Sample Collection Procedures Sample Clauses

Sample Collection Procedures. Describe how sampling points will be selected in the field, and how these locations will be documented and marked for future reference. If a sampling grid will be used, describe the dimensions and lay out planned for the grid. Outline sequentially or step-by-step the procedure for collecting a sample for each medium and each different sampling technique. Include a description of sampling equipment (including materials of construction), field measurements, sample preservation, housekeeping/ cleanliness techniques and well purging procedures. The procedure described must ensure that a representative sample is collected, and that sample handling does not result in cross contamination or unnecessary loss of contaminants. Special care in sample handling for volatile organic samples must be addressed. Method 5035 should be used for soil samples that will be analyzed for VOCs by an off- site laboratory. Describe how and when duplicates, blanks, laboratory quality control samples and background samples will be collected. If samples will be filtered, describe filtration equipment and procedures. The Owner/Operator or Respondent must include sufficient maps and tables to fully describe the sampling effort. This shall include, at a minimum, a map showing all proposed sampling locations and tables that contain the following information: Sample Collection Table: Sampling Location/Interval Analytical Parameters (e.g., volatile organic compounds) Analytical Method Number Medium Preservation Method Holding Times (as specified in USEPA SW 846) Containers (quantity, size, type plus footnotes that discuss source and grade of containers) Sample Summary Table: Sample Description/Area (include QC samples) Analytical Parameters Analytical Method Number Preparation or Extraction Method Number Medium Number of Sample Sites
AutoNDA by SimpleDocs
Sample Collection Procedures. Sample collection shall be performed by trained personnel employed by NC DWQ certified laboratories in accordance with the DWQ Monitoring Coalition Program Field Monitoring Guidance Document (December 2012) and subsequent documents. The Field Monitoring Guidance Document can be found on the web at: xxxx://xxxxxx.xxxxxx.xxx/web/wq/ess/eco/coalition. Alternate collection procedures require the approval of the DWQ coalition coordinator prior to use.
Sample Collection Procedures. 9.1 Upon the employee’s consent, the Substance Abuse Administrator, department head, or supervisor shall assure that the employee is taken to a designated sample collection site and provides a urine sample and/or is administered an EBT. Upon a positive EBT, the employee shall provide a blood sample in addition to the required sample of urine.
Sample Collection Procedures. SMC has developed Standard Operating Procedures (SOP) for the collection of monitoring data at the East Boulder Mine that meet standards for best practice with sample collection. These same standards are required for GNA AMP sample collection as described in Section 5 and Appendix A of the East Boulder Mine Water Resources Monitoring Plan (Operational) dated March 2018 and prepared by SMC and Hydrometrics. SMC personnel or contactors responsible for the field collection of water monitoring samples required in this AMP must follow documented, step-by-step procedures for calibration of field equipment, collection of field parameters, collection of water quality samples, and documentation. Separate samples are collected for measurement of field parameters and shipment to the laboratory for analysis. Samples collected for laboratory analysis are stored on ice immediately and preserved according to the analytical method to maintain integrity of the analytical results. Flow rate measurements are collected at the time of sample collection when conditions allow. Detailed field notes are taken at the time of sample collection, including records of field meter calibration, ambient conditions, and measurement of field parameters. Surface water samples are collected as grab samples, with care taken to suspend the sample bottle in the water to avoid entrainment with sediment. Groundwater samples are collected with the use of permanently installed submersible pumps or a portable pump, after the stagnant water is purged from the well casing. Alternatively, in many xxxxx the sample can be collected using a low-flow micro- purge technique. Static water level in the monitoring well is measured prior to sample collection.
Sample Collection Procedures. Describe how sampling points will be selected in the field, and how these locations will be documented and marked for future reference. If a sampling grid will be used, describe the dimensions and layout planned for the grid. Outline sequentially or step-by-step the procedure for collecting a sample for each matrix and each different sampling technique. Include a description of sampling equipment (including materials of construction), field measurements, sample preservation, housekeeping/ cleanliness techniques and well purging procedures. The procedure described must ensure that a representative sample is collected, and that sample handling does not result in cross contamination or unnecessary loss of contaminants. Special care in sample handling for volatile organic samples must be addressed. Described how and when duplicates, blanks, laboratory quality control samples and background samples will be collected. The RFI must include sufficient maps and tables to fully describe the sampling effort. This shall include, at a minimum, a map showing all proposed sampling locations and tables that contain the following information: Sample Collection Table *Sampling Location/Interval *Analytical Parameters (e.g., volatile organic compounds) *Analytical Method Number *Matrix *Preservation Method *Holding Times *Containers (quantity, size, type plus footnotes that discuss source and grade of containers) Sample Summary Table *Sample Description/Area (include QC samples) *Analytical Parameters *Analytical Method Number *Preparation or Extraction Method Number *Matrix *Number of Sample Sites *Number of Analyses
Sample Collection Procedures. Sample collection shall be performed by trained personnel employed by NC DWR-certified laboratories in accordance with the DWR Monitoring Coalition Program Field Monitoring Guidance Document (November 2017) and subsequent documents. The Field Monitoring Guidance Document can be found on the web at: xxxx://xxx.xx.xxx/about/divisions/water-resources/water-resources-data/water-sciences- home-page/ecosystems-branch/monitoring-coalition-program. Alternate collection procedures require the approval of the DWR Coalition Coordinator prior to use.
Sample Collection Procedures 
AutoNDA by SimpleDocs

Related to Sample Collection Procedures

  • Selection Procedures In selecting the Loan Assets to be Pledged pursuant to this Agreement, no selection procedures were employed which are intended to be adverse to the interests of the Lenders.

  • Election Procedures Each holder of record of shares of Company Common Stock (“Holder”) shall have the right, subject to the limitations set forth in this Article II, to submit an election in accordance with the following procedures: