Common use of Descriptions Clause in Contracts

Descriptions. Descriptions of bolts shall be deemed to include nuts and washers Descriptions of expansion anchors and bolts and chemical anchors and bolts shall be deemed to include nuts, washers and mortices in brickwork or concrete Metalwork described as"holed for bolt(s)" shall be deemed to exclude the bolts unless otherwise described Drawings Tenderers are referred to architect's drawings annexed to this document for full details of the windows, doors, etc ALUMINIUM WINDOWS, DOORS, ETC AAAMSA guide All windows, doors, etc shall comply with and meet the minimum recommended performance requirements as set out in the General Specification for Architectural Aluminium and Glass Products (Third Edition) as published by the Association of Architectural Aluminium Manufacturers of South Africa (AAAMSA) Carried to Collection R Finish The windows, doors, etc shall be natural anodised to a thickness of 25 micron and shall comply with SABS 999 and 1407 Glass Glazing to be with patent rubber gaskets with glazing beads and comply with BS 952. Thickness of glass shall be in accordance with table 1 (Part N : Glazing ). Safety glass shall comply with SABS 1263. The National Building Regulations shall be observed with regard to the specification of safety glass Design indemnity The contractor is to submit with his tender the "Form of Indemnity", annexed to this document, fully completed and signed Drawings Tenderers are referred to architect's drawings annexed to these bills of quantities for full details of windows, doors, etc Pricing. All window prices should include alluminium louvres as shown General Workshop drawings to be approved by the architect before manufacture PRESSED STEEL DOOR FRAMES Carried to Collection R "Nty" doors 31 "Code 914" door frame size 914 x 2032mm high fitted with three (3) parliament hinges, complete with single security gate size 914 x 2032mm high overall formed of 25 x 25 x 2mm tubular section frame mitred and welded at angles and two 25 x 25 x 2mm tubular section horizontal middle rails, gate filled in with 12 x 12 x 12mm square section vertical rails at 100mm centres and fitted with locking bolt for padlock, frame formed of 25 x 38 x 2mm tubular section xxxxxx and top rail mitred and welded at angles and fitted with three hinges welded to gate and frame, frame factory welded at maximum 250mm centres to door frame No 2 PLASTERING SCREEDS Screeds on concrete 32 20mm Thick on floors m2 227 INTERNAL PLASTER Cement plaster on brickwork 33 On walls m2 164 34 On narrow widths m2 10 EXTERNAL PLASTER Cement plaster on brickwork 35 On walls TILING m2 230 SUPPLEMENTARY PREAMBLES Descriptions Unless described as "fixed with adhesive to plaster (plaster elsewhere)" descriptions of tiling on brick or concrete walls, columns, etc shall be deemed to include 1:4 cement plaster backing and descriptions of tiling on concrete floors etc shall be deemed to include 1:3 plaster bedding Carried to Collection R FLOOR TILING 420 x 420 11.5mm kilimanjaro floor tiles or similar approved by architects, fixed with adhesive, painted with tinted waterproof jointing compound. Grouting to be grey, tiles 36 On floors and landings m2 227 37 Skirting formed of cut kilimanjaro floor tile - cut to 420 x 75mm high.

Appears in 1 contract

Samples: www.idt.org.za

AutoNDA by SimpleDocs

Descriptions. Descriptions of bolts shall be deemed to include nuts and washers Descriptions of expansion anchors and bolts and chemical anchors and bolts shall be deemed to include nuts, washers and mortices in brickwork or concrete Metalwork described as"holed for bolt(s)" shall be deemed to exclude the bolts unless otherwise described Drawings Tenderers are referred to architect's drawings annexed to this document for full details of the windows, doors, etc ALUMINIUM WINDOWS, DOORS, ETC AAAMSA guide All windows, doors, etc shall comply with and meet the minimum recommended performance requirements as set out in the General Specification for Architectural Aluminium and Glass Products (Third Edition) as published by the Association of Architectural Aluminium Manufacturers of South Africa (AAAMSA) Carried to Collection R Finish The windows, doors, etc shall be natural anodised to a thickness of 25 micron and shall comply with SABS 999 and 1407 Glass Glazing to be with patent rubber gaskets with glazing beads and comply with BS 952. Thickness of glass shall be in accordance with table 1 (Part N : Glazing ). Safety glass shall comply with SABS 1263. The National Building Regulations shall be observed with regard to the specification of safety glass Design indemnity The contractor is to submit with his tender the "Form of Indemnity", annexed to this document, fully completed and signed Drawings Tenderers are referred to architect's drawings annexed to these bills of quantities for full details of windows, doors, etc Pricing. All window prices should include alluminium louvres as shown General Workshop drawings to be approved by the architect before manufacture PRESSED STEEL DOOR FRAMES Carried to Collection R "Nty" doors 31 30 "Code 914" door frame size 914 x 2032mm high fitted with three (3) parliament hinges, complete with single security gate size 914 x 2032mm high overall formed of 25 x 25 x 2mm tubular section frame mitred and welded at angles and two 25 x 25 x 2mm tubular section horizontal middle rails, gate filled in with 12 x 12 x 12mm square section vertical rails at 100mm centres and fitted with locking bolt for padlock, frame formed of 25 x 38 x 2mm tubular section xxxxxx and top rail mitred and welded at angles and fitted with three hinges welded to gate and frame, frame factory welded at maximum 250mm centres to door frame No 2 PLASTERING SCREEDS Screeds on concrete 32 20mm Thick on floors m2 227 INTERNAL PLASTER Cement plaster on brickwork 33 On walls m2 164 34 On narrow widths m2 10 EXTERNAL PLASTER Cement plaster on brickwork 35 On walls TILING m2 230 SUPPLEMENTARY PREAMBLES Descriptions Unless described as "fixed with adhesive to plaster (plaster elsewhere)" descriptions of tiling on brick or concrete walls, columns, etc shall be deemed to include 1:4 cement plaster backing and descriptions of tiling on concrete floors etc shall be deemed to include 1:3 plaster bedding Carried to Collection R FLOOR TILING 420 x 420 11.5mm kilimanjaro floor tiles or similar approved by architects, fixed with adhesive, painted with tinted waterproof jointing compound. Grouting to be grey, tiles 36 On floors and landings m2 227 37 Skirting formed of cut kilimanjaro floor tile - cut to 420 x 75mm high.2

Appears in 1 contract

Samples: www.idt.org.za

Descriptions. Descriptions of bolts Items described as "nailed" shall be deemed to be fixed with hardened steel nails or pins or shot pinned to brickwork or concrete Items described as "plugged" shall be deemed to include nuts screwing to fibre, plastic or metal plugs at not exceeding 600mm centres, and washers Descriptions of expansion anchors and bolts and chemical anchors and bolts shall be deemed to include nuts, washers and mortices in brickwork or concrete Metalwork described as"holed for bolt(s)" shall be deemed to exclude the bolts unless otherwise described Drawings Tenderers are referred to architect's drawings annexed to this document for full details of the windows, doors, etc ALUMINIUM WINDOWS, DOORS, ETC AAAMSA guide All windows, doors, etc shall comply with and meet the minimum recommended performance requirements as set out in the General Specification for Architectural Aluminium and Glass Products (Third Edition) as published by the Association of Architectural Aluminium Manufacturers of South Africa (AAAMSA) Carried to Collection R Finish The windows, doors, etc shall be natural anodised to a thickness of 25 micron and shall comply with SABS 999 and 1407 Glass Glazing to be with patent rubber gaskets with glazing beads and comply with BS 952. Thickness of glass shall be in accordance with table 1 (Part N : Glazing ). Safety glass shall comply with SABS 1263. The National Building Regulations shall be observed with regard to the specification of safety glass Design indemnity The contractor is to submit with his tender the "Form of Indemnity", annexed to this document, fully completed and signed Drawings Tenderers are referred to architect's drawings annexed to these bills of quantities for full details of windows, doors, etc Pricing. All window prices should include alluminium louvres as shown General Workshop drawings to be approved by the architect before manufacture PRESSED STEEL DOOR FRAMES Carried to Collection R "Nty" doors 31 "Code 914" door frame size 914 x 2032mm high fitted with three (3) parliament hinges, complete with single security gate size 914 x 2032mm high overall formed of 25 x 25 x 2mm tubular section frame mitred and welded at angles and two 25 x 25 x 2mm tubular section horizontal middle rails, gate filled in with 12 x 12 x 12mm square section vertical rails at 100mm centres and fitted with locking bolt for padlock, frame formed of 25 x 38 x 2mm tubular section xxxxxx and top rail mitred and welded at angles and fitted with three hinges welded to gate and frame, frame factory welded at maximum 250mm centres to door frame No 2 PLASTERING SCREEDS Screeds on concrete 32 20mm Thick on floors m2 227 INTERNAL PLASTER Cement plaster on brickwork 33 On walls m2 164 34 On narrow widths m2 10 EXTERNAL PLASTER Cement plaster on brickwork 35 On walls TILING m2 230 SUPPLEMENTARY PREAMBLES Descriptions Unless where described as "fixed bolted" the bolts have been given elsewhere Bulkheads Bulkheads are those areas of the ceiling which are at a level differing from the general ceiling in a particular room or area and which generally occur along the perimeter of the room or area. Their purpose is either to conceal services or to create an architectural feature by changing levels. Bulkheads will only be measured as such when they conform with adhesive the above description and when the horizontal or vertical dimensions do not exceed 1,2m. Should these dimensions be more than 1,2m then the horizontal or vertical ceilings will be included in the general ceiling measurements. INSULATION Approved type mineral wool ceiling insulation in blanket form laid in single thickness 1 140mm Insulation nailed to plaster (plaster elsewhere)underside of ceilings m2 861 CEILINGS ETC NAILED UP CEILINGS 6,4mm Thick "Rhino" descriptions of tiling on brick or concrete walls, columns, etc shall be deemed to include 1:4 cement plaster backing and descriptions of tiling on concrete floors etc shall be deemed to include 1:3 plaster bedding Carried to Collection R FLOOR TILING 420 x 420 11.5mm kilimanjaro floor tiles or similar approved by architects, gypsum plasterboard ceiling with 63mm wide strips of mesh scrim nailed over joints and the whole finished with 6mm thick gypsum skim plaster to a smooth polished surface as per the manufacturers specification 2 Ceilings including 38 x 38 mm sawn softwood brandering fixed with adhesive, painted with tinted waterproof jointing compound. Grouting to be grey, tiles 36 On floors and landings steel at 400 mm centres m2 227 37 Skirting formed of cut kilimanjaro floor tile - cut to 420 x 170 "Rhino" gypsum plasterboard cornices 3 75mm high.Coved cornices m 46 Sundries 4 Extra over ceiling for opening for 1 700 x 1 200mm No 5 5 Extra over ceiling for opening for 550 x 4 000mm No 15 SUSPENDED CEILINGS Pre-painted 1200 x 600 x 9mm "Lafarge gypsum" or similar approved acoustic lay-in ceilings on "Xxxx" pre-painted exposed tee suspension system including main and cross tees, necessary hangers, grids, etc 6 Ceilings suspended not exceeding 1m below steel trusses and concrete soffits m2 622 Pre-painted 1200 x 600 x 9mm "Lafarge gypsum" or similar approved vinyl faced lay-in ceilings on "Xxxx" pre-painted exposed tee suspension system including main and cross tees, necessary hangers, grids, etc 7 Ceilings suspended not exceeding 1m below steel trusses and concrete soffits m2 161 Cornices, perimeter trims, etc to suspended ceilings 8 Standard 25mm aluminium "Shadow Line" or similar approved cornice m 922 Carried to Section Summary SECTION No. 2 BILL No. 9

Appears in 1 contract

Samples: www.ekurhuleni.gov.za

Descriptions. Descriptions of bolts shall be deemed to include nuts and washers Descriptions of expansion anchors and bolts and chemical anchors and bolts shall be deemed to include nuts, washers and mortices in brickwork or concrete Metalwork described as"holed for bolt(s)" shall be deemed to exclude the bolts unless otherwise described Drawings Tenderers are referred to architect's drawings annexed to this document for full details of the windows, doors, etc ALUMINIUM WINDOWS, DOORS, ETC AAAMSA guide All windows, doors, etc shall comply with and meet the minimum recommended performance requirements as set out in the General Specification for Architectural Aluminium and Glass Products (Third Edition) as published by the Association of Architectural Aluminium Manufacturers of South Africa (AAAMSA) Carried to Collection R Finish The windows, doors, etc shall be natural anodised to a thickness of 25 micron and shall comply with SABS 999 and 1407 Glass Glazing to be with patent rubber gaskets with glazing beads and comply with BS 952. Thickness of glass shall be in accordance with table 1 (Part N : Glazing ). Safety glass shall comply with SABS 1263. The National Building Regulations shall be observed with regard to the specification of safety glass Design indemnity The contractor is to submit with his tender the "Form of Indemnity", annexed to this document, fully completed and signed Drawings Tenderers are referred to architect's drawings annexed to these bills of quantities for full details of windows, doors, etc Pricing. All window prices should include alluminium louvres as shown General Workshop drawings to be approved by the architect before manufacture PRESSED STEEL DOOR FRAMES Carried to Collection R "Nty" doors 31 "Code 914" door frame size 914 x 2032mm high fitted with three (3) parliament hinges, complete with single security gate size 914 x 2032mm high overall formed of 25 x 25 x 2mm tubular section frame mitred and welded at angles and two 25 x 25 x 2mm tubular section horizontal middle rails, gate filled in with 12 x 12 x 12mm square section vertical rails at 100mm centres and fitted with locking bolt for padlock, frame formed of 25 x 38 x 2mm tubular section xxxxxx and top rail mitred and welded at angles and fitted with three hinges welded to gate and frame, frame factory welded at maximum 250mm centres to door frame No 2 PLASTERING SCREEDS Screeds on concrete 32 20mm Thick on floors m2 227 INTERNAL PLASTER Cement plaster on brickwork 33 On walls m2 164 34 On narrow widths m2 10 EXTERNAL PLASTER Cement plaster on brickwork 35 On walls TILING m2 230 SUPPLEMENTARY PREAMBLES Descriptions Unless described as "fixed with adhesive to plaster (plaster elsewhere)" descriptions of tiling Tiling on brick or concrete walls, columns, etc and floors to be fixed in stict accordance with the manufacturer's instructions and to include for adhesives, bedding and grouting complete to plastered or screeded surfaces (measured elsewhere) FLOOR TILING 300 x 300 x 11mm Xxxxxxx Ceramic floor tiles of an approved colour (code UNIJ 12523), allow the sum of R 280.00 per m2 ex factory/supplier laid on screed (elsewhere) with tile bedding and flush pointed with epoxy mortar Quantity 310.00 75,640.00 2,000.00 46,120.00 1 On floors m2 244 300 x 300 x 5mm Mosaic floor tiles of an approved colour, allow the sum of R 170.00 (one hundred and seventy rand) per m2 ex factory/supplier laid on screed (elsewhere) with tile bedding and flush pointed with epoxy mortar 250.00 280.00 8 2 On floors in showers m2 WALL TILING 200 x 200 x 6mm Xxxxxxx Glazed Ceramic White tiles (code gwc-4)fixed with adhesive to plaster (elsewhere) on brickwork or concrete and pointed with matching cement grout 3 On walls m2 323,760.00 Carried Forward to Summary of Section No. 1 SECTION 1 - BUILDING WORK TILING Rate Amount R Item No SECTION NO 1 BILL NO 8 PLUMBING AND DRAINAGE (PROVISIONAL) NOTE: For Preambles see the Model Preambles for Trades 2008 edition published by the Association of South African Quantity Surveyors SUPPLEMENTARY PREAMBLES uPVC pipes and fittings Sewer and drainage pipes and fittings shall be deemed to include 1:4 cement plaster backing jointed and descriptions of tiling on concrete floors etc sealed with butyl rubber rings Soil, waste and vent pipes and fittings shall be deemed solvent weld jointed uPVC pressure pipes and fittings Pipes for water supply shall be of the class stated Pipes of 40mm diameter and smaller shall be plain ended with solvent welded uPVC loose sockets and fittings Pipes of 50mm diameter and greater shall havesockets and spigots with push-in type integral rubber ring joints. Bends shall be uPVC and all other fittings shall be cast iron, all with similar push-in type joints Copper pipes Pipes shall be hard drawn and half-hard pipes of the class stated. Class 0 (thin walled hard drawn) pipes shall not be bent. Class 1 (thin walled half-hard), class 2 (half-hard) and class 3 (heavy walled half-hard) pipes shall only be bent with benders with inner and outer formers. Fittings to include 1:3 plaster bedding Carried to Collection R FLOOR TILING 420 x 420 11.5mm kilimanjaro floor tiles copper waste, vent and anti-syphon pipes, capillary solder fittings and compression fittings shall be "Cobra Watertech" type. Capillary solder fittings shall comply with ISO 2016. Only compression fittings shall be used in walls or similar approved by architects, fixed with adhesive, painted with tinted waterproof jointing compound. Grouting to be grey, tiles 36 On floors and landings m2 227 37 Skirting formed of cut kilimanjaro floor tile - cut to 420 x 75mm high.in ground Unit Quantity Rate

Appears in 1 contract

Samples: cjc.edu.za

AutoNDA by SimpleDocs

Descriptions. Descriptions of bolts shall be deemed to include nuts and washers Descriptions of expansion anchors and bolts and chemical anchors and bolts shall be deemed to include nuts, washers and mortices in brickwork or concrete Metalwork described as"holed for bolt(s)" shall be deemed to exclude the bolts unless otherwise described Drawings Tenderers are referred to architect's drawings annexed to this document for full details of the windows, doors, etc ALUMINIUM WINDOWS, DOORS, ETC AAAMSA guide All windows, doors, etc shall comply with and meet the minimum recommended performance requirements as set out in the General Specification for Architectural Aluminium and Glass Products (Third Edition) as published by the Association of Architectural Aluminium Manufacturers of South Africa (AAAMSA) Carried to Collection R Finish The windows, doors, etc shall be natural anodised to a thickness of 25 micron and shall comply with SABS 999 and 1407 Glass Glazing to be with patent rubber gaskets with glazing beads and comply with BS 952. Thickness of glass shall be in accordance with table 1 (Part N : Glazing ). Safety glass shall comply with SABS 1263. The National Building Regulations shall be observed with regard to the specification of safety glass Design indemnity The contractor is to submit with his tender the "Form of Indemnity", annexed to this document, fully completed and signed Drawings Tenderers are referred to architect's drawings annexed to these bills of quantities for full details of windows, doors, etc Pricing. All window prices should include alluminium louvres as shown General Workshop drawings to be approved by the architect before manufacture PRESSED STEEL DOOR FRAMES Carried to Collection R "Nty" doors 31 "Code 914" door frame size 914 x 2032mm high fitted with three (3) parliament hinges, complete with single security gate size 914 x 2032mm high overall formed of 25 x 25 x 2mm tubular section frame mitred and welded at angles and two 25 x 25 x 2mm tubular section horizontal middle rails, gate filled in with 12 x 12 x 12mm square section vertical rails at 100mm centres and fitted with locking bolt for padlock, frame formed of 25 x 38 x 2mm tubular section xxxxxx and top rail mitred and welded at angles and fitted with three hinges welded to gate and frame, frame factory welded at maximum 250mm centres to door frame No 2 PLASTERING SCREEDS Screeds on concrete 32 20mm Thick on floors m2 227 INTERNAL PLASTER Cement plaster on brickwork 33 On walls m2 164 34 On narrow widths m2 10 EXTERNAL PLASTER Cement plaster on brickwork 35 On walls TILING m2 230 SUPPLEMENTARY PREAMBLES Descriptions Unless described as "fixed with adhesive to plaster (plaster elsewhere)" descriptions of tiling Tiling on brick or concrete walls, columns, etc and floors to be fixed in stict accordance with the manufacturer's instructions and to include for adhesives, bedding and grouting complete to plastered or screeded surfaces (measured elsewhere) FLOOR TILING 300 x 300 x 11mm Xxxxxxx Ceramic floor tiles of an approved colour (code UNIJ 12523), allow the sum of R 280.00 per m2 ex factory/supplier laid on screed (elsewhere) with tile bedding and flush pointed with epoxy mortar On floors m2 208 300 x 300 x 5mm Mosaic floor tiles of an approved colour, allow the sum of R 170.00 (one hundred and seventy rand) per m2 ex factory/supplier laid on screed (elsewhere) with tile bedding and flush pointed with epoxy mortar On floors in showers m2 7 WALL TILING 200 x 200 x 6mm Xxxxxxx Glazed Ceramic White tiles (code gwc-4)fixed with adhesive to plaster (elsewhere) on brickwork or concrete and pointed with matching cement grout On walls m2 2,107 Carried Forward to Summary of Section No. 1 SECTION 1 - BUILDING WORK TILING Item No SECTION NO 1 BILL NO 8 PLUMBING AND DRAINAGE (PROVISIONAL) NOTE: For Preambles see the Model Preambles for Trades 2008 edition published by the Association of South African Quantity Surveyors SUPPLEMENTARY PREAMBLES uPVC pipes and fittings Sewer and drainage pipes and fittings shall be jointed and sealed with butyl rubber rings Soil, waste and vent pipes and fittings shall be solvent weld jointed uPVC pressure pipes and fittings Pipes for water supply shall be of the class stated Pipes of 40mm diameter and smaller shall be plain ended with solvent welded uPVC loose sockets and fittings Pipes of 50mm diameter and greater shall havesockets and spigots with push-in type integral rubber ring joints. Bends shall be uPVC and all other fittings shall be cast iron, all with similar push-in type joints Copper pipes Pipes shall be hard drawn and half-hard pipes of the class stated. Class 0 (thin walled hard drawn) pipes shall not be bent. Class 1 (thin walled half-hard), class 2 (half-hard) and class 3 (heavy walled half-hard) pipes shall only be bent with benders with inner and outer formers. Fittings to copper waste, vent and anti-syphon pipes, capillary solder fittings and compression fittings shall be "Cobra Watertech" type. Capillary solder fittings shall comply with ISO 2016. Only compression fittings shall be used in walls or in ground Unit Quantity Rate Not Priced SECTION 1 - BUILDING WORK PLUMBING AND DRAINAGE Carried to Collection R Amount Reducing fittings Where fittings have reducing ends or branches they are described as "reducing". In the case of pipes with diameters not exceeding 60mm only the largest end or branch size is given. Should the contractor wish to use other fittings and bushes or reducers he may do so on the understanding that no claim in this regard will be entertained. In the case of pipes with diameters exceeding 60mm all sizes are given and no claim for extra bushes, reducers, etc will be entertained Excavations No claim for rock excavation will be entertained unless the contractor has timeously notified the quantity surveyor thereof prior to backfilling "Soft rock" and "hard rock" shall be as defined in "Earthworks" Stainless steel basins, sinks, wash troughs, urinals, etc Units shall have standard aprons on all exposed edges and tiling keys against walls where applicable Waste unions Descriptions of waste unions shall be deemed to include 1:4 cement plaster backing rubber or vulcanite plugs and descriptions of tiling on concrete floors etc shall be deemed chains fixed to include 1:3 plaster bedding Carried to Collection R FLOOR TILING 420 x 420 11.5mm kilimanjaro floor tiles or similar approved by architects, fixed with adhesive, painted with tinted waterproof jointing compound. Grouting to be grey, tiles 36 On floors and landings m2 227 37 Skirting formed of cut kilimanjaro floor tile - cut to 420 x 75mm high.fittings SOIL DRAINAGE

Appears in 1 contract

Samples: cjc.edu.za

Time is Money Join Law Insider Premium to draft better contracts faster.