Common use of Input Register Configuration Clause in Contracts

Input Register Configuration. Each row of the configuration table is a unique data register having eight special attributes. REG FUNCTION -- Identifies the function of the register – Analog or Digital (Discrete) Note: If selecting the Digital (Discrete) function, be sure to set the appropriate Digital Capture Time (Page 15) XXX ADDRESS -- Assigns the address of the data register (0 to 99). GROUP NAME -- Assigns a group name to the data register (not used by XXX). Multiple data registers can have the same group name. This is useful for monitoring and data logging programs. POINT NAME -- Assigns a unique name to the data register to help identify the location of the sensor/transmitter (Not used by LON). Multiple point names can have the same group name. TRANSMITTER ID -- Assigns a wireless sensor/transmitter address to the data register. Each wireless sensor is factory configured with a unique hexadecimal address. TRANS CHAN -- Assigns a wireless sensor/transmitter data channel to the data register. A wireless sensor/transmitter may have up to four (4) analog channels and (4) digital status/alarm channels. DATA FORMAT LOG -- Assigns the data type to the register – temperature (RTD or Thermistor 20K), analog voltage, totalizer or humidity. This register is left blank if the REG FUNCTION is Digital (Discrete). -- Not used for MOD9200LON • First we will assign the REG FUNCTION by clicking in the REG FUNCTION cell to open a drop down menu. Select the appropriate function. • Use the mouse to move to the next column to assign the REG ADDRESS by clicking in the cell. Before entering register addresses, ensure the “RegisterEntry” AutoSet is turned off as shown: • The data registers of the MOD9200 should be assigned non-consecutively based on the network variable maps in Appendix A. User can assign specific data registers needed and skip to the next applicable data register using the Trs Programmer software setup tool. • Refer to Appendix A for REG ADDRESS to specific MO9200LON model. Either scroll to the appropriate address using the scroll bar or type the address in the cell and the drop down menu will automatically scroll to that address. Enter the Register address in the REG ADDRESS window and press down to enter. • Again use the mouse to move to the next column. Enter a GROUP NAME for the data set by typing the group name in the cell. Enter the name in the cell by using the mouse to click on the next column. Note: DO NOT use commas or semicolons in the Group Name. • Enter a POINT NAME for the data point by typing the name in the cell. Enter the name in the cell by using the mouse to click on the next column. Note: DO NOT use commas or semicolons in the Point Name. • Assign a sensor/transmitter to the data register by clicking in the TRANSMITTER ID cell to open a drop down menu. Use the scroll bar to scroll to the correct address or automatically scroll to the address by typing the hexadecimal address in the cell. To select the address, click on the appropriate ID in the drop down menu. Each ACI transmitter is factory configured with a unique ID – refer to the sensor product data sheet for the location of the transmitter ID. • Assign the appropriate sensor transmission channel to the data register by clicking in the cell to open a drop down menu. Click on the appropriate transmission channel (01 to 04) to select. The active transmission channels are factory configured as follows: Device Analog CH-01 Analog CH-02 Digital CH-01 WT2630A Space Temp (Therm 20K) WT2630B Space Temp (Therm 20K) SetPoint (Analog) Override (Discrete) See page 15 to set the Digital Capture Time WT2630C Space Temp (Therm 20K) Override (Discrete) See page 15 to set the Digital Capture Time WH2630A Humidity WH2630B Space Temp (Therm 20K) Humidity OA2630A Outdoor Temp (Therm 20K) Outdoor Humidity OST2630A Outdoor Temp (Therm 20K) DT2630A Duct Temperature (Therm 20K) DT2650A Ave Temperature (Therm 20K) DH2630A Duct Humidity DH2630B Duct Temperature (Therm 20K) Duct Humidity FT2630A Fluid Temperature (Therm 20K) RT2630A,B,C See Device Label for Analog (4) and Digital (4) Configuration RT2620A See Device Label for Digital (4) Configuration RT2602B Digital (2) Inputs SST2630A Temperature (Therm 20K) SST5630AE Temperature (RTD 1K) • Select the appropriate DATA FORMAT value by clicking in the cell to open a drop down menu. • To create a new data register row click on Row > Append. Continue to do this for each row/data register that needs to be configured. • The completed configuration example for an office building is as follows: • The columns may be resized by placing the cursor over one side of the column. When the cursor changes to two arrows, hold down the left mouse button and drag the side of the column to resize it.

Appears in 1 contract

Samples: pim.galco.com

AutoNDA by SimpleDocs

Input Register Configuration. Each row of the configuration table is a unique data register having eight 8 special attributes. REG FUNCTION -- Identifies the function of the register – Analog or Digital (Discrete) Note: If selecting the Digital (Discrete) function, function be sure to set the appropriate Digital Capture Time (Page 15) XXX ADDRESS -- Assigns the address of the data register (0 to 99). Automatically assigns the address of the error register (400 to 499 i.e. data register address + 400) GROUP NAME -- Assigns a group name to the data register (not used by XXX)register. Multiple data registers can have the same group name. This is useful for monitoring and data logging programs. POINT NAME -- Assigns a unique name to the data register to help identify the location of the sensor/transmitter (Not used by LON)transmitter. Multiple point names can have the same group name. TRANSMITTER ID -- Assigns a wireless sensor/transmitter address to the data register. Each wireless sensor is factory configured with a unique hexadecimal address. TRANS CHAN -- Assigns a wireless sensor/transmitter data channel to the data register. A wireless sensor/transmitter may have up to four (4) analog channels and (4) digital status/alarm channels. DATA FORMAT LOG -- Assigns the data type to the register – temperature (RTD or Thermistor 20K), analog voltage, totalizer or humidity. This register is left blank if the REG FUNCTION is Digital (Discrete). LOG -- Not Assigns the data register to a log file so the data can be logged over time. This field is only used for MOD9200LON when the gateway will be used with a data logging program such as SensorVuII • First we will assign the REG FUNCTION by clicking in the REG FUNCTION cell to open a drop down menu. Select the appropriate function. • Use the mouse to move to the next column to assign the REG ADDRESS by clicking in the cell. Before entering register addresses, ensure When the “RegisterEntry” RegisterEntry AutoSet is turned off as shown: • The data registers of the MOD9200 should be assigned non-consecutively based on the network variable maps in Appendix A. User can assign specific data registers needed and skip to on, REG ADDRESS is automatically filled with the next applicable data register using the Trs Programmer software setup tool. • Refer sequential number from 0 to Appendix A for REG ADDRESS to specific MO9200LON model. Either scroll to the appropriate address using the scroll bar or type the address in the cell and the drop down menu will automatically scroll to that address. Enter the Register address in the REG ADDRESS window and press down to enter99. • Again use the mouse to move to the next column. Enter a GROUP NAME for the data set by typing the group name in the cell. Enter the name in the cell by using the mouse to click on the next column. Note: DO NOT use commas or semicolons delimiters - , ; : < > [ ] { } ( ) / \ - in the Group Name. • Enter a POINT NAME for the data point by typing the name in the cell. Enter the name in the cell by using the mouse to click on the next column. Note: DO NOT use commas or semicolons delimiters in the Point Name. • Assign a sensor/transmitter to the data register by clicking in the TRANSMITTER ID cell to open a drop down menu. Use the scroll bar to scroll to the correct address or automatically scroll to the address by typing the hexadecimal address in the cell. To select the address, address click on the appropriate ID in the drop down menu. Each ACI transmitter is factory configured with a unique ID – refer to the sensor product data sheet for the location of the transmitter ID. • Assign the appropriate sensor transmission channel to the data register by clicking in the cell to open a drop down menu. Click on the appropriate transmission channel (01 to 04) to select. The active transmission channels are factory configured as follows: Device Analog CH-01 Analog CH-02 Digital CH-01 WT2630A Space Temp (Therm 20K) WT2630B Space Temp (Therm 20K) SetPoint (Analog) Override (Discrete) See page 15 to set the Digital Capture Time WT2630C Space Temp (Therm 20K) Override (Discrete) See page 15 to set the Digital Capture Time WH2630A WH2630A,C Humidity WH2630B WH2630B,D Space Temp (Therm 20K) Humidity OA2630A Outdoor Temp (Therm 20K) Outdoor Humidity OST2630A OT2630A Outdoor Temp (Therm 20K) DT2630A OH2630A Outdoor Humidity DT2630A,B Duct Temperature (Therm 20K) DT2650A Ave Temperature (Therm 20K) DH2630A DH2630A,D Duct Humidity DH2630B DH2630B,C,E,F Duct Temperature (Therm 20K) Duct Humidity FT2630A FT2630A,B Fluid Temperature (Therm 20K) CTM2630 Totalizer 01 Count – CH-03; Totalizer 02 Count – CH-04 RT2630A,B,C C,D See Device Label for Analog (4) and Digital (4) Configuration RT2620A RT2620A,B See Device Label for Digital (4) Configuration RT2602B Digital (2) Inputs SST2630A Temperature (Therm 20K) SST5630AE SST5630A Temperature (RTD 1K) • Select the appropriate DATA FORMAT value by clicking in the cell to open a drop down menu. • The LOG column is used to identify the file the register will be logged to when using SensorVuII Monitoring and Logging software. Enter the name of the appropriate “log file” specified in the SensorVuII LOG CONFIG menu. The file names are case sensitive. • To create a new data register row click on Row > Append. Continue to do this for each row/data register that needs to be configured. • The completed configuration example for an office building is as follows: • The columns may be resized by placing the cursor over one side of the column. When the cursor changes to two arrows, arrows hold down the left mouse button and drag the side of the column to resize it.

Appears in 1 contract

Samples: www.workaci.com:443

Input Register Configuration. Each row of the configuration table is a unique data register having eight 8 special attributes. REG FUNCTION XXX ADDRESS GROUP NAME POINT NAME TRANSMITTER ID TRANS CHAN DATA FORMAT LOG -- Identifies the function of the register – Analog or Digital (Discrete) Note: If selecting the Digital (Discrete) function, function be sure to set the appropriate Digital Capture Time (Page 15) XXX ADDRESS -- Assigns the address of the data register (0 to 99). GROUP NAME Automatically assigns the address of the error register (400 to 499 i.e. data register address + 400) -- Assigns a group name to the data register (not used by XXX)register. Multiple data registers can have the same group name. This is useful for monitoring and data logging programs. POINT NAME -- Assigns a unique name to the data register to help identify the location of the sensor/transmitter (Not used by LON)transmitter. Multiple point names can have the same group name. TRANSMITTER ID -- Assigns a wireless sensor/transmitter address to the data register. Each wireless sensor is factory configured with a unique hexadecimal address. TRANS CHAN -- Assigns a wireless sensor/transmitter data channel to the data register. A wireless sensor/transmitter may have up to four (4) analog channels and (4) digital status/alarm channels. DATA FORMAT LOG -- Assigns the data type to the register – temperature (RTD or Thermistor 20K), analog voltage, totalizer or humidity. This register is left blank if the REG FUNCTION is Digital (Discrete). -- Not used for MOD9200LON Obsolete Function. First First, we will assign the REG FUNCTION by clicking in the REG FUNCTION cell to open a drop down menu. Select the appropriate function. • Use the mouse to move to the next column to assign the REG ADDRESS by clicking in the cell. Before entering register addresses, ensure When the “RegisterEntry, AutoSetAutoSet is turned off as shown: • The data registers of the MOD9200 should be assigned non-consecutively based on the network variable maps in Appendix A. User can assign specific data registers needed and skip to on, REG ADDRESS is automatically filled with the next applicable data register using the Trs Programmer software setup toolsequential number from 0 to 99. • Refer to Appendix A for REG ADDRESS to specific MO9200LON model. Either scroll to the appropriate address using the scroll bar or type the address in the cell and the drop down menu will automatically scroll to that address. Enter the Register address in the REG ADDRESS window and press down to enter. • Again Again, use the mouse to move to the next column. Enter a GROUP NAME for the data set by typing the group name in the cell. Enter the name in the cell by using the mouse to click on the next column. Note: DO NOT use commas or semicolons delimiters - , ; : < > [ ] { } ( ) / \ - in the Group Name. • Enter a POINT NAME for the data point by typing the name in the cell. Enter the name in the cell by using the mouse to click on the next column. Note: DO NOT use commas or semicolons delimiters in the Point Name. • Assign a sensor/transmitter to the data register by clicking in the TRANSMITTER ID cell to open a drop drop-down menu. Use the scroll bar to scroll to the correct address or automatically scroll to the address by typing the hexadecimal address in the cell. To select the address, click on the appropriate ID in the drop drop-down menu. Each ACI transmitter is factory configured with a unique ID – refer to the sensor product data sheet for the location of the transmitter ID. • Assign the appropriate sensor transmission channel to the data register by clicking in the cell to open a drop drop-down menu. Click on the appropriate transmission channel (01 to 04) to select. The active transmission channels are factory configured as follows: Device Analog CH-01 Analog CH-02 Digital CH-01 WT2630A Space Temp (Therm 20K) WT2630B Space Temp (Therm 20K) SetPoint (Analog) Override (Discrete) See page 15 to set the Digital Capture Time WT2630C Space Temp (Therm 20K) Override (Discrete) See page 15 to set the Digital Capture Time WH2630A Humidity WH2630B Space Temp (Therm 20K) Humidity OA2630A Outdoor Temp (Therm 20K) Outdoor Humidity OST2630A Outdoor Temp (Therm 20K) DT2630A Duct Temperature (Therm 20K) DT2650A Ave Temperature (Therm 20K) DH2630A Duct Humidity DH2630B Duct Temperature (Therm 20K) Duct Humidity FT2630A Fluid Temperature (Therm 20K) RT2630A,, B,, C See Device Label for Analog (4) and Digital (4) Configuration RT2620A See Device Label for Digital (4) Configuration RT2602B Digital (2) Inputs SST2630A Temperature (Therm 20K) SST5630AE Temperature (RTD 1K) • Select the appropriate DATA FORMAT value by clicking in the cell to open a drop drop-down menu. • To create a new data register row row, click on Row > Append. Continue to do this for each row/data register that needs to be configured. • The completed configuration example for an office building is as follows: • The columns may be resized by placing the cursor over one side of the column. When the cursor changes to two arrows, arrows hold down the left mouse button and drag the side of the column to resize it.

Appears in 1 contract

Samples: www.workaci.com:443

Input Register Configuration. Each row of the configuration table is a unique data register having eight special attributes. REG FUNCTION -- Identifies the function of the register – Analog or Digital (Discrete) Note: If selecting the Digital (Discrete) function, be sure to set the appropriate Digital Capture Time (Page 15) XXX ADDRESS -- Assigns the address of the data register (0 to 99). GROUP NAME -- Assigns a group name to the data register (not used by XXX). Multiple data registers can have the same group name. This is useful for monitoring and data logging programs. POINT NAME -- Assigns a unique name to the data register to help identify the location of the sensor/transmitter (Not used by LON). Multiple point names can have the same group name. TRANSMITTER ID -- Assigns a wireless sensor/transmitter address to the data register. Each wireless sensor is factory configured with a unique hexadecimal address. TRANS CHAN -- Assigns a wireless sensor/transmitter data channel to the data register. A wireless sensor/transmitter may have up to four (4) analog channels and (4) digital status/alarm channels. DATA FORMAT LOG -- -- Assigns the data type to the register – temperature (RTD or Thermistor 20K), analog voltage, totalizer or humidity. This register is left blank if the REG FUNCTION is Digital (Discrete). -- Not used for MOD9200LON • First First, we will assign the REG FUNCTION by clicking in the REG FUNCTION cell to open a drop drop-down menu. Select the appropriate function. • Use the mouse to move to the next column to assign the REG ADDRESS by clicking in the cell. Before entering register addresses, ensure the “RegisterEntry” AutoSet Auto Set is turned off as shown: • The data registers of the MOD9200 should be assigned non-consecutively based on the network variable maps in Appendix A. User can assign specific data registers needed and skip to the next applicable data register using the Trs Programmer software setup tool. • Refer to Appendix A for REG ADDRESS to specific MO9200LON model. Either scroll to the appropriate address using the scroll bar or type the address in the cell and the drop drop-down menu will automatically scroll to that address. Enter the Register address in the REG ADDRESS window and press down to enter. • Again Again, use the mouse to move to the next column. Enter a GROUP NAME for the data set by typing the group name in the cell. Enter the name in the cell by using the mouse to click on the next column. Note: DO NOT use commas or semicolons in the Group Name. • Enter a POINT NAME for the data point by typing the name in the cell. Enter the name in the cell by using the mouse to click on the next column. Note: DO NOT use commas or semicolons in the Point Name. • Assign a sensor/transmitter to the data register by clicking in the TRANSMITTER ID cell to open a drop drop-down menu. Use the scroll bar to scroll to the correct address or automatically scroll to the address by typing the hexadecimal address in the cell. To select the address, click on the appropriate ID in the drop drop-down menu. Each ACI transmitter is factory configured with a unique ID – refer to the sensor product data sheet for the location of the transmitter ID. • Assign the appropriate sensor transmission channel to the data register by clicking in the cell to open a drop drop-down menu. Click on the appropriate transmission channel (01 to 04) to select. The active transmission channels are factory configured as follows: Device Analog CH-01 Analog CH-02 Digital CH-01 WT2630A Space Temp (Therm 20K) WT2630B Space Temp (Therm 20K) SetPoint (Analog) Override (Discrete) See page 15 to set the Digital Capture Time WT2630C Space Temp (Therm 20K) Override (Discrete) See page 15 to set the Digital Capture Time WH2630A Humidity WH2630B Space Temp (Therm 20K) Humidity OA2630A Outdoor Temp (Therm 20K) Outdoor Humidity OST2630A Outdoor Temp (Therm 20K) DT2630A Duct Temperature (Therm 20K) DT2650A Ave Temperature (Therm 20K) DH2630A Duct Humidity DH2630B Duct Temperature (Therm 20K) Duct Humidity FT2630A Fluid Temperature (Therm 20K) RT2630A,, B,, C See Device Label for Analog (4) and Digital (4) Configuration RT2620A See Device Label for Digital (4) Configuration RT2602B Digital (2) Inputs SST2630A Temperature (Therm 20K) SST5630AE Temperature (RTD 1K) • Select the appropriate DATA FORMAT value by clicking in the cell to open a drop drop- down menu. • To create a new data register row row, click on Row > Append. Continue to do this for each row/data register that needs to be configured. • The completed configuration example for an office building is as follows: • The columns may be resized by placing the cursor over one side of the column. When the cursor changes to two arrows, hold down the left mouse button and drag the side of the column to resize it.

Appears in 1 contract

Samples: www.workaci.com:443

AutoNDA by SimpleDocs

Input Register Configuration. Each row of the configuration table is a unique data register having eight 8 special attributes. REG FUNCTION XXX ADDRESS GROUP NAME POINT NAME TRANSMITTER ID TRANS CHAN DATA FORMAT LOG -- Identifies the function of the register – Analog or Digital (Discrete) Note: If selecting the Digital (Discrete) function, function be sure to set the appropriate Digital Capture Time (Page 15) XXX ADDRESS -- Assigns the address of the data register (0 to 99). GROUP NAME Automatically assigns the address of the error register (400 to 499 i.e. data register address + 400) -- Assigns a group name to the data register (not used by XXX)register. Multiple data registers can have the same group name. This is useful for monitoring and data logging programs. POINT NAME -- Assigns a unique name to the data register to help identify the location of the sensor/transmitter (Not used by LON)transmitter. Multiple point names can have the same group name. TRANSMITTER ID -- Assigns a wireless sensor/transmitter address to the data register. Each wireless sensor is factory configured with a unique hexadecimal address. TRANS CHAN -- Assigns a wireless sensor/transmitter data channel to the data register. A wireless sensor/transmitter may have up to four (4) analog channels and (4) digital status/alarm channels. DATA FORMAT LOG -- Assigns the data type to the register – temperature (RTD or Thermistor 20K), analog voltage, totalizer or humidity. This register is left blank if the REG FUNCTION is Digital (Discrete). -- Not used for MOD9200LON Obsolete Function. • First we will assign the REG FUNCTION by clicking in the REG FUNCTION cell to open a drop down menu. Select the appropriate function. • Use the mouse to move to the next column to assign the REG ADDRESS by clicking in the cell. Before entering register addresses, ensure When the “RegisterEntry, AutoSetAutoSet is turned off as shown: • The data registers of the MOD9200 should be assigned non-consecutively based on the network variable maps in Appendix A. User can assign specific data registers needed and skip to on, REG ADDRESS is automatically filled with the next applicable data register using the Trs Programmer software setup tool. • Refer sequential number from 0 to Appendix A for REG ADDRESS to specific MO9200LON model. Either scroll to the appropriate address using the scroll bar or type the address in the cell and the drop down menu will automatically scroll to that address. Enter the Register address in the REG ADDRESS window and press down to enter99. • Again use the mouse to move to the next column. Enter a GROUP NAME for the data set by typing the group name in the cell. Enter the name in the cell by using the mouse to click on the next column. Note: DO NOT use commas or semicolons delimiters - , ; : < > [ ] { } ( ) / \ - in the Group Name. • Enter a POINT NAME for the data point by typing the name in the cell. Enter the name in the cell by using the mouse to click on the next column. Note: DO NOT use commas or semicolons delimiters in the Point Name. • Assign a sensor/transmitter to the data register by clicking in the TRANSMITTER ID cell to open a drop down menu. Use the scroll bar to scroll to the correct address or automatically scroll to the address by typing the hexadecimal address in the cell. To select the address, click on the appropriate ID in the drop down menu. Each ACI transmitter is factory configured with a unique ID – refer to the sensor product data sheet for the location of the transmitter ID. • Assign the appropriate sensor transmission channel to the data register by clicking in the cell to open a drop down menu. Click on the appropriate transmission channel (01 to 04) to select. The active transmission channels are factory configured as follows: Device Analog CH-01 Analog CH-02 Digital CH-01 WT2630A Space Temp (Therm 20K) WT2630B Space Temp (Therm 20K) SetPoint (Analog) Override (Discrete) See page 15 to set the Digital Capture Time WT2630C Space Temp (Therm 20K) Override (Discrete) See page 15 to set the Digital Capture Time WH2630A Humidity WH2630B Space Temp (Therm 20K) Humidity OA2630A Outdoor Temp (Therm 20K) Outdoor Humidity OST2630A Outdoor Temp (Therm 20K) DT2630A Duct Temperature (Therm 20K) DT2650A Ave Temperature (Therm 20K) DH2630A Duct Humidity DH2630B Duct Temperature (Therm 20K) Duct Humidity FT2630A Fluid Temperature (Therm 20K) RT2630A,B,C See Device Label for Analog (4) and Digital (4) Configuration RT2620A See Device Label for Digital (4) Configuration RT2602B Digital (2) Inputs SST2630A Temperature (Therm 20K) SST5630AE Temperature (RTD 1K) • Select the appropriate DATA FORMAT value by clicking in the cell to open a drop down menu. • To create a new data register row row, click on Row > Append. Continue to do this for each row/data register that needs to be configured. • The completed configuration example for an office building is as follows: • The columns may be resized by placing the cursor over one side of the column. When the cursor changes to two arrows, arrows hold down the left mouse button and drag the side of the column to resize it.

Appears in 1 contract

Samples: www.workaci.com