Setting Fire Hydrants) Sample Clauses

Setting Fire Hydrants). 6. The outlet connections shall be:
AutoNDA by SimpleDocs
Setting Fire Hydrants). 1. Fire hydrants shall be located as shown on the plans or as otherwise directed so as to provide complete accessibility and minimize the possibility of damage from vehicles or injury to pedestrians. One (1) hydrant shall be set at each street intersection and at the end of every cul‐de‐sac. Intermediate hydrants shall be set so that they are no more than three hundred (300) feet apart in commercial and industrial developments, or five hundred (500) feet apart in residential developments. Distances between fire hydrants shall be measured along roadway centerlines.

Related to Setting Fire Hydrants)

  • Access Toll Connecting Trunk Group Architecture 9.2.1 If CBB chooses to subtend a Verizon access Tandem, CBB’s NPA/NXX must be assigned by CBB to subtend the same Verizon access Tandem that a Verizon NPA/NXX serving the same Rate Center Area subtends as identified in the LERG.

  • Fire Fighting Costs of operating and maintaining the fire-fighting equipments and personnel, if any.

  • Mowing Mowing, edging (of sidewalks, paved approaches and curbs), litter removal, herbicide treatment, grass clipping removal, and brush control are included under one bid item. Regular mowing under this contract is generally limited to mowing areas of shoulders, front and back slopes of ditches less than or equal to three-to-one (3:1) slope, roadside retention areas, dry roadside ditch bottoms, median islands and various width utility strips and similar areas. Slope mowing, which is also a contract requirement, is generally limited to slopes greater or steeper than three-to-one (3:1) and are relatively inaccessible to the use of conventional mowing equipment (e.g., steep slopes, retention area banks and shores, bridge/overpass banks, canal banks, wet roadside ditches, etc). These types of areas will normally require equipment specifically designed for this type of work. When slope mowing is performed, it will incorporate the use of string trimmers to protect the integrity of the slope and prevent damage to the turf. Sign posts, mailboxes, guardrails, trees, roadside outfall structures, fences, divider walls, shrubs, plants, light poles, utility flags or other such obstacles to mowing will be hand mowed or trimmed around as necessary to present a groomed appearance. Top of vegetation on wet bottom ditches areas must be cut-off to the water’s level. Particular attention will be paid to planted areas. Any damage that occurs to plants, trees, shrubs, mulched beds, tree rings, sprinkler heads, etc., will be repaired or restored, at the Contractor’s expense, before the cycle is completed. Mowing will also include grass clipping removal and litter removal, edging, and herbicide treatment. These costs will be included in the unit price bid for right-of-way mowing.

  • Network Interconnection Architecture Each Party will plan, design, construct and maintain the facilities within their respective systems as are necessary and proper for the provision of traffic covered by this Agreement. These facilities include but are not limited to, a sufficient number of trunks to the point of interconnection with the tandem company, and sufficient interoffice and interexchange facilities and trunks between its own central offices to adequately handle traffic between all central offices within the service areas at P.01 grade of service or better. The provisioning and engineering of such services and facilities will comply with generally accepted industry methods and practices, and will observe the rules and regulations of the lawfully established tariffs applicable to the services provided.

  • AIN Selective Carrier Routing for Operator Services, Directory Assistance and Repair Centers 4.3.1 BellSouth will provide AIN Selective Carrier Routing at the request of <<customer_name>>. AIN Selective Carrier Routing will provide <<customer_name>> with the capability of routing operator calls, 0+ and 0- and 0+ NPA (LNPA) 555-1212 directory assistance, 1+411 directory assistance and 611 repair center calls to pre-selected destinations.

  • ROAD DIMENSIONS Purchaser shall perform road work in accordance with the dimensions shown on the TYPICAL SECTION SHEET and the specifications within this road plan.

  • Illumination The Engineer shall refer to TxDOT’s Highway Illumination Manual and other deemed necessary State approved manuals for design of continuous lighting and safety lighting for all conventional, high-mast, and underpass lighting. The Engineer shall include safety lighting as part of each design on each flashing beacon and traffic signal. The Engineer shall provide a preliminary layout for initial review and approval by the State. The Engineer shall prepare circuit wiring diagrams showing the number of luminaries on each circuit, electrical conductors, length of runs, service pole assemblies. Underpass lighting must be used on all structures within each project. The Engineer shall integrate existing illumination within the project limits into the proposed design. The Engineer shall coordinate with the State to determine the location of proposed high- mast, conventional, and underpass lighting.

  • Fire Extinguishers Provide UL-listed extinguishers, cabinets and accessories from a single manufacturer such as X.X. Industries or Xxxxxx’x Manufacturing Company that comply with local fire marshal approval. Extinguishers shall be pressurized solid AFFF Type: UL-rated 3-A: 00X, 0-0/0 xxxxxx xxxxxxx xxxxxxxx, in stainless steel container with pressure indicated gauge. Provide recessed aluminum cabinets with clear anodic coating. DIVISION 11 – EQUIPMENT (deleted) DIVISION 12- FURNISHINGS

  • Configuration Management The Contractor shall maintain a configuration management program, which shall provide for the administrative and functional systems necessary for configuration identification, control, status accounting and reporting, to ensure configuration identity with the UCEU and associated cables produced by the Contractor. The Contractor shall maintain a Contractor approved Configuration Management Plan that complies with ANSI/EIA-649 2011. Notwithstanding ANSI/EIA-649 2011, the Contractor’s configuration management program shall comply with the VLS Configuration Management Plans, TL130-AD-PLN-010-VLS, and shall comply with the following:

  • Outpatient emergency and urgicenter services within the service area The emergency room copay applies to all outpatient emergency visits that do not result in hospital admission within twenty-four (24) hours. The urgicenter copay is the same as the primary care clinic office visit copay.

Time is Money Join Law Insider Premium to draft better contracts faster.