Light Source and Power Meter Test Sample Clauses
The Light Source and Power Meter Test clause establishes the requirement for testing optical components or systems using a specified light source and a power meter to measure performance parameters such as signal strength or loss. In practice, this clause typically outlines the procedures for connecting the equipment, the conditions under which measurements are taken, and the acceptable performance thresholds. Its core function is to ensure that the tested components meet defined technical standards, thereby verifying quality and functionality before acceptance or deployment.
POPULAR SAMPLE Copied 1 times
Light Source and Power Meter Test. A bi-directional End to End test will be performed on each fiber in a span at 1550 nm with a Light Source and Power Meter. The purpose of this test is to determine actual span loss and to prove there is a one-to-one correspondence of all fibers. It is the SPC's responsibility to insure proper continuity of all fibers at the fiber level, not just the pigtail level. Any "frogs" or fibers that cross in the route will be remedied by SPC. The following span loss calculation will be used: (A * L) + (0.1 * N) + C = Acceptable Span Loss A = Attenuation per KM at 1550 nm L = Optical length of cable measured in kilometers (from OTDR Trace) N = Number of splices in a span C = Connector loss. The connector loss will not exceed .5dB. The section test will have (2) pigtail connectors/splices under test, so 1.0dB will be allowed for this loss. NOTE: STA MAY PROVIDE AN EXCEL SPREADSHEET FORMATED ON DISK FOR ENTRY OF TEST DATA. SPC WILL COMPLETE THE SPREADSHEET AND FORWARD TO STA.
Light Source and Power Meter Test. A bi-directional End-to-End test will be performed, as needed, on each fiber in a Span at 1550 nm with a Light Source and Power Meter. The purpose of this test is to determine actual Span loss and to prove there is a one-to-one correspondence of all fibers
Light Source and Power Meter Test. (A * L) + (0.1 * N) + C = Acceptable Span Loss A = Attenuation per KM at 1550 nm L = Optical length of cable measured in kilometers (from OTDR Trace) N = Number of splices in a span C = Connector loss. The connector loss will not exceed .5dB. The section test will have (2) pigtail connectors/splices under test, so 1.0dB will be allowed for this loss. NOTE: IXC CABLE ACCEPTANCE CAN PROVIDE AN EXCEL SPREADSHEET FORMATED ON DISK FOR ENTRY OF DATA