Common use of CARPENTRY Clause in Contracts

CARPENTRY. As per exhibit D-1, Landlord shall reuse existing partitions where applicable. · Landlord shall provide drywall partitions with 2-1/2” metal studs at 24” on center, non insulated, with one (1) layer of 5/8” gypsum board, both sides. Partition to extend 6” above finished ceiling. Landlord shall provide partitions as per exhibit D-1. · Landlord shall provide Demising Partitions where required with 2-1/2” metal studs at 24” on center, insulated, with one (1) layer of 5/8” gypsum board, both sides. Partition to be fire rated as per code. Where applicable, Landlord shall upgrade existing partitions to be fire rated as per code. · Landlord shall provide one (1) 4’-0”x8’-0” fire rated plywood panel for tel/data use.