Project Design and Performance Verification Studies Sample Clauses

Project Design and Performance Verification Studies. In accordance with Article 24.4, Developer shall perform project design and performance verification studies and shall provide design and performance verification study reports to the Connecting Transmission Owner and to the NYISO. Connecting Transmission Owner shall be free to witness any simulator demonstrations that are relevant to system performance. The minimum design and performance verification studies are summarized as follows:
AutoNDA by SimpleDocs
Project Design and Performance Verification Studies. In accordance with Article 24.4, Developer shall perform project design and performance verification studies and shall provide design and performance verification study reports to the Connecting Transmission Owner and to the NYISO. Connecting Transmission Owner shall be free to witness any simulator demonstrations that are relevant to system performance. The minimum design and performance verification studies are summarized as follows: Project main circuit design study; Dynamic performance study including AC system tolerance and disturbance recovery performance verification, as further detailed in Appendix G, section 5.6.8; Steady-state reactive power flow exchange verification; AC system harmonic performance verification study; Power line carrier (“PLC”) performance verification study; Temporary overvoltage and insulation coordination studies; 345kV circuit breaker coordination study; AC and DC protection system study; Sub-synchronous torsional interaction screening and control; Implementation studies; Additional electromagnetic transients program studies, as necessary to validate system performance based on final design. APPENDIX D SECURITY ARRANGEMENTS Infrastructure security of New York State Transmission System equipment and operations and control hardware and software is essential to ensure day-to-day New York State Transmission System reliability and operational security. The Commission will expect the NYISO, all Transmission Owners, all Developers and all other Market Participants to comply with the recommendations offered by the President’s Critical Infrastructure Protection Board and, eventually, best practice recommendations from the electric reliability authority. All public utilities will be expected to meet basic standards for system infrastructure and operational security, including physical, operational, and cyber-security practices. APPENDIX E COMMERCIAL OPERATION DATE [Date] New York Independent System Operator, Inc. Attn: Vice President, Operations 0000 Xxxxxx Xxxx Schenectady, NY 12303 Phone: (000) 000-0000 Fax: (000) 000-0000 Consolidated Edison Company of New York, Inc. 0 Xxxxxx Xxxxx Xxx Xxxx, XX 00000 Attn: Senior Vice President, System and Transmission Operations Phone: (000) 000-0000 Fax: (000) 000-0000 Re: Xxxxxx Transmission Partners, LLC Merchant Transmission Facility Dear __________________: On [Date] [Developer] has completed Trial Operation. This letter confirms that [Developer] commenced Commercial Operation of the Merchant...

Related to Project Design and Performance Verification Studies

  • Registry Performance Specifications Registry Performance Specifications for operation of the TLD will be as set forth in Specification 10 attached hereto (“Specification 10”). Registry Operator shall comply with such Performance Specifications and, for a period of at least one (1) year, shall keep technical and operational records sufficient to evidence compliance with such specifications for each calendar year during the Term.

  • Continuity of Service and Performance Unless otherwise agreed in writing, the Parties shall continue to provide service and honor all other commitments under this Agreement during the course of a Dispute with respect to all matters not subject to such Dispute.

  • CONTRACTOR PERFORMANCE AUDIT The Contractor shall allow the Authorized User to assess Contractor’s performance by providing any materials requested in the Authorized User Agreement (e.g., page load times, response times, uptime, and fail over time). The Authorized User may perform this Contractor performance audit with a third party at its discretion, at the Authorized User’s expense. The Contractor shall perform an independent audit of its Data Centers, at least annually, at Contractor expense. The Contractor will provide a data owner facing audit report upon request by the Authorized User. The Contractor shall identify any confidential, trade secret, or proprietary information in accordance with Appendix B, Section 9(a), Confidential/Trade Secret Materials.

  • Portfolio Expense and Performance Data The Fund shall provide such data regarding each Portfolio’s expense ratios and investment performance as the Company shall reasonably request, to facilitate the registration and sale of the Variable Contracts. Without limiting the generality of the forgoing, the Fund shall provide the following Portfolio expense and performance data on a timely basis to facilitate the Company’s preparation of its annually updated registration statement for the Variable Contracts (and as otherwise reasonably requested by the Company), but in no event later than 75 calendar days after the close of each Portfolio’s fiscal year:

  • Project/Milestones Taxpayer provides refrigerated warehousing and logistic distribution services to clients throughout the United States. In consideration for the Credit, Taxpayer agrees to invest in a new refrigeration and distribution facility in the XxXxxxxxx Park area of Sacramento, California, and hire full-time employees (collectively, the “Project”). Further, Taxpayer agrees to satisfy the milestones as described in Exhibit A (“Milestones”) and must maintain Milestones for a minimum of three (3) taxable years thereafter. In the event Taxpayer employs more than the number of full-time employees, determined on an annual full-time equivalent basis, than required in Exhibit A, for purposes of satisfying the “Minimum Annual Salary of California Full-time Employees Hired” and the “Cumulative Average Annual Salary of California Full-time Employees Hired,” Taxpayer may use the salaries of any of the full-time employees hired within the required time period. For purposes of calculating the “Minimum Annual Salary of California Full-time Employees Hired” and the “Cumulative Average Annual Salary of California Full-time Employees Hired,” the salary of any full-time employee that is not employed by Taxpayer for the entire taxable year shall be annualized. In addition, the salary of any full-time employee hired to fill a vacated position in which a full-time employee was employed during Taxpayer’s Base Year shall be disregarded.

  • Inspection Testing Authorization and Right of Access 2.1 Equipment Testing and Inspection 2.2 Authorization Required Prior to Parallel Operation

  • Project Deliverables The Contractor shall provide each of the following deliverables in writing to the City for review and approval to achieve the project objectives.

  • Hardware and Software Requirements In order to access and retain Disclosures electronically, you must satisfy the following computer hardware and software requirements: access to the Internet; an email account and related software capable of receiving email through the Internet; a web browser which is SSL-compliant and supports secure sessions, and hardware capable of running this software.

  • Software Performance HP warrants that its branded software products will conform materially to their specifications and be free of malware at the time of delivery. HP warranties for software products will begin on the date of delivery and unless otherwise specified in Supporting Material, will last for ninety (90) days. HP does not warrant that the operation of software products will be uninterrupted or error-free or that software products will operate in hardware and software combinations other than as authorized by HP in Supporting Material.

  • DTC DIRECT REGISTRATION SYSTEM AND PROFILE MODIFICATION SYSTEM (a) Notwithstanding the provisions of Section 2.4 of the Deposit Agreement, the parties acknowledge that DTC’s Direct Registration System (“DRS”) and Profile Modification System (“Profile”) apply to the American Depositary Shares upon acceptance thereof to DRS by DTC. DRS is the system administered by DTC that facilitates interchange between registered holding of uncertificated securities and holding of security entitlements in those securities through DTC and a DTC participant. Profile is a required feature of DRS that allows a DTC participant, claiming to act on behalf of an Owner of American Depositary Shares, to direct the Depositary to register a transfer of those American Depositary Shares to DTC or its nominee and to deliver those American Depositary Shares to the DTC account of that DTC participant without receipt by the Depositary of prior authorization from the Owner to register that transfer.

Time is Money Join Law Insider Premium to draft better contracts faster.