Downlink Transmission Model. ‌ 1k Nk Let denote the aggregate beamformer from all RRHs towards the k-th IT as wk = [wH , · · · , wH ]H ∈ CMN×1, where wnk ∈ CM×1 is the beamforming vector from the n-th RRH to the k-th IT, k ∈ Li. Similarly, the aggregate channel between all RRHs 1k Nk and the k-th IT is denoted as hk = [hH , · · · , hH ]H ∈ CMN×1, where hnk ∈ CM×1 is the channel vector between the n-th RRH and the k-th IT, k ∈ Li. The received signal at the k-th IT, k ∈ Li is given by zk = hHwksk + ∑ hHw js j + nk, ∀k ∈ Li (3.3) k k
AutoNDA by SimpleDocs
Downlink Transmission Model. ‌ 1i Ni The aggregate beamforming vector from all the RRHs towards the i-th IT, i ∈ Li, as wi = [wH,··· , wH ]H ∈ CMN×1 is denoted, where wni ∈ CM×1 is the beamformer 1e Ne from the n-th RRH towards the i-th IT. ve = [vH , · · · , vH ]H ∈ CMN×1 represents the aggregate beamforming vector from all the RRHs to the e-th active ET. Similarly, let hni ∈ CM×1 represent the channel vector between the n-th RRH and the i-th IT, the aggregate channel vector between all the RRHs and the i-th IT is denoted by hi = [hH,··· , hH ]H ∈ CMN×1. The received signals at the i-th IT, i ∈ Li, is then 1i given by Ni yi = hH wis[IT] + ∑ hH w js[IT] + ∑ hHves[ET] + ni, (4.1) j/=i ∈Xx

Related to Downlink Transmission Model

  • Data Transmission The procedures for transmitting load obligation data to PJM for DS Supplier’s DS Load shall be as set forth by PJM.

  • Data Transmission Control Except as necessary for the provision of the Cloud Services in accordance with the Agreement, Personal Data must not be read, copied, modified or removed without authorization during transfer. Where data carriers are physically transported, adequate measures are implemented at SAP to provide the agreed-upon service levels (for example, encryption and lead-lined containers). Measures: • Personal Data in transfer over SAP internal networks is protected according to SAP Security Policy. • When data is transferred between SAP and its customers, the protection measures for the transferred Personal Data are mutually agreed upon and made part of the relevant agreement. This applies to both physical and network based data transfer. In any case, the Customer assumes responsibility for any data transfer once it is outside of SAP-controlled systems (e.g. data being transmitted outside the firewall of the SAP Data Center).

  • Loop Transmission Types 3.1 Subject to the conditions set forth in Section 1 of this Attachment, Verizon shall allow CBB to access Loops unbundled from local switching and local transport, in accordance with this Section 3 and the rates and charges provided in the Pricing Attachment. Verizon shall allow CBB access to Loops in accordance with, but only to extent required by, Applicable Law. The available Loop types are as set forth below:

  • Interoffice Transmission Facilities BellSouth shall provide nondiscriminatory access, in accordance with FCC Rule 51.311 and Section 251(c)(3) of the Act, to interoffice transmission facilities on an unbundled basis to <<customer_name>> for the provision of a telecommunications service.

  • Information Transmission The Provider, on behalf of itself and its respective Subsidiaries, shall use commercially reasonable efforts to provide or make available, or cause to be provided or made available, to the Recipient, in accordance with Section 6.1 of the Separation and Distribution Agreement, any Information received or computed by the Provider for the benefit of the Recipient concerning the relevant Service during the Service Period; provided, however, that, except as otherwise agreed to in writing by the Parties (a) the Provider shall not have any obligation to provide, or cause to be provided, Information in any non-standard format, (b) the Provider and its Subsidiaries shall be reimbursed for their reasonable costs in accordance with Section 6.3 of the Separation and Distribution Agreement for creating, gathering, copying, transporting and otherwise providing such Information, and (c) the Provider shall use commercially reasonable efforts to maintain any such Information in accordance with Section 6.4 of the Separation and Distribution Agreement.

  • Signaling Link Transport 9.2.1 Signaling Link Transport is a set of two or four dedicated 56 kbps transmission paths between Global Connection-designated Signaling Points of Interconnection that provide appropriate physical diversity.

  • Interconnection Service Interconnection Service allows the Interconnection Customer to connect the Large Generating Facility to the Participating TO’s Transmission System and be eligible to deliver the Large Generating Facility’s output using the available capacity of the CAISO Controlled Grid. To the extent the Interconnection Customer wants to receive Interconnection Service, the Participating TO shall construct facilities identified in Appendices A and C that the Participating TO is responsible to construct. Interconnection Service does not necessarily provide the Interconnection Customer with the capability to physically deliver the output of its Large Generating Facility to any particular load on the CAISO Controlled Grid without incurring congestion costs. In the event of transmission constraints on the CAISO Controlled Grid, the Interconnection Customer's Large Generating Facility shall be subject to the applicable congestion management procedures in the CAISO Tariff in the same manner as all other resources.

  • Transmission The Custodian and the Fund shall comply with SWIFT’s authentication procedures. The Custodian will act on FT Instructions received via SWIFT provided the instruction is authenticated by the SWIFT system. § Written Instructions. Instructions may be transmitted in an original writing that bears the manual signature of an Authorized Person(s).

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • No Transmission Service The execution of this LGIA does not constitute a request for, nor the provision of, any transmission service under the CAISO Tariff, and does not convey any right to deliver electricity to any specific customer or point of delivery.