Common use of Selection of Subcontractors Clause in Contracts

Selection of Subcontractors. Contractor shall have the right to have portions of the Work performed by Subcontractors. Subcontractors designated as Major Subcontractors are identified in Exhibit P-1. After the Effective Date, Contractor shall provide periodic updates to the Exhibit P-1 list and shall submit the updated list to Owner for review. Owner shall identify to Contractor any added Major Subcontractors that are unacceptable to Owner and provide to Contractor a reasonable basis for Owner's rejection of any such added Major Subcontractors. Exhibit P-2 contains a list of potential Subcontractors that may be used for Site construction and related field services. Contractor shall work proactively with Owner to choose acceptable Subcontractors for performance of the Work that is not part of the Standard Plant. In the event Contractor desires to use any Subcontractors that are not listed in Exhibit P-2 to conduct its Scope of Work on Owner's property with respect to both the Standard Plant and on work that is not part of the Standard Plant, Contractor shall notify Owner and, within five (5) Business Days of such notice, Owner shall notify Contractor if such proposed Subcontractor is not acceptable to Owner (such acceptance not to be unreasonably withheld). If Owner rejects any such selected Subcontractor and the use of a different Subcontractor would affect Contractor's costs for performance of the Work or the Project Schedule, Contractor shall be entitled to a Change Order pursuant to Article 9. If, however, Owner fails to provide such notice to Contractor within the five (5) Business Day period, then Owner shall be deemed to have approved such proposed Subcontractor. Subject to the prior provisions of this Section 3.7(a) with respect to Major Subcontractors, Contractor is not obligated to consult with Owner on its selection of Subcontractors not working on Owner's property. Owner shall have the right to recommend additions to Exhibit P-1 and P-2 from time to time, subject to Contractor's approval. Contractor shall be responsible for the actions and omissions of all Subcontractors.

Appears in 4 contracts

Samples: Procurement and Construction Agreement (South Carolina Electric & Gas Co), Engineering, Procurement and Construction Agreement, Engineering, Procurement and Construction Agreement

AutoNDA by SimpleDocs

Selection of Subcontractors. In the interest of minimizing the expenditure of funds for the construction of the Project, the Contractor agrees to select appropriately licensed subcontractors for each trade component of the Project in a manner that fosters competition. Contractor agrees that it has solicited or will solicit bids from subcontractors according to a process whereby Contractor publishes a notice of the trade components of the Project [insert timing of publication and newspaper] and enters into competitive bidding negotiations with the potential subcontractors who have successfully participated, or will successfully participate, in Contractor’s pre-qualification process. Further, unless the Parties otherwise agree in writing, on a trade by trade basis, Contractor made or shall make every reasonable effort to ensure that it receives at least three competitive quotes from subcontractors for each trade component of the Project Contractor shall have inform all bidders that the Owner will not be a party to any contracts for construction services executed by the Contractor and selected bidders. However, the Owner reserves the right to have portions oversee the bidding process, and in no case will the Contractor award any subcontracts until the Owner has concurred with the selection, scope, and price of the Work performed by Subcontractorssubcontracted services. Subcontractors designated as Major Subcontractors are identified in Exhibit P-1Contractor shall submit a listing of proposed subcontractors with associated breakdown of bid values to the Owner for the Owner’s review. After In addition, at the Effective DateOwner’s request, Contractor shall provide periodic updates to the Exhibit P-1 list and shall submit Owner with full documentation regarding the updated list to Owner for review. Owner shall identify to Contractor any added Major Subcontractors that are unacceptable to Owner and provide to Contractor a reasonable basis for Owner's rejection of any such added Major Subcontractors. Exhibit P-2 contains a list of potential Subcontractors that may be used for Site construction and related field services. Contractor shall work proactively with Owner to choose acceptable Subcontractors for performance of bids or competitive quotes received by the Work that is not part of the Standard PlantContractor. In no event shall such documentation be redacted or obliterated. If Contractor does not comply with this provision, the event Contractor desires to use any Subcontractors that are not listed Owner may terminate this Agreement in Exhibit P-2 to conduct its Scope accordance with the General Conditions. Following Owner’s concurrence with the selection, scope, and price of Work on Owner's property with respect to both the Standard Plant and on work that is not part of the Standard Plantsubcontracted services, Contractor shall notify Owner and, within five (5) Business Days of such notice, Owner shall notify Contractor if such proposed Subcontractor is not acceptable to Owner (such acceptance not to be unreasonably withheld). If Owner rejects make any such selected Subcontractor and the use of a different Subcontractor would affect Contractor's costs for performance changes in same without Owner’s express written approval of the Work or the Project Scheduleproposed changes, Contractor which approval shall be entitled to a Change Order pursuant to Article 9. If, however, Owner fails to provide such notice to Contractor within the five (5) Business Day period, then Owner shall be deemed to have approved such proposed Subcontractor. Subject to the prior provisions of this Section 3.7(a) with respect to Major Subcontractors, Contractor is not obligated to consult with Owner on its selection of Subcontractors not working on in Owner's property’s sole discretion. Owner shall have reserves the right to recommend additions to Exhibit P-1 and P-2 from time to time, subject to Contractor's approval. terminate this Agreement in accordance with the General Conditions if Contractor shall be responsible for the actions and omissions of all Subcontractorsdoes not comply with this provision.

Appears in 1 contract

Samples: Lease Leaseback Agreement

AutoNDA by SimpleDocs

Selection of Subcontractors. Contractor shall have the right to have portions of the Work performed by Subcontractors. Subcontractors designated as Major Subcontractors are identified in Exhibit P-1. After the Effective Date, Contractor shall provide periodic updates to the Exhibit P-1 list and shall submit the updated list to Owner for review. Owner shall identify to Contractor any added Major Subcontractors that are unacceptable to Owner and provide to Contractor a reasonable basis for Owner's ’s rejection of any such added Major Subcontractors. Exhibit P-2 contains a list of potential Subcontractors that may be used for Site construction and related field services. Contractor shall work proactively with Owner to choose acceptable Subcontractors for performance of the Work that is not part of the Standard Plant. In the event Contractor desires to use any Subcontractors that are not listed in Exhibit P-2 to conduct its Scope of Work on Owner's ’s property with respect to both the Standard Plant and on work that is not part of the Standard Plant, Contractor shall notify Owner and, within five (5) Business Days of such notice, Owner shall notify Contractor if such proposed Subcontractor is not acceptable to Owner (such acceptance not to be unreasonably withheld). If Owner rejects any such selected Subcontractor and the use of a different Subcontractor would affect Contractor's ’s costs for performance of the Work or the Project Schedule, Contractor shall be entitled to a Change Order pursuant to Article 9. If, however, Owner fails to provide such notice to Contractor within the five (5) Business Day period, then Owner shall be deemed to have approved such proposed Subcontractor. Subject to the prior provisions of this Section 3.7(a) with respect to Major Subcontractors, Contractor is not obligated to consult with Owner on its selection of Subcontractors not working on Owner's ’s property. Owner shall have the right to recommend additions to Exhibit P-1 and P-2 from time to time, subject to Contractor's ’s approval. Contractor shall be responsible for the actions and omissions of all Subcontractors.

Appears in 1 contract

Samples: Engineering, Procurement and Construction Agreement (Scana Corp)

Time is Money Join Law Insider Premium to draft better contracts faster.