers with electronic transmitters are used, they shall have air fins or heat insulators above 250°F and below 0°F. Connections shall normally be 1-1/2-inch flanged with bottom-side and top-side connections. Flange ratings shall be in accordance with vessel trim specification. Rotatable Heads shall normally be specified. Transmitter Output shall be 4 to 20 ma dc. Direct operated type level controls (e.g. ball float, mechanically linked valve), shall be used on utility service only. Special level problems will arise periodically and will require special level measuring devices such as internal displacers or floats, bubblers, and electronic types (capacitance, ultrasonic, nuclear, conductive, or electrical resistance).
AutoNDA by SimpleDocs
Level Instruments. A graphic indication on the DCS CRT (driven by the differential pressure level transmitters on each drum) will be provided to meet the ASME drum level monitoring requirements in the central control room. Reflex-glass, liquid-free, or magnetic level gauges (Xxxxxxxxx or equal) will be used. Sump pump motors will be controlled by displacer or float-type level switches supplied by the sump pump manufacturer. Level transmitters for measuring the level in storage tanks vented to atmosphere (e.g., makeup water storage tank, demineralized water storage tank) will generally be the flange-mounted differential pressure type flush diaphragm and will be equipped with local indication as well as central control room indication. Differential pressure type level instruments will normally be used for all services except for vacuum services. When differential pressure type instruments are to be mounted at or below the taps, they shall be furnished with zero elevation or suppression adjustment. External displacement type instruments shall normally conform to the following: Material shall normally be fabricated carbon steel, with stainless steel displacer and Inconel torque tube. Where vessels are of alloy construction, body material shall be equivalent or better. Air fins or heat insulators shall be used at operating temperatures above 400°F and below 0°F for displacers with pneumatic pilots. Where displacers with electronic transmitters are used, they shall have air fins or heat insulators above 250°F and below 0°F. Connections shall normally be 1.5-inch flanged with bottom-side and top-side connections. Flange ratings shall be in accordance with vessel trim specification. Rotatable heads shall normally be specified. Transmitter Output shall be 4 to 20 ma dc. Direct operated type level controls (e.g. ball float, mechanically linked valve) shall be used on utility service only. Special level problems will arise periodically and will require special level measuring devices such as internal displacers or floats, bubblers, and electronic types (capacitance, ultrasonic, nuclear, conductive, or electrical resistance).

Related to Level Instruments

  • Financial Instruments Not applicable

  • Risk Management Instruments Except as would not, individually or in the aggregate, reasonably be expected to have a Company Material Adverse Effect, all derivative instruments, including, swaps, caps, floors and option agreements, whether entered into for the Company’s own account, or for the account of one or more of the Company Subsidiaries or its or their customers, were entered into (i) only in the ordinary course of business, (ii) in accordance with prudent practices and in all material respects with all applicable laws, rules, regulations and regulatory policies and (iii) with counterparties believed to be financially responsible at the time; and each of such instruments constitutes the valid and legally binding obligation of the Company or one of the Company Subsidiaries, enforceable in accordance with its terms, except as may be limited by the Bankruptcy Exceptions. Neither the Company or the Company Subsidiaries, nor, to the knowledge of the Company, any other party thereto, is in breach of any of its obligations under any such agreement or arrangement other than such breaches that would not, individually or in the aggregate, reasonably be expected to have a Company Material Adverse Effect.

  • Additional Instruments The Member will execute and deliver any document or statement necessary to give effect to the terms of this Agreement or to comply with any law, rule or regulation governing the Company’s formation and activities.

  • Recorded Instruments Within thirty (60) days of Closing, Escrow Agent shall furnish to OPWC copies of the Settlement Statement, recorded Conveyance Instrument and recorded Deed Restrictions.

  • Further Assurances and Corrective Instruments Issuer and Company agree that they will, from time to time, execute, acknowledge and deliver, or cause to be executed, acknowledged and delivered, such supplements hereto and such further instruments as may reasonably be required for carrying out the intention of or facilitating the performance of this Agreement.

  • Security Instruments (i) The Administrative Agent shall fail to have an Acceptable Security Interest in any portion of the Collateral or (ii) any Security Instrument shall at any time and for any reason cease to create the Lien on the Property purported to be subject to such agreement in accordance with the terms of such agreement, or cease to be in full force and effect, or shall be contested by the Borrower, any Guarantor or any of their respective Subsidiaries;

  • FEDERAL ASSURANCES Grantee further certifies that, to the extent Federal Assurances are incorporated into the Contract under the Signature Document, the Grantee has reviewed the Federal Assurances and that Grantee is in compliance with all requirements.

  • Delivery of Instruments Xxxxxx Xxx shall furnish to each Holder, upon request, copies of this Trust Agreement, without attachments, applicable to the Certificate(s) held by such Holder.

  • Housing Assignments The University assigns Licensee to a bed space and does not guarantee specific room types, buildings, communities, or roommates. The University shall have the right to reassign the Licensee to a different bed space without the Licensee’s consent prior to or during the term of the Agreement.

  • Assumption of Tariff Obligations Interconnection Customer agrees to abide by all rules and procedures pertaining to generation and transmission in the PJM Region, including but not limited to the rules and procedures concerning the dispatch of generation or scheduling transmission set forth in the Tariff, the Operating Agreement and the PJM Manuals.