Common use of Maintenance Programme Clause in Contracts

Maintenance Programme. 17.4.1 On or before Project COD and no later than 45 (forty-five) days prior to the beginning of each Accounting Year during the Operation Period, as the case may be, the Concessionaire shall provide to the Authority and the Independent Expert, its proposed annual programme of preventive, urgent and other scheduled maintenance (the “Maintenance Programme”) to comply with the Maintenance Requirements, Maintenance Manual and EHS Requirement. Such Maintenance Programme shall include: (a) preventive maintenance schedule; (b) arrangements and procedures for carrying out urgent repairs; (c) criteria to be adopted for deciding maintenance needs; (d) intervals and procedures for carrying out inspection of all elements of the Project; (e) intervals at which the Concessionaire shall carry out periodic maintenance; (f) arrangements and procedures for carrying out safety related measures; (g) intervals for major maintenance works and the scope thereof; and (h) frequency of carrying out intermediate and periodic overhaul of electrical, mechanical and other systems. 17.4.2 Within 15 (fifteen) days of receipt of the Maintenance Programme, the Independent Expert shall review the same and convey its comments to the Concessionaire with particular reference to its conformity with the Maintenance Requirements, Maintenance Manual and EHS Requirements. 17.4.3 The Concessionaire may modify the Maintenance Programme as may be reasonable in the circumstances, and the procedure specified in Clauses 17.4.1 and 17.4.2 shall apply mutatis mutandis to such modifications.

Appears in 2 contracts

Sources: Concession Agreement, Concession Agreement

Maintenance Programme. 17.4.1 16.4.1 On or before Project COD and no later than 45 (forty-forty five) later than days prior to the beginning of each Accounting Year during the Operation Concession Period, as the case may be, the Concessionaire shall provide to the Authority and the Independent ExpertEngineer(s), its proposed annual programme program of preventive, urgent and other scheduled maintenance (the "Maintenance Programme") to comply with the Maintenance Requirements, Maintenance Manual and EHS RequirementSafety Requirements. Such Maintenance Programme shall include: (a) preventive maintenance schedule; (b) arrangements and procedures for carrying out urgent repairsrepairs and regular wear & tear of the equipment installed by the Concessionaire; (c) criteria to be adopted for deciding maintenance needs; (d) intervals and procedures for carrying out inspection of all elements of the Project; (e) intervals at which the Concessionaire shall carry out periodic maintenance; (f) arrangements and procedures for carrying out safety related measures;; and (g) intervals Intervals for major maintenance works and the scope thereof; and (h) frequency of carrying out intermediate and periodic overhaul of electrical, mechanical and other systems. 17.4.2 16.4.2 Within 15 (fifteen) days of receipt of the Maintenance Programme, the Independent Expert Engineer(s) shall review the same and convey its comments to the Concessionaire with particular reference to its conformity with the Maintenance Requirements, Maintenance Manual and EHS Safety Requirements. 17.4.3 16.4.3 The Concessionaire may modify the Maintenance Programme as may be reasonable in the circumstances, and the procedure specified in Clauses 17.4.1 Articles 16.4.1 and 17.4.2 16.4.2 shall apply mutatis mutandis to such modifications.

Appears in 1 contract

Sources: Concession Agreement

Maintenance Programme. 17.4.1 On or before Project COD and no Not later than 45 (forty-five) days prior to the beginning of each Accounting Year during the Operation Period, as the case may be, the Concessionaire shall provide to the Authority and the Independent Expert, its proposed annual programme of preventive, urgent and other scheduled maintenance (the “Maintenance Programme”) to comply with the Maintenance Requirements, Service Requirements, Service Quality Manual, Maintenance Manual and EHS RequirementSafety Requirements. Such Maintenance Programme shall include: (a) preventive maintenance schedule; (b) routine maintenance schedule; (c) arrangements and procedures for carrying out urgent repairs; (cd) criteria to be adopted for deciding maintenance needs; (de) intervals and procedures for carrying out inspection of all elements of the Project; (ef) intervals at which the Concessionaire shall carry out periodic maintenance; (fg) arrangements and procedures for carrying out safety related measures; (gh) intervals for major maintenance works and the scope thereof; and (hi) frequency of carrying out intermediate and periodic overhaul of electrical, mechanical and other systemsthe equipment. 17.4.2 Within 15 (fifteen) days of receipt of the Maintenance Programme, the Independent Expert shall review the same and convey its comments to the Concessionaire with particular reference to its conformity with the Service Requirements and Maintenance Requirements, Service Quality Manual, Maintenance Manual and EHS Safety Requirements. 17.4.3 The Concessionaire may modify the Maintenance Programme as may be reasonable in the circumstances, and the procedure specified in Clauses 17.4.1 and 17.4.2 shall apply mutatis mutandis to such modifications.

Appears in 1 contract

Sources: Concession Agreement

Maintenance Programme. 17.4.1 On or before Project COD and no later than 45 (forty-forty five) days prior to the beginning of each Accounting Year during the Operation Period, as the case may be, the Concessionaire shall provide to the Authority Government and the Independent ExpertEngineer, its proposed annual programme of preventive, urgent and other scheduled maintenance (the “Maintenance Programme”) to comply with the Maintenance Requirements, Maintenance Manual and EHS RequirementSafety Requirements. Such Maintenance Programme shall include: (a) preventive maintenance schedule; (b) arrangements and procedures for carrying out urgent repairs; (c) criteria to be adopted for deciding maintenance needs; (d) intervals and procedures for carrying out inspection of all elements of the ProjectRail System; (e) intervals at which the Concessionaire shall carry out periodic maintenance; (f) arrangements and procedures for carrying out safety related measures; (g) intervals for major maintenance works and the scope thereof; and (h) frequency intervals of carrying out intermediate and periodic overhaul of electricalrolling stock, mechanical track and other systemsTraction System. 17.4.2 Within 15 (fifteen) days of receipt of the Maintenance Programme, the Independent Expert Engineer shall review the same and convey its comments to the Concessionaire with particular reference to its conformity with the Maintenance Requirements, Maintenance Manual and EHS Safety Requirements. 17.4.3 The Concessionaire may modify the Maintenance Programme as may be reasonable in the circumstances, and the procedure specified in Clauses 17.4.1 and 17.4.2 shall apply mutatis mutandis to such modifications.

Appears in 1 contract

Sources: Concession Agreement