Verification Testing Sample Clauses

Verification Testing a. Upon initial parallel operation of the Facility, or any time interface hardware or software is changed, a verification test of Seller-Owned Interconnection Facilities shall be performed by Seller. A qualified individual, hired or employed by the Seller, shall perform the verification testing in accordance with the manufacturer’s published test procedure. Qualified individuals include professional engineers, factory trained and certified technicians, and licensed electricians with experience in testing protective equipment.
AutoNDA by SimpleDocs
Verification Testing. UL Contracting Party will perform periodic retesting of Client’s products it has assessed and found to comply with the energy efficiency requirements as previously outlined in the Quotation to verify their ongoing compliance. On an annual basis, the review may include UL Contracting Party’s retesting of at least 5%, or as specified in the Program specific requirements, of Client’s models representing Client’s product(s) previously found to comply with the energy efficiency requirements by procuring those such products from customary retail distribution channels, or as specified in the Program specific requirements. The acquisition and testing of such samples will be at Client’s expense. UL Contracting Party reserves the right to revoke use of the UL Mark on products and remove listing from the UL Contracting Party’s Product Database if UL Contracting Party determines the product is not in compliance with the requirements as outlined on the Quotation covering the UL Contracting Party’s Service preformed. If Client makes changes to the product(s) that will take the product(s) out of compliance with the requirements outlined on the Quotation, Client must promptly notify UL Contracting Party and submit the product for a re-assessment. If changes are made that take the product out of compliance and UL Contracting Party is not notified, Client may be required to suspend use of the UL Mark, report and/or certificate and pay a penalty when these changes are discovered during the annual verification testing. Continued noncompliance of the product may result in complete withdrawal from the EEC Services program.
Verification Testing a. Upon initial parallel operation of the Generating Facility, or any time interface hardware or software is changed, a verification test shall be performed. A licensed professional engineer or otherwise qualified individual shall perform verification testing in accordance with the manufacturer’s published test procedure. Qualified individuals include professional engineers, factory trained and certified technicians, and licensed electricians with experience in testing protective equipment. The Company reserves the right to witness verification testing or require written certification that the testing was performed.
Verification Testing. Licensee must verify each Licensed Hard Core Implementation developed by Licensee pursuant to the license described in Section 2.1 or 2.3 of the Master Agreement on each process to be used for volume manufacture. For each such Licensed Hard Core Implementation developed pursuant to the rights granted in Section 2.1, Licensee shall run the latest architecture verification program (“AVP” or “Architecture Verification Program”) provided by MIPS under the applicable Technology Schedule, without any modification to the AVP, in accordance with the process set forth in either Section 2 or in Section 3 of this Exhibit B. For each such Licensed Hard Core Implementation developed pursuant to the rights granted in Section 2.3, Licensee shall run the latest verification test suite (“VTS” or “Verification Test Suite”) provided by MIPS under the applicable Technology Schedule, without any modification to the VTS, in accordance with the process set forth in either Section 2 or in Section 3 of this Exhibit B.
Verification Testing. For all Products or its parts specification, Manufacturer shall draft appropriate verification protocol and perform the testing in accordance with that protocol. IWT shall author the system verification protocol and IWT shall accomplish verification and validation of the Product (“Verification Testing”). Third party (independent qualified testing facility) testing, in addition to related test materials, as shall be approved in advance by IWT, shall be paid by IWT, and shall be an agent of IWT. Test materials shall be the exclusive property of IWT. IWT will collect and/or prepare for Manufacturer data including vibration, shock, temperature, etc. of the actual environment where the product will be used. IWT will also perform operation verification during and at the end of development, operation verification on the actual test drive (field test), life and durability test, and the final acceptance tests.
Verification Testing. The Grantor shall perform a verification test on the Products and Other Products manufactured in accordance with the Technology. If the verification test indicates that the manufacture of the Products or Other Products is in conformity with the technical specifications of the Technology, the verification test shall be considered to have been successfully completed. In the event that the verification is not successfully completed, the Grantor shall analyze the causes and take the necessary measures to eliminate the defects.
Verification Testing. 3.3.2.3.1 The Contractor shall support verification and validation testing of new systems and modifications to existing systems IAW plans and procedures including, but not limited to, factory acceptance testing, equipment receipt, system and modification integration, system and modification installation, System Operations Verification Testing (SOVT), and customer acceptance.
AutoNDA by SimpleDocs
Verification Testing. Consultant shall oversee all testing of component materials and completed work items to the extent that it assures that the materials and workmanship incorporated in the Project are in conformity with the plans, specifications, and construction contract provisions.
Verification Testing a. Upon initial parallel operation of the Generating Facility, or any time either (i) interface hardware or software is changed, or (ii) the Company observes that the Subscriber Organization is not in compliance with the operational and performance requirements specified in the Company’s Rule 14H, this Agreement and/or the SFC, a verification test shall be performed. Such verification test shall include testing of the telemetry and control interface which allows the Company to remotely measure, monitor, evaluate and verify technical compliance. Generating Facility performance, and power quality and, if necessary, control the Generating Facility. A licensed professional engineer or otherwise qualified individual shall perform verification testing in accordance with the manufacturer’s published test procedure. Qualified individuals include professional engineers, factory trained and certified technicians, and licensed electricians with experience in testing protective equipment. The Company reserves the right to witness verification testing or require written certification that the testing was performed.

Related to Verification Testing

  • Inspection/Testing All Products sold pursuant to this Agreement will be subject to inspection/testing by or at the direction of H- GAC and/or the ordering Customer, either at the delivery destination or the place of manufacture. In the event a Product fails to meet or exceed all requirements of this Agreement, and unless otherwise agreed in advance, the cost of any inspection and/or testing, will be the responsibility of the Contractor.

  • ODUF Testing 6.6.1 Upon request from TWTC, AT&T shall send ODUF test files to TWTC. The Parties agree to review and discuss the ODUF file content and/or format. For testing of usage results, AT&T shall request that TWTC set up a production (live) file. The live test may consist of TWTC’s employees making test calls for the types of services TWTC requests on ODUF. These test calls are logged by TWTC, and the logs are provided to AT&T. These logs will be used to verify the files. Testing will be completed within thirty (30) days from the date on which the initial test file was sent.

  • Random Testing Notwithstanding any provisions of the Collective Agreement or any special agreements appended thereto, section 4.6 of the Canadian Model will not be applied by agreement. If applied to a worker dispatched by the Union, it will be applied or deemed to be applied unilaterally by the Employer. The Union retains the right to grieve the legality of any imposition of random testing in accordance with the Grievance Procedure set out in this Collective Agreement.

  • E-Verification If applicable, Contractor represents and warrants that it will ensure its compliance with the Mississippi Employment Protection Act of 2008, and will register and participate in the status verification system for all newly hired employees. Mississippi Code Annotated §§ 71-11-1 et seq. The term “employee” as used herein means any person that is hired to perform work within the State of Mississippi. As used herein, “status verification system” means the Illegal Immigration Reform and Immigration Responsibility Act of 1996 that is operated by the United States Department of Homeland Security, also known as the E-Verify Program, or any other successor electronic verification system replacing the E-Verify Program. Contractor agrees to maintain records of such compliance. Upon request of the State and after approval of the Social Security Administration or Department of Homeland Security when required, Contractor agrees to provide a copy of each such verification. Contractor further represents and warrants that any person assigned to perform services hereafter meets the employment eligibility requirements of all immigration laws. The breach of this agreement may subject Contractor to the following:

  • Test The outer surface of the lamp lenses shall be subjected once or more than once to the action of the sand jet produced as described above. The jet shall be sprayed almost perpendicular to the surface to be tested. The deterioration shall be checked by means of one or more samples of glass placed as a reference near the lenses to be tested. The mixture shall be sprayed until the variation in the diffusion of light on the sample or samples measured by the method described in Appendix 2, is such that: Δ d = (T5 - T4) / T2 ≤ 0.0250 ± 0.0025 Several reference samples may be used to check that the whole surface to be tested has deteriorated homogeneously. Annex 6 - Appendix 4

  • MEASUREMENT AND VERIFICATION The goal of this task is to report the benefits resulting from this project. Project team may use in- house expertise of the project demonstration site or use third party vendor for measurement and verification (M&V) of GHG and energy consumption reduction. The Recipient shall: • Enter into agreement with M&V subcontractor per Task 1.9 • Coordinate site visits with the M&V subcontractor at the demonstration sites • Develop M&V protocol for pre-installation measurement (and calculation): o Electric, natural gas and/or other fossil fuel consumption and GHG emissions (use appropriate emissions factor from Attachment 8 of the grant solicitation) of the equipment/process/system(s)/sub-system(s) that are to be upgraded and/or replaced and/or modified. o Ensure installation of sub-metering equipment and data loggers for pre/post data analysis. • Prepare and provide a detailed M&V Plan for each project demonstration site to include but not be limited to: o Description of the monitoring equipment and instrumentation which will be used. o Description of the key input parameters and output metrics which will be measured. o Description of the M&V protocol and analysis methods to be employed. o Description of the independent, third-party M&V services to be employed, if applicable. • Perform three months (or shorter period as approved in writing by the CAM) of pre- installation measurements (and calculations) based on the M&V protocol for pre- installation. • Prepare and provide a Pre-Installation M&V Findings Report for each demonstration site that includes M&V protocol, pre-install measurements (and calculations), analysis, and results performed in this task. • Develop M&V protocol for post-installation measurements (and calculations) of: o Electric, natural gas and/or other fossil fuel consumption and GHG emissions (use appropriate emissions factor from Attachment 8 of the grant solicitation) of the equipment/process/system(s)/sub-system(s) that will be upgraded and/or replaced and/or modified  Perform 12 months or two seasons, for seasonal facilities, (or shorter period as approved in writing by the CAM) of post-installation measurements based on M&V protocol for post-installation. • Provide a summary of post-installation M&V progress in Progress Report(s) (see subtask 1.5) which shall include but not be limited to: o A narrative on operational highlights from the reporting period, including any stoppages in operation and why; and o A summary of M&V findings from the reporting period. • Analyze post-installation electrical, natural gas and/or other fossil fuel consumption and GHG emissions. • Prepare and provide a Post-Installation M&V Findings Report for each demonstration site that includes M&V protocol, pre and post install measurements (and calculations), analysis, and results performed in this task. Results should at a minimum report on the reduction of electricity, natural gas and/or other fossil fuel usage and reductions of GHG emissions that directly result from this project and include the following: o Provide all key assumptions used to estimate and determine energy and GHG reductions (and additions, if applicable). o Provide all key assumptions used to estimate projected benefits, including targeted market sector (e.g., population and geographic location), projected market penetration, baseline and projected energy use and cost, operating conditions, and emission reduction calculations. o Discuss whether the energy and GHG emission reductions identified in section II.C were met. • Prepare a CPR Report #2 in accordance with subtask 1.3. • Participate in a CPR Meeting #2.

  • Verification Bank may, from time to time, verify directly with the respective Account Debtors the validity, amount and other matters relating to the Accounts, either in the name of Borrower or Bank or such other name as Bank may choose.

  • Testing Landlord shall have the right to conduct annual tests of the Premises to determine whether any contamination of the Premises or the Project has occurred as a result of Tenant’s use. Tenant shall be required to pay the cost of such annual test of the Premises; provided, however, that if Tenant conducts its own tests of the Premises using third party contractors and test procedures acceptable to Landlord which tests are certified to Landlord, Landlord shall accept such tests in lieu of the annual tests to be paid for by Tenant. In addition, at any time, and from time to time, prior to the expiration or earlier termination of the Term, Landlord shall have the right to conduct appropriate tests of the Premises and the Project to determine if contamination has occurred as a result of Tenant’s use of the Premises. In connection with such testing, upon the request of Landlord, Tenant shall deliver to Landlord or its consultant such non-proprietary information concerning the use of Hazardous Materials in or about the Premises by Tenant or any Tenant Party. If contamination has occurred for which Tenant is liable under this Section 30, Tenant shall pay all costs to conduct such tests. If no such contamination is found, Landlord shall pay the costs of such tests (which shall not constitute an Operating Expense). Landlord shall provide Tenant with a copy of all third party, non-confidential reports and tests of the Premises made by or on behalf of Landlord during the Term without representation or warranty and subject to a confidentiality agreement. Tenant shall, at its sole cost and expense, promptly and satisfactorily remediate any environmental conditions identified by such testing in accordance with all Environmental Requirements. Landlord’s receipt of or satisfaction with any environmental assessment in no way waives any rights which Landlord may have against Tenant.

  • Compliance Verification (a) The subrecipient shall periodically interview a sufficient number of employees entitled to DB prevailing wages (covered employees) to verify that contractors or subcontractors are paying the appropriate wage rates. As provided in 29 CFR 5.6(a)(6), all interviews must be conducted in confidence. The subrecipient must use Standard Form 1445 (SF 1445) or equivalent documentation to memorialize the interviews. Copies of the SF 1445 are available from EPA on request.

  • Drug Testing (A) The state and the PBA agree to drug testing of employees in accordance with section 112.0455, F.S., the Drug-Free Workplace Act.

Time is Money Join Law Insider Premium to draft better contracts faster.