Common use of POLE MOUNTED Clause in Contracts

POLE MOUNTED. For pole mounted box connected to underground service, Contractor shall furnish and install 2" service conduit with capped service bend between a point 18' below sidewalk level and bottom line of box. Conduit shall be secured to post or pole with pipe straps, by wood screws. Bottom wall of box shall be drilled, if necessary, and box set on 2" service conduit, placed in proper position on pole (cut gain in pole if necessary) and securely fastened pole with four (4) 3/8 x 2" lag screws. Conduit and condulet between box and lighting unit shall be secured with pipe straps and round head wood screws (1-1/2 x #10). The end of conduit at bracket of lighting unit shall be provided with a condulet fitting which shall be connected to wireway of bracket. Where necessary, Contractor shall drill and tap hub casting of bracket to receive condulet fitting.

Appears in 2 contracts

Sources: Furnish and Install Agreement, Furnish and Install Agreement

POLE MOUNTED. For pole mounted box connected to underground service, Contractor shall furnish and install 2" service conduit with capped service bend between a point 18' below sidewalk level and bottom line of box. Conduit shall be secured to post or pole with pipe straps, by wood screws. Bottom wall of box shall be drilled, if necessary, and box set on 2" service conduit, placed in proper position on pole (cut gain in pole if necessary) and securely fastened pole with four (4) 3/8 x 2" lag screws. Conduit and condulet between box and lighting unit shall be secured with pipe straps and round head wood screws (1-1- 1/2 x #10). The end of conduit at bracket of lighting unit shall be provided with a condulet fitting which shall be connected to wireway of bracket. Where necessary, Contractor shall drill and tap hub casting of bracket to receive condulet fitting.

Appears in 1 contract

Sources: Furnish and Install Agreement

POLE MOUNTED. For pole mounted box connected to underground service, Contractor shall furnish and install 2" service conduit with capped service bend between a point 18' below sidewalk level and bottom line of box. Conduit shall be secured to post or pole with pipe straps, by wood screws. Bottom wall of box shall be drilled, if necessary, and box set on 2" service conduit, placed in proper position on pole (cut gain in pole if necessary) and securely fastened pole with four (4) 3/8 x 2" lag screws. Conduit and condulet between box and lighting unit shall be secured with pipe straps and round head wood screws (1-1/2 x #10). .) The end of conduit at bracket of lighting unit shall be provided with a condulet fitting which shall be connected to wireway of bracket. Where necessary, Contractor shall drill and tap hub casting of bracket to receive condulet fitting.

Appears in 1 contract

Sources: Furnish and Install Agreement