Testing and commissioning Clause Sample Clauses
POPULAR SAMPLE Copied 19 times
Testing and commissioning Clause. It is understood and agreed that acceptance of new property hereon - other than as provided (Capital Additions/ Newly acquired Property/Interests) - is subject to satisfactory completion of the following procedures: Mechanical completion including testing.
a) Testing and commissioning conforming to 100% (one hundred per cent) Contract Design to temperatures and pressures maintained by the entire plant in a stable and controlled manner for a continuous ongoing period of a minimum of 72 hours duration all as approved by the Insured and an engineer firm or licenser involved in said project or as per standard practice of the contractor or the licensor.
b) Official acceptance by the Insured following formal handover without reservation or waiver of guarantee conditions to suppliers of equipment in respect of said mechanical specifications it being understood that no equipment faults or punch list items affecting mechanical integrity of the plant are outstanding and that no temporary structures and no modifications remain as shall be notified by the Insured In the event that compliance with (a) and (b) above will be deferred upon mechanical completion and testing the Insured agrees to advise the Company in writing of such alternative procedures which will be adopted prior to the attachment hereunder of such new property. Notwithstanding the above, in respect of acquisitions exceeding the sum noted in the Schedule of property and plant hereon, these are to be agreed by Insurers. It is further noted and agreed that the terms and conditions are to be reviewed by the Company. The above provisions do not apply to normal routine, maintenance activities and scheduled turnarounds. Subject otherwise to the terms, conditions and exclusions of the Policy.
Testing and commissioning Clause. It is hereby noted and agreed that this Insurance does not extend to cover destruction or damage to property in course of construction or erection, dismantling, revamp or undergoing testing or commissioning including mechanical performance testing or any consequential loss resulting therefrom. Acceptable of property hereon is subject to satisfactory completion of the following procedures and otherwise to the terms and conditions of this Policy.
i) The plant is mechanically complete This requires all key items to be complete and that no temporary structures (such as pipe supports) remain awaiting permanent fixture
ii) Plant Testing and commissioning has been completed with the design/ construction/ erection contract performance levels having been satisfactory achieved
iii) Design performance criteria maintained by the entire plant in a stable and controlled manner for a continuous ongoing period of one hundred and sixty eight (168) hours
iv) The Insured has accepted the plant without reservation or waiver of guarantee conditions It is further noted and agreed that these provisions do not apply to normal routine maintenance activities and scheduled turnarounds It is understood and agreed that losses excluded by this Sub-Section 1 (a) and not otherwise excluded by Section 1 shall be deemed covered by Section 1.
