SEISMIC BRACING. Provide splayed bracing wires as shown and required by the Uniform Building Code. Provide compression struts at 12'-0" o.c., both directions fastened to the main runner and a structural member above. Repair, Cleaning and Completion: Remove and replace all discolored, broken or damaged materials. Completed ceilings shall present a smooth level surface free of edge or corner offsets, cupping, scratches, gouges or other defects. Clean exposed surfaces and remove foreign matter.
Appears in 5 contracts
Sources: Office Lease (Peregrine Systems Inc), Lease Option Agreement (Peregrine Systems Inc), Office Lease (Peregrine Systems Inc)
SEISMIC BRACING. Provide splayed bracing wires as shown and required by the Uniform Building Code. Provide compression struts at 12'-0" 12β-0β o.c., both directions fastened to the main runner and a structural member above. Repair, Cleaning Clearing and Completion: Remove and replace all discolored, broken or damaged materials. Completed ceilings shall present a smooth level surface free of edge or corner offsets, cupping, scratches, gouges or other defects. Clean exposed surfaces and remove foreign matter.
Appears in 1 contract
Sources: Office Lease (Memec Inc)