Common use of Description of Covered Items Clause in Contracts

Description of Covered Items. Mechanical parts and components of all heating systems, either hot water and steam heating system or centrally ducted forced air gas/electric/oil heating system or electric baseboard units, if providing the primary source of heat in dwelling, as follows: accessible ductwork from covered heating unit to point of attachment to register/grill; blower fan motors; burners; controls; fan blades; heat/cool thermostats; heat exchangers; heating elements; ignitor and pilot assemblies; internal system controls; wiring; and relays; motors (excludes dampers); and switches. If the primary heating system in the home is comprised of wall units, all wall units located within the home will be covered. Electric baseboard units are covered if they are the primary source of heating for the property. Examples of Items/Conditions Not Covered: Chimneys, flues, and liners; cleaning and re-lighting of pilots; concrete encased or inaccessible ductwork; concrete encased or inaccessible steam or radiant heating coils or lines; conditions of water flow restriction due to scale, rust, minerals and other deposits; fossil and dual fuel control systems and other energy management systems and controls; dampers; asbestos insulated ductwork or piping; electric baseboard heat unless primary heating system in home; filters (including electronic/electrostatic and de-ionizing filter systems); fireplaces and their respective components and gas lines; free-standing or portable heating units; fuel storage tanks, lines, and filters; gas log systems, including gas feed lines; humidifiers; inaccessible water/steam lines leading to or from system; individual space heaters; maintenance and cleaning; panels and/or cabinetry; radiant heating systems built into walls, floors or ceilings; registers and grills; secondary units; solar heating devices and components; and structural components.

Appears in 3 contracts

Samples: Home Warranty Agreement, Home Warranty Agreement, Home Warranty Agreement

AutoNDA by SimpleDocs

Description of Covered Items. Mechanical parts and components affecting the proper operation of all heating systems, either hot water and steam heating system or centrally ducted forced air gas/electric/oil heating system or electric baseboard units, if providing one (1) of each of the following appliances located in the primary source of heat kitchen: refrigerator or combination refrigerator/freezer; stand-alone freezer; built-in dwelling, as follows: accessible ductwork from covered heating unit to point of attachment to register/dishwasher; built-in grill; blower built-in microwave oven; range/oven/xxxx-top; self-contained range exhaust unit located above the range; built-in trash compactor. Kitchen appliance coverage is only for primary units. Covered mechanical parts and components include only the following: automatic soap dispenser; belts; compressor; condensers; control timers (oven/range clock-timers are excluded unless failure prohibits normal cooking function); defrost heaters; electronic components; evaporators; fan motors; burnersexposed supply lines; controlsgas valves; fan bladeshinges; heat/cool thermostats; heat exchangers; heating elementshoses; ignitor and pilot assemblies; internal system controls; wiring; latch assemblies (excluding self- cleaning latch mechanisms); motors; power cords; pulleys; pumps; ram assembly; range/cooktop/heating elements/burners (sensi-temp elements/burners will be replaced only with standard elements/burners); solid state control boards; switches and relays; motors thermostats; touch pads; tracks; transmissions; wash arm assemblies (excludes dampersdishwasher only); water filter assembly; and switcheswater valves (dishwasher only). If the primary heating system In no event shall we be liable for claims in excess of $1,500 in the home is comprised of wall unitsaggregate per Agreement term, all wall units located within the home will be covered. Electric baseboard units are covered if they are the primary source of heating for the propertyper appliance. Examples of Items/Conditions Not Covered: Chimneys, flues, Automatic deodorizers; buckets; commercial units; doors; door cables; door glass; door seals; drawers; drip pans; drums; exhaust fan not solely for venting range/cooktop fumes; faucets; filters and linersscreens; food spoilage; ice and beverage dispensers; ice makers and their respective components including water supply lines ; independent telescoping range exhaust; interior lining; internal shelves; knobs and handles; light bulbs and fixtures; lock and key assemblies; panels and/or cabinetry; racks; removable minitubs; rollers; rooftop exhaust units; rotisseries and probes; secondary units; self-cleaning mechanisms including door latches; sensi-temp/sensi-heat burners; shelves; springs; stoppages and re-lighting of pilotsconditions causing or caused by stoppages; concrete encased or inaccessible ductworkstructural components; concrete encased or inaccessible steam or radiant heating coils or linestimers and clocks; trays; tubs; venting; conditions of water flow restriction due to scale, rust, minerals and other deposits; fossil and dual fuel control systems and other energy management systems and controls; dampers; asbestos insulated ductwork or piping; electric baseboard heat unless primary heating system in home; filters (including electronic/electrostatic and de-ionizing filter systems); fireplaces and their respective components and gas lines; free-standing or portable heating units; fuel storage tanks, lines, and filters; gas log systems, including gas feed lines; humidifiers; inaccessible water/steam lines leading to or from system; individual space heaters; maintenance and cleaning; panels and/or cabinetry; radiant heating systems built into walls, floors or ceilings; registers and grills; secondary units; solar heating devices and components; and structural components.

Appears in 1 contract

Samples: Totalprotect Kitchen Warranty Agreement

Description of Covered Items. Mechanical parts and components of all heating systemsone (1) system, either hot water and steam heating system or centrally ducted forced air air/gas/electric/oil electric heating system or electric baseboard units, if providing the primary source of heat in dwelling, as follows: accessible ductwork from covered heating unit to point of attachment to register/grill; blower fan motors; burners; controls; fan blades; heat/cool thermostatsthermostats (electronic set back units will be replaced only with standard units); heat exchangers; heating elements; ignitor and pilot assemblies; internal system controls; , wiring; , and relays; motors (excludes dampers); and switches. If the primary heating system in the home is comprised of wall units, all wall units located within the home will be covered. Electric baseboard units are covered if they are the primary source of heating for the property. In no event shall we be liable for claims in excess of $1,500 in the aggregate per Agreement term, per covered property for systems that have been converted from coal-to-oil, coal-to-gas, or oil-to-gas; or for hot water or steam heating systems including radiators, vent pipes/lines, or oil fired forced air systems. Examples of Items/Conditions Not Covered: Chimneys, flues, and liners; cleaning and re-lighting of pilotsburners; concrete encased or inaccessible ductwork; concrete encased or inaccessible steam or radiant heating coils or lines; conditions of water flow restriction due to scale, rust, minerals and other deposits; fossil and dual fuel control systems and other energy management systems and controls; dampers; asbestos insulated ductwork or piping; electric baseboard heat unless primary heating system in home; filters (including electronic/electrostatic and de-ionizing filter systems); fireplaces and their respective components and gas lines; free-standing or portable heating units; fuel storage tanks, lines, and filters; gas log systems, including gas feed lines; humidifiers; inaccessible water/steam lines leading to or from system; individual space heaters; maintenance and cleaning; panels and/or cabinetry; pressure regulators; radiant heating systems built into walls, floors or ceilings; registers and grills; secondary units; solar heating devices and components; and structural components.

Appears in 1 contract

Samples: Totalprotect Home Service Agreement

AutoNDA by SimpleDocs

Description of Covered Items. Mechanical parts and components of all heating systemsone (1) system, either hot water and steam heating system or centrally ducted forced air air/gas/electric/oil electric heating system or electric baseboard units, if providing the primary source of heat in dwelling, as follows: accessible ductwork from covered heating unit to point of attachment to register/grill; blower fan motors; burners; controls; fan blades; heat/cool thermostatsthermostats (electronic set back units will be replaced only with standard units); heat exchangers; heating elements; ignitor and pilot assemblies; internal system controls; , wiring; , and relays; motors (excludes dampers); and switches. If the primary heating system in the home is comprised of wall units, all wall units located within the home will be covered. Electric baseboard units are covered if they are the primary source of heating for the property. In no event shall we be liable for claims in excess of $1,500 in the aggregate per Agreement term, per covered property for systems that have been converted from coal-to-oil, coal-to-gas, or oil-togas; or for hot water or steam heating systems including radiators, vent pipes/lines, or oil fired forced air systems. Examples of Items/Conditions Not Covered: Chimneys, flues, and liners; cleaning and re-lighting of pilotsburners; concrete encased or inaccessible ductwork; concrete encased or inaccessible steam or radiant heating coils or lines; conditions of water flow restriction due to scale, rust, minerals and other deposits; fossil and dual fuel control systems and other energy management systems and controls; dampers; asbestos insulated ductwork or piping; electric baseboard heat unless primary heating system in home; filters (including electronic/electrostatic and de-ionizing filter systems); fireplaces and their respective components and gas lines; free-free- standing or portable heating units; fuel storage tanks, lines, and filters; gas log systems, including gas feed lines; humidifiers; inaccessible water/steam lines leading to or from system; individual space heaters; maintenance and cleaning; panels and/or cabinetry; pressure regulators; radiant heating systems built into walls, floors or ceilings; registers and grills; secondary units; solar heating devices and components; and structural components.

Appears in 1 contract

Samples: Totalprotect Systems Warranty Agreement

Time is Money Join Law Insider Premium to draft better contracts faster.