Electrolyte Handling Clause Samples
Electrolyte Handling. 1077 A typical aqueous liquid electrolyte used in Flow Batteries has a concentration of approximately 10-20 % by 1078 weight of acid/alkali in water, and these strong corrosive agents may burn skin and eyes; and cause damage 1079 to clothing and other materials. 1080 Non aqueous electrolytes used in some types of Flow Batteries may have similar caustic or corrosive 1081 properties. 1082 The section shall provide details on the primary emergency measures that shall be taken if there is exposure 1083 to electrolytes. .. 1084 It shall also list requirements for protective equipment such as 1085 safety eye wear, 1086 chemical-resistant gloves, 1087 synthetic clothing (gear), 1088 safety boots with acid-resistant soles, 1089 acid-proof aprons. 1090 and requirements for emergency equipment such as 1091 Eye wash station, 1092 Chemical shower, 1093 First aid kit that includes oxygen and facemask, 1094 Fire extinguishers.
