Common use of Wall Systems Clause in Contracts

Wall Systems. All interior walls, except restrooms, shall be painted or field applied vinyl covered 5/8" gypsum board. Vinyl fabric shall be medium weight, textured, wall covering with stain resistant surface coatings. 4" vinyl base shall be applied to all walls. Metal studs, floor and ceiling track shall be 20 gauge galvanized steel spaced at 16" o.c. (24" o.c. not acceptable). Gypsum board fasteners shall be drywall screws not less than 1¼” long. Painted surfaces shall receive 1 coat of primer and 2 coats of finish. A complete room finish schedule shall be submitted for approval by the Lessee prior to construction. Colors shall be selected by the Lessee. Provide clear plastic guards up to 48” a.f.f. on all interior outside corners to protect vinyl wall covering. Exterior wall insulation is to be covered from floor to roof deck with ½" gypsum board. Gypsum board above the acoustic ceiling line may be unfinished. Walls in restrooms shall be finished with glazed wall tile extending from floor to 60" a.f.f. Tile shall be standard grade meeting ANSI 137.1.

Appears in 2 contracts

Sources: Lease Agreement, Lease Agreement

Wall Systems. All interior walls, except restrooms, shall be painted or field applied vinyl covered 5/8" gypsum board. Vinyl fabric shall be medium weight, textured, wall covering with stain resistant surface coatings. 4" vinyl base shall be applied to all walls. Metal studs, floor and ceiling track shall be 20 gauge galvanized steel spaced at 16" o.c. (24" o.c. not acceptable). Gypsum board fasteners shall be drywall screws not less than 1¼” long. Painted surfaces shall receive 1 coat of primer and 2 coats of finish. A complete room finish schedule shall be submitted for approval by the Lessee prior to construction. Colors shall be selected by the Lessee. Provide clear plastic guards up to 48” a.f.f. on all interior outside corners to protect vinyl wall covering. Gypsum drywall partitioning allowance: provide 1 lineal foot of gypsum drywall partition (finished on each side) for each 25 square feet of space rented referenced in Article I of the Lease. Exterior wall insulation is to be covered from floor to roof deck with ½" gypsum board. Gypsum board above the acoustic ceiling line may be unfinished. 1. Walls in restrooms separating the garage storage compartments shall be finished with glazed wall tile extending from floor concrete block to 6096" a.f.f. Tile shall be standard grade meeting ANSI 137.1., with metal studs and drywall above.

Appears in 1 contract

Sources: Lease Agreement