Common use of ELP Stillwater Solar Collector Substation Clause in Contracts

ELP Stillwater Solar Collector Substation. The ELP Stillwater Solar Collector Substation will be located approximately 100 feet northeast of Line 3 and will be comprised of the following major equipment: SERVICE AGREEMENT NO. 2550 • one (1) three phase, three winding, 115-34.5/13.8kV grounded wye-grounded wye, step-up transformer rated 15/20/25MVA (ONAN/ONAF/ONAF), with impedance of 9.0%; • six (6) 96kV, 76kV maximum continuous operating voltage (“MCOV”) station class surge arresters; • one (1) 115kV, 1200A, 550kV basic insulation level (“BIL”) group operated air break switch; • one (1) 115kV, 1200A, 550kV BIL, 40 kAIC SF-6 circuit breaker; • three (3) 24.4kV MCOV station class surge arresters; • one (1) 34.5kV, 1200A, 150kV BIL switchgear containing: o two (2) group operated air break switches; o one (1) 38kV, 1200A, 150kV BIL, 25kAIC vacuum circuit breaker; o three (3) 24.4kV MCOV station class surge arresters; o three (3) 38kV, potential transformers (“PTs”) 300:1; o three (3) 38kV, current transformers (“CTs”) 1200:5, C200 o one (1) 25kVA 19.9kV-120/240v station service transformer.

Appears in 3 contracts

Samples: Service Agreement, Service Agreement, Service Agreement

AutoNDA by SimpleDocs

ELP Stillwater Solar Collector Substation. The ELP Stillwater Solar Collector Substation will be located approximately 100 feet northeast of Line 3 and will be comprised of the following major equipment: SERVICE AGREEMENT NO. 2550 • one (1) three phase, three winding, 115-34.5/13.8kV grounded wye-grounded wye, step-up transformer rated 15/20/25MVA (ONAN/ONAF/ONAF), with impedance of 9.0%; • six (6) 96kV, 76kV maximum continuous operating voltage (“MCOV”) station class surge arresters; • one (1) 115kV, 1200A, 550kV basic insulation level (“BIL”) group operated air break switch; • one (1) 115kV, 1200A, 550kV BIL, 40 kAIC SF-6 circuit breaker; • three (3) 24.4kV MCOV station class surge arresters; • one (1) 34.5kV, 1200A, 150kV BIL switchgear containing: o two (2) group operated air break switches; o one (1) 38kV, 1200A, 150kV BIL, 25kAIC vacuum circuit breaker; o three (3) 24.4kV MCOV station class surge arresters; o three (3) 38kV, potential transformers (“PTs”) 300:1; o three (3) 38kV, current transformers (“CTs”) 1200:5, C200 o one (1) 25kVA 19.9kV-120/240v station service transformer.

Appears in 2 contracts

Samples: Service Agreement, Service Agreement

AutoNDA by SimpleDocs
Time is Money Join Law Insider Premium to draft better contracts faster.