Technology Upgrades Notwithstanding any other provision of this Agreement, Verizon shall have the right to deploy, upgrade, migrate and maintain its network at its discretion. The Parties acknowledge that Verizon, at its election, may deploy fiber throughout its network and that such fiber deployment may inhibit or facilitate Covista’s ability to provide service using certain technologies. Nothing in this Agreement shall limit Verizon's ability to modify its network through the incorporation of new equipment or software or otherwise. Covista shall be solely responsible for the cost and activities associated with accommodating such changes in its own network.
Utilization Utilization shall be defined as Trunks Required as a percentage of Trunks In Service. 1 During implementation the Parties will mutually agree on an Economic Centum Call Seconds (ECCS) or some other means for the sizing of this trunk group. 4.6.3.1 In A Blocking Situation (Over-utilization): 4.6.3.1.1 In a blocking situation, CLEC is responsible for issuing ASRs on all two-way Local Only, Local Interconnection, Third Party and Meet Point Trunk Groups and one-way CLEC originating Local Only and/or Local Interconnection Trunk Groups to reduce measured blocking to design objective blocking levels based on analysis of trunk group data. If an ASR is not issued, AT&T-21STATE will issue a TGSR. CLEC will issue an ASR within three (3) business days after receipt and review of the TGSR. CLEC will note “Service Affecting” on the ASR. 4.6.3.1.2 In a blocking situation, AT&T-21STATE is responsible for issuing ASRs on one-way AT&T-21STATE originating Local Only and/or Local Interconnection Trunk Groups to reduce measured blocking to design objective blocking levels based on analysis of trunk group data. If an ASR is not issued, CLEC will issue a TGSR. AT&T- 21STATE will issue an ASR within three (3) business days after receipt and review of the TGSR. 4.6.3.1.3 If an alternate final Local Only Trunk Group or Local Interconnection Trunk Group is at seventy-five percent (75%) utilization, a TGSR may be sent to CLEC for the final trunk group and all subtending high usage trunk groups that are contributing any amount of overflow to the alternate final route. 4.6.3.1.4 If a direct final Meet Point Trunk Group is at seventy-five percent (75%) utilization, a TGSR may be sent to CLEC. If a direct final Third Party Trunk Group is at ninety percent (90%) utilization, a TGSR may be sent to CLEC.
Synchronization, Commissioning and Commercial Operation 5.1.1 The SPG shall give PGVCL at least thirty (30) days’ advanced preliminary written notice and at least fifteen (15) days’ advanced final written notice, of the date on which it intends to synchronize the Solar Power Project to the Grid System. 5.1.2 Subject to Article 5.1.1, the Power Project may be synchronized by the SPG to the Grid System when it meets all the connection conditions prescribed in applicable Grid Code then in effect and otherwise meets all other Indian legal requirements for synchronization to the Grid System. 5.1.3 The synchronization equipment and all necessary arrangements / equipment including RTU for scheduling of power generated from the Project and transmission of data to the concerned authority as per applicable regulation shall be installed by the SPG at its generation facility of the Power Project at its own cost. The SPG shall synchronize its system with the Grid System only after the approval of synchronization scheme is granted by the head of the concerned substation/ and checking/verification is made by the concerned authorities of the PGVCL. 5.1.4 The SPG shall immediately after each synchronization/tripping of generator, inform the sub-station of the Grid System to which the Power Project is electrically connected in accordance with applicable Grid Code. In addition, the SPG will inject in-firm power to grid from time to time to carry out operational/ functional test prior to commercial operation. For avoidance of doubt, it is clarified that Synchronization / Connectivity of the Project with the grid shall not to be considered as Commissioning of the Project. 5.1.5 The SPG shall commission the Project within nine (9) Months from the Date of execution of this PPA. Declaration of COD shall be certified by the commissioning committee. 5.1.6 The Parties agree that for the purpose of commencement of the supply of electricity by SPG to PGVCL, liquidated damages for delay etc., the Scheduled Commissioning Date as defined in this Agreement shall be the relevant date.
Utilization Management Contractor shall maintain a utilization management program that complies with applicable laws, rules and regulations, including Health and Safety Code § 1367.01 and other requirements established by the applicable State Regulators responsible for oversight of Contractor.
Underutilization 4.6.3.2.1 Underutilization of Local Only Trunk Groups, Local Interconnection Trunk Groups, Third Party Trunk Group and Meet Point Trunk Groups exists when provisioned capacity is greater than the current need. Those situations where more capacity exists than actual usage requires will be handled in the following manner: 4.6.3.2.1.1 If a Local Only Trunk Group, Local Interconnection Trunk Group, Third Party Trunk Group or a Meet Point Trunk Group is under sixty-five percent (65%) of CCS capacity on a monthly average basis for AT&T- 12STATE or under eighty percent (80%) for AT&T SOUTHEAST REGION 9-STATE, for each month of any three (3) consecutive months period, either Party may request the issuance of an order to resize the Local Only Trunk Group, Local Interconnection Trunk Group, Third Party Trunk Group or the Meet Point Trunk Group, which shall be left with not less than twenty-five percent (25%) excess capacity for AT&T-12STATE or not less than fifteen percent (15%) for AT&T SOUTHEAST REGION 9-STATE. In all cases, grade of service objectives shall be maintained. 4.6.3.2.1.2 Either Party may send a TGSR to the other Party to trigger changes to the Local Only Trunk Groups, Local Interconnection Trunk Groups, Third Party Trunk Groups or Meet Point Trunk Groups based on capacity assessment. Upon receipt of a TGSR, the receiving Party will issue an ASR to the other Party within twenty (20) business days after receipt of the TGSR. 4.6.3.2.1.3 Upon review of the TGSR, if a Party does not agree with the resizing, the Parties will schedule a joint planning discussion within the twenty