Unused Log Receipt Tickets Sample Clauses

Unused Log Receipt Tickets. Prior to release of bond, unused log load receipt tickets will be returned to the COUNTY. Missing or unaccounted for tickets will be bought by the PURCHASER for double the average scaled truckload multiplied by the purchase price per thousand for Xxxxxxx-fir #4 sawmill and better.
AutoNDA by SimpleDocs

Related to Unused Log Receipt Tickets

  • Gross Receipts The entire amount of all receipts, determined on a cash basis, from (a) tenant rentals collected pursuant to tenant leases of apartment units, for each month during the term hereof; provided that there shall be excluded from tenant rentals any tenant security deposits (except as provided below); (b) cleaning, tenant security and damage deposits forfeited by tenants in such period; (c) laundry and vending machines income; (d) any and all other receipts from the operation of the Project received and relating to the period in question; (e) proceeds from rental interruption insurance, but not any other insurance proceeds or proceeds from third-party damage claims, and (f) any other sums and charges collected in connection with termination of the tenant leases. Gross Receipts do not include the proceeds of (i) any sale, exchange, refinancing, condemnation, or other disposition of all or any part of the Project, (ii) any loans to Owner whether or not secured by all or any part of the Project, (iii) any capital expenditures or funds deposited to cover costs of operations made by Owner, and (iv) any insurance policy (other than rental interruption insurance or proceeds from third-party damage claims).

  • Gross Revenue 16.1.1 For the purposes of this PPP Agreement and its Schedules, Gross Revenue shall be defined as:

  • Monthly Data Download Not later than fifteen (15) days after the end of each month, beginning with the month in which the Commencement Date occurs and ending with the Final Shared-Loss Month, Assuming Institution shall provide Receiver:

  • Load Receipts PURCHASER shall completely and accurately fill out all portions of a multipart, serially numbered log load receipt before each truck leaves the landing area. PURCHASER shall require the truck driver of each load of logs to sign the xxxxx receipt. PURCHASER shall staple the load receipt and scaler receipt parts to the load as instructed on the log load receipt directions and as directed by STATE, before each truck leaves the landing area. PURCHASER shall require the scaler to record the log load receipt number on the scale ticket that is signed by the scaler, and to attach the scaler receipt part to a copy of the scale ticket and mail to STATE on the date scaled. STATE shall issue to PURCHASER sufficient books of serially numbered log load receipts to cover up to 30 days of operation, as determined by STATE. PURCHASER shall sign a receipt for each book of receipts and be fully accountable for all serially numbered xxxxx and scaler receipt tickets. PURCHASER shall retain all xxxxx receipts in each book and return to STATE as soon as all receipts in each book have been used. Unused books or portions of books shall be returned to STATE during sale inactivity over 30 days, and at the completion of timber removal from the timber sale area. PURCHASER shall account for each and every serially numbered log load receipt, and shall pay damages to STATE for all log load receipts not accounted for by proof of scaling. Damages shall consist of full stumpage rate for each missing receipt, on the basis of average volume of the 10 largest loads of logs scaled from the timber sale area, charged at the highest species rate. PURCHASER shall not intermingle STATE timber or logs designated by this contract with any other timber or logs before log scaling occurs, unless otherwise approved by STATE.

  • CAISO Monthly Billed Fuel Cost [for Geysers Main only] The CAISO Monthly Billed Fuel Cost is given by Equation C2-1. CAISO Monthly Billed Fuel Cost Equation C2-1 = Billable MWh ◆ Steam Price ($/MWh) Where: • Steam Price is $16.34/MWh. • For purposes of Equation C2-1, Billable MWh is all Billable MWh Delivered after cumulative Hourly Metered Total Net Generation during the Contract Year from all Units exceeds the Minimum Annual Generation given by Equation C2-2. Equation C2-2 Minimum Annual Generation = (Annual Average Field Capacity ◆ 8760 hours ◆ 0.4) - (A+B+C) Where: • Annual Average Field Capacity is the arithmetic average of the two Field Capacities in MW for each Contract Year, determined as described below. Field Capacity shall be determined for each six-month period from July 1 through December 31 of the preceding calendar year and January 1 through June 30 of the Contract Year. Field Capacity shall be the average of the five highest amounts of net generation (in MWh) simultaneously achieved by all Units during eight-hour periods within the six-month period. The capacity simultaneously achieved by all Units during each eight-hour period shall be the sum of Hourly Metered Total Net Generation for all Units during such eight-hour period, divided by eight hours. Such eight-hour periods shall not overlap or be counted more than once but may be consecutive. Within 30 days after the end of each six-month period, Owner shall provide CAISO and the Responsible Utility with its determination of Field Capacity, including all information necessary to validate that determination. • A is the amount of Energy that cannot be produced (as defined below) due to the curtailment of a Unit during a test of the Facility, a Unit or the steam field agreed to by CAISO and Owner. • B is the amount of Energy that cannot be produced (as defined below) due to the retirement of a Unit or due to a Unit’s Availability remaining at zero after a period of ten Months during which the Unit’s Availability has been zero. • C is the amount of Energy that cannot be produced (as defined below) because a Force Majeure Event reduces a Unit’s Availability to zero for at least thirty (30) days or because a Force Majeure Event reduces a Unit’s Availability for at least one hundred eighty (180) days to a level below the Unit Availability Limit immediately prior to the Force Majeure Event. • The amount of Energy that cannot be produced is the sum, for each Settlement Period during which the condition applicable to A, B or C above exists, of the difference between the Unit Availability Limit immediately prior to the condition and the Unit Availability Limit during the condition.

  • Terminal Receipt You can get a receipt at the time you make any transaction (except inquiries) involving your account using an ATM and/or point-of-sale (POS) terminal.

  • Billing Period The calendar month shall be the standard period for all charges and payments under this Agreement. On or before the fifteenth (15th) day following the end of each month, Seller shall render to Buyer an invoice for the payment obligations incurred hereunder during the preceding month, based on the Energy Delivered in the preceding month, and any RECs deposited in Buyer’s GIS account or a GIS account designated by Buyer to Seller in writing in the preceding month. Such invoice shall contain supporting detail for all charges reflected on the invoice, and Seller shall provide Buyer with additional supporting documentation and information as Buyer may request.

  • Contract Quarterly Sales Reports The Contractor shall submit complete Quarterly Sales Reports to the Department’s Contract Manager within 30 calendar days after the close of each State fiscal quarter (the State’s fiscal quarters close on September 30, December 31, March 31, and June 30). Reports must be submitted in MS Excel using the DMS Quarterly Sales Report Format, which can be accessed at xxxxx://xxx.xxx.xxxxxxxxx.xxx/business_operations/ state_purchasing/vendor_resources/quarterly_sales_report_format. Initiation and submission of the most recent version of the Quarterly Sales Report posted on the DMS website is the responsibility of the Contractor without prompting or notification from the Department’s Contract Manager. If no orders are received during the quarter, the Contractor must email the DMS Contract Manager confirming there was no activity.

  • Xxxxx Period After payment of the first Dues, the Subscriber is entitled to a grace period of 30 days for the pay- ment of any Dues due. During this grace period, the Agreement will remain in force. However, the Sub- xxxxxxx will be liable for payment of Dues accruing during the period the Agreement continues in force.

  • Monthly Billing The electric service charge shall be computed in accordance with the monthly billing in the applicable standard service tariff. Customers receiving electric service under residential and small nonresidential schedules 1, 2, 3, 15, 23 or 23B shall be financially credited for such net energy with a cumulative kilowatt-hour credit. The credit will be deducted from the customer’s kilowatt-hour usage on the customer’s next monthly bill thus offsetting the customer’s next monthly bill at the full retail rate of the customer’s rate schedule. Customers receiving electric service under large nonresidential schedules 6, 6A, 6B, 8 or 10 must elect a compensation method to receive cumulative credits for the upcoming annualized billing period from one of the following options (large nonresidential customers must initial desired credit election): an average energy price, a seasonally differentiated energy price, or an average retail rate.

Time is Money Join Law Insider Premium to draft better contracts faster.