Test Reports Sample Clauses

Test Reports. Within five (5) business days after the completion of the performance test, Seller shall prepare and submit to Department a written report of the test in accordance with Section 6 of PTC 22. At a minimum, the report shall include (i) the approved test procedure, (ii) a record of the personnel present for the test whether serving in an operating, testing, monitoring or other such participatory role, (iii) documentation of the satisfactory completion of the start-up and stabilization period, (iv) a record of any unusual or abnormal conditions or events that occurred during the test and any actions taken in response thereto, (v) the measured data, (vi) a verification of the validity of the test in accordance with Section 3.5.1 of PTC 22, (vii) the adjusted data with supporting calculations, (viii) Plant Capacity with supporting calculations, (ix) a curve showing MW output versus ambient temperature over the range of 40 F to 120 F with and without inlet cooling in service, and the curve with inlet cooling in service shall be used for Dispatch purposes, and (x) Seller’s statement of either Seller’s acceptance of the test or Seller’s rejection of the test and reason(s) therefore. Within five (5) business days after receipt of such report, Department shall notify Seller in writing of either Department’s acceptance of the test or Department’s rejection of the test and reason(s) therefore
Test Reports. (a) Seller shall deliver to Buyer a preliminary test report, including the test data sheets and calculated results for each Performance Test or retest (the “Preliminary Performance Test Report”), promptly after completion of each Performance Test, together with a notice to Buyer certifying completion of the Performance Tests in accordance with this Agreement and results of such Performance Tests. Promptly after receipt of such Preliminary Performance Test Report, Buyer and Seller shall consult concerning the results of such tests, and within three (3) days thereafter, Buyer shall (i) state it concurs with the results of the Performance Tests or (ii) state it disputes the results of the Performance Tests and stating in detail the reasons therefor. Within fifteen (15) Business Days following completion of the Performance Tests, Seller shall provide to Buyer a final test report, including test data sheets and calculated results of each Performance Test or retest (the “Final Performance Test Report”) and a final notice to Buyer certifying completion of the Performance Tests. Within fifteen (15) days of receipt of such documentation from Seller, Buyer shall either (i) accept the Performance Test results or (ii) state it disputes the results of the Performance Tests and the reasons therefor. If Buyer disputes the accuracy of the Performance Tests results in the Final Performance Test Report, then Seller shall re-perform the applicable Performance Tests (or part thereof) in accordance with the procedures set forth in Appendix H. If the results of the re-test confirm the accuracy of the initial test, then Buyer shall pay the increased costs directly resulting from the re- test. If the results of the re-test do not confirm the accuracy of the initial test, then Seller shall pay for the costs of the re-test and any subsequent tests necessary to confirm compliance with all Performance Guarantees.
Test Reports. The Contractor shall deliver a test report at the conclusion of each formal test activity. These reports are described in paragraph 3.5.2.
Test Reports. NDD shall test or cause to be tested each batch of ASICs pursuant to this Agreement before delivery to CMS. Each test shall set forth the items tested, specifications and test results in a report for each batch delivered. NDD shall send or cause to be sent such report to CMS along with delivery of the ASICs. CMS is entitled to rely on such report for all purposes of this Agreement. Nothing in this Agreement shall be construed to require CMS to perform any incoming testing, analytical or otherwise, on any ASICs received from NDD.
Test Reports a. ......................................................
Test Reports. Unless otherwise agreed between the parties, if the SRAS Provider conducts a Test, the SRAS Provider must provide a test report to AEMO that complies with the requirements for test reports set out in the SRAS Guideline, within 15 business days of the Test being conducted.
Test Reports. The Contractor shall prepare test reports documenting the results of the test activity, including procedures executed, procedure pass/fail status, discrepancies discovered, and data collected. Discrepancies that cause system degradation or indicate a failure to meet performance specifications shall be discussed with system impact defined and correction plans indicated.
Test Reports. Supplier shall submit certified test reports for all specified tests.
Test Reports. Contractor shall produce all necessary component, subsystem, and instrument level test reports. Each report shall include detailed descriptions of test observations and discrepancies as well as quantitative verification of test objectives. Test reports will be available for DigitalGlobe review after the test. Test reports used for requirements verification shall be provided to DigitalGlobe. DigitalGlobe Proprietary and Confidential Use or disclosure of data is subject to the restriction on the title page of this document.