Class IA and Class IB Sample Clauses

Class IA and Class IB. 5.1.4.4.1. When measured as described in paragraph 3. of Annex 4, the CIL values for red retro-reflective devices must be equal to or greater than those in Table 3, expressed in millicandelas per lux, for the angles of divergence and illumination shown. Table 3 Requirements for CIL values (Classes IA and IB) [mcd.lx-1] Class Angle of divergence α Illumination angles (in degrees) Vertical V Horizontal H 0° 0° ±10° 0° ±5° ±20° IA, IB 20' 1°30' 300 5 200 2.8 100 2.5 CIL values lower than those shown in the last two columns of Table 3 are not permissible within the solid angle having the centre of reference as its apex and bounded by the planes intersecting along the following lines:
AutoNDA by SimpleDocs
Class IA and Class IB. 5.1.4.4.1. When measured as described in paragraph 3 of Part 1 of Annex 4, the RI values for red retro-reflectors must be equal to or greater than those in Table 3, expressed in millicandelas per lux, for the angles of divergence and illumination shown. Table 3 Requirements for RI values of Retro-reflectors Angles in degrees Class Colour Illumination angles [º] Vertical β1 0° ±10° ±5° 0° 0° 0° Horizontal β2 0° 0° ±20° ±30° ±40° ±50° Minimum requirements for RI values in mcd∙lx-1 IA, IB White Angle of divergxxxx x 00' 1.20∙103 8.00∙102 4.00∙102 -- -- -- 1°30' 2.0∙101 1.12∙101 1.0∙101 -- -- -- Amber 20' 7.50∙102 5.00∙102 2.50∙102 -- -- -- 1°30' 1.25∙101 7∙100 6.25∙100 -- -- -- Red 20' 3.00∙102 2.00∙102 1.00∙102 -- -- -- 1°30' 5∙100 2.8∙100 2.5∙100 -- -- -- IIIA, IIIB White 20' 1.80∙103 8.00∙102 6.00∙102 -- -- -- 1°30' 4.8∙101 3.2∙101 3.2∙101 -- -- -- Amber 20' 1.13∙103 5.00∙102 3.75∙102 -- -- -- 1°30' 3.0∙101 2.0∙101 2.0∙101 -- -- -- Red 20' 4.50∙102 2.00∙102 1.50∙102 -- -- -- 1°30' 1.2∙101 8∙100 8∙100 -- -- -- IV White 20' 1.80∙103 1.20∙103 -- 5.40∙102 4.70∙102 4.00∙102 1°30' 3.4∙101 2.4∙101 -- 1.5∙101 1.5∙101 1.5∙101 Amber 20' 1.13∙103 7.50∙102 -- 3.35∙102 2.90∙102 2.50∙102 1°30' 2.1∙101 1.5∙101 -- 1.0∙101 1.0∙101 1.0∙101 Red 20' 4.50∙102 3.00∙102 -- 1.35∙102 1.15∙102 1.00∙102 1°30' 9∙100 6∙100 -- 4∙100 4∙100 4∙100 RI values lower than those shown in the last two columns of Table 3 are not permissible within the solid angle having the centre of reference as its apex and bounded by the planes intersecting along the following lines: (β1 = ±10°, β2 = 0°) (β1 = ±5°, β2 = ±20°).
Class IA and Class IB. 4.1.4.4.1.When measured as described in paragraph 3 and Annex 4, the CIL values for red retro-reflecting devices must be equal to or greater than those in Table 2, expressed in millicandelas per lux, for the angles of divergence and illumination shown.

Related to Class IA and Class IB

  • Class Size The School shall be in compliance with Florida Constitutional Class Size Requirements, as applicable to charter schools.

  • Class All REMIC I Regular Interests or the Class R-1 Residual Interest having the same priority and rights to payments on the Mortgage Loans from the REMIC I Available Distribution Amount, all REMIC II Regular Interests or the Class R-2 Residual Interest having the same priority and rights to payments on the REMIC I Regular Interests from the REMIC II Available Distribution Amount, and all REMIC III Regular Interests or the Class R-3 Residual Interest having the same priority and rights to payments on the REMIC II Regular Interests from the REMIC III Available Distribution Amount, as applicable, which REMIC I Regular Interests, REMIC II Regular Interests, REMIC III Regular Interests and Class R Residual Interests, as applicable, shall be designated as a separate Class, and which, in the case of the Certificates (including the Class R Certificates representing ownership of the Class R Residual Interests), shall be set forth in the applicable forms of Certificates attached hereto as Exhibits A and B. Each Class of REMIC I Regular Interests and the Class R-1 Residual Interest shall be entitled to receive the amounts allocated to such Class pursuant to the definition of "REMIC I Distribution Amount" only to the extent of the REMIC I Available Distribution Amount for such Distribution Date remaining after distributions in accordance with prior clauses of the definition of "REMIC I Distribution Amount," each Class of REMIC II Regular Interests and the Class R-2 Residual Interest shall be entitled to receive the amounts allocated to such Class pursuant to the definition of "REMIC II Distribution Amount" only to the extent of the REMIC II Available Distribution Amount for such Distribution Date remaining after distributions in accordance with prior clauses of the definition of "REMIC II Distribution Amount" and each Class of REMIC III Regular Interests and the Class R-3 Residual Interest shall be entitled to receive the amounts allocated to such Class pursuant to the definition of "REMIC III Distribution Amount" only to the extent of the REMIC III Available Distribution Amount for such Distribution Date remaining after distributions in accordance with prior clauses of the definition of "REMIC III Distribution Amount."

Time is Money Join Law Insider Premium to draft better contracts faster.