Providing Magnetic Detection for Underground Facilities Sample Clauses

Providing Magnetic Detection for Underground Facilities. ‌ 2 Developer shall provide magnetic detection in accordance with the ADOT Standard Specifications and
AutoNDA by SimpleDocs
Providing Magnetic Detection for Underground Facilities. ‌ 5 All new underground utility, drainage facilities, and ITS empty conduits, including service 6 connections, placed within Project ROW must be magnetically detectable with standard locating 7 instruments. Developer shall place continuous detectable tracer for all the underground facilities 8 that lack a continuous and integral metal component capable of detection by standard locating 9 instruments, in accordance with Section 104.15 of the ADOT Standard Specifications for Xxxx 00 and Bridge Construction.

Related to Providing Magnetic Detection for Underground Facilities

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Underground Facilities All underground pipelines, conduits, ducts, cables, wires, manholes, vaults, tanks, tunnels, or other such facilities or attachments, and any encasements containing such facilities, including without limitation those that convey electricity, gases, steam, liquid petroleum products, telephone or other communications, cable television, water, wastewater, storm water, other liquids or chemicals, or traffic or other control systems.

  • Use of Interconnection Facilities by Third Parties 6551 Error! Hyperlink reference not valid.9.9.1 Purpose of Interconnection Facilities. 6551

  • Infrastructure Vulnerability Scanning Supplier will scan its internal environments (e.g., servers, network devices, etc.) related to Deliverables monthly and external environments related to Deliverables weekly. Supplier will have a defined process to address any findings but will ensure that any high-risk vulnerabilities are addressed within 30 days.

  • Construction materials (1) The restrictions of section 1605 of the American Recovery and Reinvestment Act of 2009 (Pub. L. 111-5) (Recovery Act) do not apply to Recovery Act designated country manufactured construction material. The restrictions of the Buy American statute do not apply to designated country unmanufactured construction material. Consistent with U.S. obligations under international agreements, this clause implements--

  • Information regarding Interconnection Facilities 4.2.1 The SPD shall be required to obtain all information from the STU/CTU/concerned authority with regard to the Interconnection Facilities as is reasonably necessary to enable it to design, install and operate all interconnection plant and apparatus on the SPD’s side of the Delivery Point to enable delivery of electricity at the Delivery Point. The transmission of power up to the point of interconnection where the metering is done for energy accounting shall be the responsibility of the SPD at his own cost.

  • Access to Network Interface Device (NID 2.4.3.1. Due to the wide variety of NIDs utilized by BellSouth (based on subscriber size and environmental considerations), Mpower may access the on-premises wiring by any of the following means: BellSouth shall allow Mpower to connect its loops directly to BellSouth’s multi-line residential NID enclosures that have additional space and are not used by BellSouth or any other telecommunications carriers to provide service to the premise. Mpower agrees to install compatible protectors and test jacks and to maintain the protection system and equipment and to indemnify BellSouth pursuant to Section 8 of the General Terms and Conditions of this Agreement.

  • System Logging The system must maintain an automated audit trail which can 20 identify the user or system process which initiates a request for PHI COUNTY discloses to 21 CONTRACTOR or CONTRACTOR creates, receives, maintains, or transmits on behalf of COUNTY, 22 or which alters such PHI. The audit trail must be date and time stamped, must log both successful and 23 failed accesses, must be read only, and must be restricted to authorized users. If such PHI is stored in a 24 database, database logging functionality must be enabled. Audit trail data must be archived for at least 3 25 years after occurrence.

  • Verizon OSS Facilities Any gateways, interfaces, databases, facilities, equipment, software, or systems, used by Verizon to provide Verizon OSS Services to CBB.

  • CONTRACTOR PORTABLE DEVICES Contractor shall not place Data on any portable Device unless Device is located and remains within Contractor’s CONUS Data Center. For Authorized Users subject to ITS policies, the Data, and/or the portable device containing the Data, shall be destroyed in accordance with applicable ITS destruction policies (ITS Policy S13-003 Sanitization/Secure Disposal and S14-003 Information Security Controls or successor) when the Contractor is no longer contractually required to store the Data. TRANSFERRING OF DATA General Except as required for reliability, performance, security, or availability of the services, the Contractor will not transfer Data unless directed to do so in writing by the Authorized User. All Data shall remain in CONUS. At the request of the Authorized User, the Contractor will provide the services required to transfer Data from existing Databases to physical storage devices, to facilitate movement of large volumes of Data. The Authorized User may require several Cloud providers to share or transfer Data for a period of time. This will be provided for in the Authorized User Agreement or shall be assumed to be limited to a six month duration. Transfer of Data at End of Contract and/or Authorized User Agreement Term At the end of the Contract and/or Authorized User Agreement term, Contractor may be required to facilitate transfer of Data to a new Contractor. This transfer must be carried out as specified by the Authorized User in the Authorized User Agreement. Transfer of Data; Charges Contractor cannot charge for the transfer of Data unless the charges are provided for in response to an Authorized User RFQ. Transfer of Data; Contract Breach or Termination Notwithstanding Section 3.6.3, in the case of Contract breach or termination for cause of the Contract, all expenses for the transfer of Data shall be the responsibility of the Contractor.