Scantlings Sample Clauses

The 'Scantlings' clause defines the required dimensions, strength, and construction standards for the structural components of a vessel, such as frames, beams, and plating. In practice, this clause specifies the minimum measurements and materials that must be used to ensure the vessel's hull and supporting structures are robust enough to withstand operational stresses and comply with classification society rules. Its core function is to ensure the vessel's safety and seaworthiness by mandating construction standards that prevent structural failure.
Scantlings. Bulkhead
Scantlings. The steel to be used is to be of IS 2062 Grade B or equivalent and classification society shall carry out necessary testing of the samples of steel as required by class. The welding is to be of excellent quality and using high quality electrodes. The hull scantlings are to be not less than given below: a. Bottom Plating 6 mm b. Side plating 5 mm
Scantlings. The steel to be used is to be of IS 2062 Grade B or equivalent and classification society shall carry out necessary testing of the samples of steel as required by class. The welding is to be of excellent quality and using high quality electrodes. The hull scantlings are to be not less than given below: Plating a. Bottom Plating 8mm b. Side plating 6mm c. End bulkheads 6mm d. Internal bulkhead 6mm e. Deck plating 6mm chequered plats f. Tank boundaries 6mm Profiles (i) Bottom longitudinal 1A 75x75x8 (ii) Side shell stiffeners 1A 65x65x6 (iii) Deck longitudinal 1A65x65x6

Related to Scantlings

  • Breaker Breaker failure protection for the 115kV breaker will trip the appropriate adjacent breakers and send direct transfer trip to Connecting Transmission Owner’s Mohican and Schaghticoke Substations. For loss of SF6, the breaker must trip and block close. DTT receive from Schaghticoke and Mohican Substations will be required to trip the Interconnection Customer’s 115kV breaker for a line relay operation or breaker failure at Schaghticoke and Mohican Substations.

  • Infrastructure Vulnerability Scanning Supplier will scan its internal environments (e.g., servers, network devices, etc.) related to Deliverables monthly and external environments related to Deliverables weekly. Supplier will have a defined process to address any findings but will ensure that any high-risk vulnerabilities are addressed within 30 days.

  • Outputs Analogue and digital outputs of protected content are allowed if they meet the requirements in this section and if they are not forbidden elsewhere in this Agreement..

  • Generelt A. Apple Inc. (“Apple”) giver hermed licenstager licens til at bruge Apples software samt tredjeparters software, dokumentation, grænseflader, indhold, skrifter og evt. data, som følger med denne licens, uanset om de forefindes som ROM (Read Only Memory) eller på andet medie (under et kaldet “Apple- software”) i henhold til betingelserne i denne licensaftale. Apple og/eller Apples licensgivere bevarer ejendomsretten til selve Apple-softwaren og forbeholder sig alle de rettigheder, som ikke udtrykkeligt er givet til licenstager B. Apple vil efter eget valg evt. frigive fremtidige opgraderinger eller opdateringer til Apple-softwaren til licenstagers kompatible iOS- eller iPadOS-enhed (under et kaldet Apple-enhed) fra Apple. Evt. Apple- softwareopgraderinger og -opdateringer inkluderer ikke nødvendigvis alle de eksisterende softwarefunktioner eller nye funktioner, som Apple frigiver til nyere eller andre modeller af Apple-enheder. Licenstagers rettigheder i henhold til denne licens omfatter alle de softwareopgraderinger eller - opdateringer leveret af Apple til det originale Apple-softwareprodukt, medmindre opgraderingerne eller opdateringerne indeholder en separat licens, i hvilket fald licenstager erklærer sig indforstået med, at betingelserne i den licens er gældende for sådanne opgraderinger eller opdateringer

  • Check Meters Developer, at its option and expense, may install and operate, on its premises and on its side of the Point of Interconnection, one or more check meters to check Connecting Transmission Owner’s meters. Such check meters shall be for check purposes only and shall not be used for the measurement of power flows for purposes of this Agreement, except as provided in Article 7.4 below. The check meters shall be subject at all reasonable times to inspection and examination by Connecting Transmission Owner or its designee. The installation, operation and maintenance thereof shall be performed entirely by Developer in accordance with Good Utility Practice.