Compute RTO Generation Serving RTO Load. Using the real-time generation output in MWs, compute the Generation serving RTO Load. Sum the output of RTO generation within each load zone: , for each RTO load zone Where: zone = the relevant RTO load zone; unit = the relevant generator; RTO_Genzone = the sum of the RTOβs generation in a zone; and Genunit,zone = the real-time output of the unit in a given zone. Next, reduce the RTO generation located within a load zone by the scheduled line real-time export transaction schedules that source from that particular load zone: Where: zone = the relevant RTO load zone; scheduled_line = each of the Transmission Facilities identified in Table 1 above; RTO_Reduced_Genzone = the sum of the RTOβs generation in a zone reduced by the sum of export schedules over scheduled lines from the zone; RTO_Genzone = the sum of the RTOβs generation in a zone; and Export_Schedulesscheduled_line,zone = export schedules from a zone over a scheduled line. The real-time export schedules over scheduled lines will only reduce the generation in the source zones identified in Table 1 above. The resulting generator output based on this reduction is defined below.
Appears in 35 contracts
Samples: Joint Operating Agreement, Joint Operating Agreement, Joint Operating Agreement
Compute RTO Generation Serving RTO Load. Using the real-time generation output in MWs, compute the Generation serving RTO Load. Sum the output of RTO generation within each load zone: π’πππ‘=1 π
ππ_πΊπππ§πππ = βπππ πΊπππ’πππ‘,π§πππ, for each RTO load zone Where: zone = the relevant RTO load zone; unit = the relevant generator; RTO_Genzone = the sum of the RTOβs generation in a zone; and Genunit,zone = the real-time output of the unit in a given zone. Next, reduce the RTO generation located within a load zone by the scheduled line real-time export transaction schedules that source from that particular load zone: Where: π
ππ_π
πππ’πππ_πΊπππ§πππ = π
ππ_πΊπππ§πππ β β πΈπ₯ππππ‘_ππβπππ’πππ π πβπππ’πππ_ππππ,π§πππ π πβπππ’πππ_ππππ=1 zone = the relevant RTO load zone; scheduled_line = each of the Transmission Facilities identified in Table 1 above; RTO_Reduced_Genzone = the sum of the RTOβs generation in a zone reduced by the sum of export schedules over scheduled lines from the zone; RTO_Genzone = the sum of the RTOβs generation in a zone; and Export_Schedulesscheduled_line,zone = export schedules from a zone over a scheduled line. The real-time export schedules over scheduled lines will only reduce the generation in the source zones identified in Table 1 above. The resulting generator output based on this reduction is defined below.
Appears in 1 contract
Samples: Joint Operating Agreement