Site Development Requirements Clause Samples

The Site Development Requirements clause sets out the standards and obligations that must be met during the development or improvement of a property or project site. It typically details specifications such as permitted construction methods, environmental protections, safety measures, and compliance with local regulations. By clearly outlining these requirements, the clause ensures that all parties understand their responsibilities, reducing the risk of disputes and helping to maintain project quality and legal compliance.
Site Development Requirements. The dimensional requirements within the Project will be as set forth in the table at Section 5.2 .
Site Development Requirements. Formatted: Justified (a) The following table lists the site development requirements that are applicable within each TractPlanning Area of the Project. Minor deviations up to (10%) percent of the site development requirements may be granted administratively by the City through the City Manager. Other deviations shall be processed as variances in accordance with the LDC. A Comparative Zoning Analysis PlanTable of Residential Site Development Requirements which evaluates provides the PUDMPD development criteria and the City of Palm Coast zoning criteriafor the residential Planning Areas is attached hereto as Exhibit 7Table 55.2. Overall project Overall project Overall Overall Maximum Dwelling Exhibit Table 5.27 Table of Residential Site Development Requirements 50 FT 70 FT 20 SFFT(8) N/AN/A20 FT Minimum Lot Width 5,000 SF 6,600 SF N/A1,500 SFN/A Minimum Lot Size TractPlanning Area 3 (SFR-3) TractPlanning Area 2 (SFR-2) Fee Simple Townhome Multi- Family TractPlanning Area 1113 TractPlannin g Area 4 5 & 6 Units Per Acre project density = 2.6 DU/AC project density = 2.6 DU/AC project density = 2.6 DU/AC density = 2.6 DU/AC density = 2.6 DU/AC Minimum Living Area 1,275 SF 1,200 SF 1,200 SF 2,200 SF 1,800 SF Minimum Front Setback 50 FT(5) 20 FT(2) 20 FT(2) 20 FT 20 FT Minimum Rear Setback 20 FT(1) N/A10 FT(6) 10 SFFT 20 FT(1) 10 FT(1) Minimum Rear Street Setback N/A 20 FT(1) (2) 20 FT(1) (2) 20 FT(1) 20 FT(1) Minimum Side Interior Setback N/A N/A 10 SFFT(7) 7.5 FT(1) 5 FT(1) Minimum Side Street Setback 50 FT(1) (5) 20 2010 FT(1) (2) 120 SFFT(8) 20 FT(1) 20 FT(1) Maximum Impervious Surface Ratio (ISR) Overall project maximum impervious area = 0.70% Overall project maximum impervious area = 0.70% Overall project maximum impervious area = 0.70% Overall project maximum impervious area = 0.70% Overall project maximum impervious area = 0.70% Minimum Distance ▇▇▇▇▇▇▇ ▇▇▇▇▇▇▇▇▇ ▇▇ FT 20 FT 20 FT N/A N/A Maximum Building Height 60 FT 35 FT 35 FT 35 FT 35 FT Minimum Parking 2 SP/DU(3) 2 SP/DU(4 ) 2 SP/DU(4 ) 2 SP/DU 2 SP/DU (1) Exterior air conditioning units and related heating/cooling units may encroach upon the setback. (2) Setback measured from roadway/parking lot edge of pavement. (3) Parking for 1/3rd of the multi-family TractPlanning Area 4 5 units will be within garages. The garage parking spaces will have contiguous exterior parking spaces. Each garage space and contiguous exterior space will be counted as separate parking spaces. Refer to Multi-family (TractPlann...
Site Development Requirements. Development of the property shall generally be governed by the master site development plan and as such, shall precede the platting process. (a) Minimum Lot Size/Width – Minimum lot size is 5,000 square feet and the minimum width is sixty (60 feet). Lot width is measured along the front setback line from the front lot line. The front lot line is the line that abuts the right-of-way. The interior lot (hotel site), as depicted, is excepted from the front lot line setback requirement. (b) Impervious Surface Ratio (ISR)/Floor Area Ratio (FAR) - The maximum impervious surface ratio (ISR) is 0.70. The maximum floor area ratio (FAR) is 40. The FAR for the development of the Subject Property shall be calculated based on the ratio of all developed buildings to the total area of the Subject Property rather than the area of individual lots. A portion of the off-site detention area can be credited to the Subject Property for purposes of calculating the ISR and FAR as outlined in section 03.05.03 of the LDC. Any one site may exceed the ISR, but the overall ISR for the development of the Subject Property upon completion shall be 0.70. In all cases, the Development shall function as one cohesive development with all occupants having equal access to the parking areas and drive aisles. The site improvements may be permitted and constructed independently from the individual buildings.
Site Development Requirements. The following table lists the site development requirements that are applicable within each of the areas at Town Center. Minor variances up to ten percent of 25 the site development requirements may be granted administratively by the City's 25 Development Services Director Land Use Administrator. Other variances may be granted by the City's Planning and Land Development Regulation Board. Table of Site Development Requirements Regulation Town Core Areas Town Service Area Town Business Areas[1] Town Residential Areas Perimeter Commercial Urban Core Urban Center Minimum lot size 2,5001,800 sq. ft. 4,000 sq. ft. 20,000 sq. ft. 20,000 sq. ft. 2,5001,800 sq. ft. 20,000 sq. ft. Minimum lot width 25'18' 40' 100' 100' 25'18' 100' Minimum front yard setback 12' [1][2] 20' 20' 20' 10' [3] 20' [4] 20' Minimum street side setback 12' [1][2] 20' 20' 20' 10' [3] 20' [4] 20' Minimum interior side yard setback 10'[5] 0 [6] 10'[5] 0[6] 10'[5] 0[6] 10'[5] 0[6] 5'[5] 0 [5][6] 10'[5] 0[6] Maximum building height [7] 80' 80' 35' 80' 80' 45'[8] Minimum building height [2][9] 24' 24' 16' 16' 16' 16' Maximum Impervious Coverage per building site 95% [6][10] 85% 85% 85% 75% 85%[11] 35 25 Regulation Town Core Areas Town Service Area Town Business Areas[1] Town Residential Areas Perimeter Commercial Urban Core Urban Center Maximum total impervious coverage for Town Center. 50%
Site Development Requirements. 4.6.1 All requirements not specifically addressed in this Development Agreement shall comply with the Site Development requirements in the City Land Development. 4.6.2 All required improvements set forth in this section shall be provided prior to the issuance of a Certificate of Occupancy for the proposed outparcel building construction.
Site Development Requirements. The Owner agrees that the completion date for all work required pursuant to this agreement shall be , 2018 and provide the Municipality with as constructed drawings.
Site Development Requirements. At its discretion, and after obtaining all necessary permits, the Owner may clear and fill lots within the Development at the time the Development infrastructure improvements are being installed.