Common use of Information Reporting Obligations Clause in Contracts

Information Reporting Obligations. 3.8.1 In order to provide Interconnection Service hereunder, Pepco may request, and Generator shall promptly provide, all relevant information, documents, or data regarding the Generating Facilities that would be expected to materially affect the Transmission System, and which is reasonably requested by NERC, MAAC, the PJM Interconnection LLC, the MDPSC, the District of Columbia Public Service Commission and any other state or District of Columbia agency having jurisdiction over Pepco or Generator, the PJM System Operator, or the Transmission Operator, which disclosure shall be subject to Article 6 of this Agreement regarding the disclosure of commercially sensitive information. 3.8.2 Generator shall promptly supply accurate, complete, and reliable information in response to reasonable information requests for real time data and other data from Pepco necessary for operations, maintenance, compliance with PJM Requirements or regulatory requirements, or analysis of the Interconnection Facilities or the Transmission System. Such information may include metered values for MW and MVAR, voltage, current, automatic voltage regulator status, automatic frequency control, dispatch, frequency, breaker status indication, or any other information reasonably required for reliable operation of the Transmission System pursuant to PJM Requirements and Good Utility Practice. At minimum, Generator shall satisfy the telemetry requirements set forth in Schedule H. 3.8.3 Information pertaining to generation operating parameters shall be gathered and electronically transmitted directly to Pepco's energy management system using a mutually acceptable communications protocol. 3.8.4 Generator shall be responsible for the maintenance, and any required replacements or upgrades of the field devices and equipment used to gather information regarding generation operating parameters. 3.8.5 Generator shall Maintain, at its expense, operating telephone links to the PJM Interconnection LLC, PJM System Operator, Pepco and the Transmission Operator, to provide information deemed necessary by them, or as reasonably deemed necessary by Pepco in accordance with PJM Requirements or Good Utility Practice to integrate operation of the Station with the Transmission System, provided, however, that Generator shall not be obligated under this ----------------- Agreement to modernize, expand or upgrade the Generator's facilities unless the failure to modernize, expand or upgrade is reasonably likely to have a material adverse effect on the operation of the Transmission System. Generator shall use communication links at the Station consisting of the mobile radio low band C frequency and "all call" and "red phone" systems currently located at the Station (or successor systems as may reasonably be required by Pepco) and shall maintain the availability of such systems to operate during abnormal conditions including blackouts.

Appears in 1 contract

Sources: Interconnection Agreement (Mirant Mid Atlantic LLC)

Information Reporting Obligations. 3.8.1 In order to provide Interconnection Service hereunder, Pepco may request, and Generator shall promptly provide, all relevant information, documents, or data regarding the Generating Facilities that would be expected to materially affect the Transmission System, and which is reasonably requested by NERC, MAAC, the PJM Interconnection LLC, the MDPSC, the District of Columbia Public Service Commission and any other state or District of Columbia agency having jurisdiction over Pepco or Generator, the PJM System Operator, or the Transmission Operator, which disclosure shall be subject to Article 6 of this Agreement regarding the disclosure of commercially sensitive information. 3.8.2 Generator shall promptly supply accurate, complete, and reliable information in response to reasonable information requests for real time data and other data from Pepco necessary for operations, maintenance, compliance with PJM Requirements or regulatory requirements, or analysis of the Interconnection Facilities or the Transmission System. Such information may include metered values for MW and MVAR, voltage, current, automatic voltage regulator status, automatic frequency control, dispatch, frequency, breaker status indication, or any other information reasonably required for reliable operation of the Transmission System pursuant to PJM Requirements and Good Utility Practice. At minimum, Generator shall satisfy the telemetry requirements set forth in Schedule H. 3.8.3 Information pertaining to generation operating parameters shall be gathered and electronically transmitted directly to Pepco's energy management system using a mutually acceptable communications protocol. 3.8.4 Generator shall be responsible for the maintenance, and any required replacements or upgrades of the field devices and equipment used to gather information regarding generation operating parameters. 3.8.5 Generator shall Maintain, at its expense, operating telephone links to the PJM Interconnection LLC, PJM System Operator, Pepco and the Transmission Operator, to provide information deemed necessary by them, or as reasonably deemed necessary by Pepco in accordance with PJM Requirements or Good Utility Practice to integrate operation of the Station with the Transmission System, provided, however, that Generator shall not be obligated under this ----------------- Agreement to modernize, expand or upgrade the Generator's facilities unless the failure to modernize, expand or upgrade is reasonably likely to have a material adverse effect on the operation of the Transmission System. Generator shall use communication links at the Station consisting of the mobile radio low band C frequency and "all call" and "red phone" systems currently located at the Station (or successor systems as may reasonably be required by Pepco) and shall maintain the availability of such systems to operate during abnormal conditions including blackouts.

Appears in 1 contract

Sources: Asset Purchase and Sale Agreement (Potomac Electric Power Co)

Information Reporting Obligations. 3.8.1 3.6.1 In order to provide maintain Interconnection Service hereunderService, Pepco the Switching Station Owners may request, and Generator the Generating Station Owners shall promptly provide, all relevant information, documents, or data regarding the Generating Facilities Conemaugh Station that would be expected to materially affect the Transmission System, and which is reasonably requested by NERC, MAAC, the PJM Interconnection LLCInterconnection, L.L.C., the MDPSCPAPUC, the District of Columbia Public Service Commission and any other state or District of Columbia agency having jurisdiction over Pepco the Switching Station Owners or Generatorthe Generating Station Owners or any one or more of them, the PJM System Operator, or the Transmission Operator, which disclosure shall be subject to Article 6 of this Agreement reasonable restrictions, acceptable to the Switching Station Owners and the Generating Station Owners, regarding the disclosure of commercially sensitive informationinformation provided by the Generating Station Owners. 3.8.2 Generator 3.6.2 The Generating Station Owners shall promptly supply accurate, complete, and reliable information in response to reasonable information requests for real time data and other data from Pepco necessary for operations, maintenance, compliance with PJM Requirements or regulatory requirements, or and analysis of the Interconnection Facilities Transmission System which is reasonably requested by NERC, MAAC, PJM Interconnection, L.L.C., the PAPUC, any other state or District of Columbia agency having jurisdiction over the Switching Station Owners or the Generating Station Owners or any one or more of them, the PJM System Operator, or the Transmission SystemOperator, which disclosure shall be subject to reasonable restrictions, acceptable to the Switching Station Owners and the Generating Station Owners, regarding the disclosure of commercially sensitive information provided by the Generating Station Owners. Such information may include metered values for MW and MVAR, voltage, current, amperage, automatic voltage regulator status, automatic frequency control, dispatch, frequency, breaker status indication, or any other information reasonably required for reliable operation of the Transmission System pursuant to 18 applicable law, PJM Requirements requirements and Good Utility Practice. At minimum, Generator shall satisfy the telemetry requirements set forth in Schedule H.. 3.8.3 3.6.3 Information pertaining to generation operating parameters shall be gathered for electronic transmittal to the Switching Station Owners and electronically transmitted directly provided to Pepco's energy management system using a mutually acceptable communications protocol.the Switching Station Owners Remote Terminal Units (RTUs) in accordance with Schedule A. 3.8.4 Generator 3.6.4 The Generating Station Owners shall be responsible for the maintenance, and any required replacements or upgrades of the field devices and equipment used to gather information regarding generation operating parameters. 3.8.5 Generator 3.6.5 The Generating Station Owners shall Maintain, at its their own expense, operating telephone links to the PJM Interconnection LLCInterconnection, L.L.C., PJM System Operator, Pepco and the or Transmission Operator, to provide information deemed necessary by them, or as reasonably deemed necessary by Pepco the Switching Station Owners in accordance with PJM Requirements applicable law or Good Utility Practice to integrate operation of the Conemaugh Station with the Transmission System, System provided, however, that Generator the Generation Station Owners shall not be obligated under this ----------------- Agreement to modernize, expand or upgrade the Generator's facilities Generation Station Owners' Facilities unless the failure to modernize, expand or upgrade is reasonably likely to have a an material adverse effect impact on the operation of the Transmission System. Generator shall use communication links at the Station consisting of the mobile radio low band C frequency and "all call" and "red phone" systems currently located at the Station (or successor systems as may reasonably be required by Pepco) and shall maintain the availability of such systems to operate during abnormal conditions including blackouts.

Appears in 1 contract

Sources: Interconnection Agreement (Reliant Energy Mid Atlantic Power Services Inc)