True-up of Monthly Costs Sample Clauses

True-up of Monthly Costs. 13.6.1 Until such time as a competitively neutral cost recovery mechanism is implemented pursuant to a PUC or FCC order ("the Interim Recovery Period"), the Parties shall track and record the cumulative sum of ported numbers provided via an to each other each month for the purpose of calculating an true-up amount that the Party providing an functionality may then be entitled to bill and receive under such PUC or FCC order. The true-up amount shall equal the sum of the ported number provided to the Party receiving the functionality, multiplied by the number of months applicable to each ported number during the Recovery Period, multiplied by the Final Rate set by the PUC or FCC.
AutoNDA by SimpleDocs

Related to True-up of Monthly Costs

  • Monthly Charges Purchaser shall pay Seller monthly for the electric energy generated by the System and delivered to the Delivery Point at the $/kWh rate shown in Exhibit 1 (the “Contract Price”). The monthly payment for such energy will be equal to the applicable $/kWh rate multiplied by the number of kWh of energy generated during the applicable month, as measured by the System meter.

  • Actual Costs The Consultant can invoice the City for no more than the actual cost of each subconsultant plus a specified markup not to exceed 5 percent.

  • Recover Copying Costs The Participating Institutions may impose a reasonable fee on the Authorized Users to cover costs of copying or printing portions of the Licensed Materials by or for the Authorized Users.

  • Monthly Billing The electric service charge shall be computed in accordance with the monthly billing in the applicable standard service tariff. Customers receiving electric service under residential and small nonresidential schedules 1, 2, 3, 15, 23 or 23B shall be financially credited for such net energy with a cumulative kilowatt-hour credit. The credit will be deducted from the customer’s kilowatt-hour usage on the customer’s next monthly bill thus offsetting the customer’s next monthly bill at the full retail rate of the customer’s rate schedule. Customers receiving electric service under large nonresidential schedules 6, 6A, 6B, 8 or 10 must elect a compensation method to receive cumulative credits for the upcoming annualized billing period from one of the following options (large nonresidential customers must initial desired credit election): an average energy price, a seasonally differentiated energy price, or an average retail rate.

  • Payment of Monthly Bills 10.3.1 SECI shall pay the amount payable under the Monthly Xxxx/Supplementary Xxxx by the Due Date to such account of the SPD, as shall have been previously notified by the SPD in accordance with Article10.3.2 (iii) below.

  • Estimated Costs The proposed GMP Change Order shall include separately identified dollar amounts, stated as fixed sums, for Actual Costs as estimated by the Design-Builder for the complete construction of the Project, which amount shall include the all Trade Contract and Subcontract Sums, costs of materials, and any Component Change Order Sums;

  • CAISO Monthly Billed Fuel Cost [for Geysers Main only] The CAISO Monthly Billed Fuel Cost is given by Equation C2-1. CAISO Monthly Billed Fuel Cost Equation C2-1 = Billable MWh ◆ Steam Price ($/MWh) Where: • Steam Price is $16.34/MWh. • For purposes of Equation C2-1, Billable MWh is all Billable MWh Delivered after cumulative Hourly Metered Total Net Generation during the Contract Year from all Units exceeds the Minimum Annual Generation given by Equation C2-2. Equation C2-2 Minimum Annual Generation = (Annual Average Field Capacity ◆ 8760 hours ◆ 0.4) - (A+B+C) Where: • Annual Average Field Capacity is the arithmetic average of the two Field Capacities in MW for each Contract Year, determined as described below. Field Capacity shall be determined for each six-month period from July 1 through December 31 of the preceding calendar year and January 1 through June 30 of the Contract Year. Field Capacity shall be the average of the five highest amounts of net generation (in MWh) simultaneously achieved by all Units during eight-hour periods within the six-month period. The capacity simultaneously achieved by all Units during each eight-hour period shall be the sum of Hourly Metered Total Net Generation for all Units during such eight-hour period, divided by eight hours. Such eight-hour periods shall not overlap or be counted more than once but may be consecutive. Within 30 days after the end of each six-month period, Owner shall provide CAISO and the Responsible Utility with its determination of Field Capacity, including all information necessary to validate that determination. • A is the amount of Energy that cannot be produced (as defined below) due to the curtailment of a Unit during a test of the Facility, a Unit or the steam field agreed to by CAISO and Owner. • B is the amount of Energy that cannot be produced (as defined below) due to the retirement of a Unit or due to a Unit’s Availability remaining at zero after a period of ten Months during which the Unit’s Availability has been zero. • C is the amount of Energy that cannot be produced (as defined below) because a Force Majeure Event reduces a Unit’s Availability to zero for at least thirty (30) days or because a Force Majeure Event reduces a Unit’s Availability for at least one hundred eighty (180) days to a level below the Unit Availability Limit immediately prior to the Force Majeure Event. • The amount of Energy that cannot be produced is the sum, for each Settlement Period during which the condition applicable to A, B or C above exists, of the difference between the Unit Availability Limit immediately prior to the condition and the Unit Availability Limit during the condition.

  • Monthly Invoices On or before the tenth (10th) day following the end of each calendar month, Seller shall deliver to PacifiCorp a proper invoice showing Seller's computation of Net Output delivered to the Point of Delivery during such month. When calculating the invoice, Seller shall provide computations showing the portion of Net Output that was delivered during On-Peak Hours and the portion of Net Output that was delivered during Off-Peak Hours. If such invoice is delivered by Seller to PacifiCorp, then PacifiCorp shall send to Seller, on or before the later of the twentieth (20th) day following receipt of such invoice or the thirtieth (30th) day following the end of each month, payment for Seller's deliveries of Net Output and associated Green Tags to PacifiCorp.

  • Monthly Statements Each month we will send you a statement showing purchases, cash advances, payments, and credits made to your Account during the billing cycle, as well as your “New Balance”, any Finance Charge and any late charges. Your statement also will identify the minimum monthly payment you must make for that billing period and the date it is due. You agree to retain for statement verification copies of transaction slips resulting from each purchase, each advance, and other transactions on your Account. Unless you notify us of a billing error in accordance with the section entitled “Your Billing Rights”, you accept your monthly statement as an accurate statement of your Account with us.

  • Monthly Statement The Contractor shall submit a statement to the Engineer at the end of each month, in a tabulated form approved by the Engineer, showing the amounts to which the Contractor considers himself to be entitled. The statement shall include the following items, as applicable; - the value of the Permanent Work executed up to the end of previous month - such an amount (not exceeding 75 percent of the value) as the Engineer may consider proper on account of materials for permanent work delivered by the Contractor in the site - such amount as the Engineer may consider fair and reasonable for any Temporary Works for which separate amounts are provided in the Bill of Quantities - adjustments under Clause 70 - any amount to be withheld under retention provisions of Sub-clause 60.3 - any other sum to which the Contractor may be entitled under the Contract If the Engineer disagrees with or cannot verify any part of the statement, the Contractor shall submit such further information as the Engineer may reasonably require and shall make such changes and corrections in the statement as may be directed by the Engineer. In cases where there is difference in opinion as to the value of any item, the Engineer’s view shall prevail.

Time is Money Join Law Insider Premium to draft better contracts faster.