Hybrid capture Sample Clauses

Hybrid capture. The PCR plate was kept at 65 oC while the hybridization mixture was added from the thermal cycler to the bead solution and the plate was sealed and mixed by inverting it x5 times. Minimal evaporation was essential. The hybrid-capture/bead solution was incubated on a heat block for 30 minute at room temperature and the mix was briefly spanned in a centrifuge. The beads and buffer were separated on the Dynal magnetic separator and the supernatant was removed. The beads were re-suspended in 500 μl of SureSelect Wash Buffer #1 and vortexed for 5 seconds. The samples were incubated for 15 minutes at room temperature and occasionally vortexed. Beads and buffer were again separated on the Dynal magnetic separator and the supernatant was removed. The beads were re-suspended in 500 μl of 65 oC prewarmed SureSelect Wash Buffer #2 and mixed on a vortex for 5 seconds. The samples were incubated for 10 minutes at 65 oC and briefly spun in a centrifuge (<3 seconds). The beads and buffer were separated on the Dynal magnetic separator and the supernatant was removed over a total of 3 washes. The beads were mixed in 50 μl of SureSelect Elution Buffer on a vortex mixer for 5 seconds and samples were incubated at room temperature for 10 minutes. The beads and buffer were separated on the Dynal magnetic separator and the supernatant containing the captured DNA was transferred to a new 1.5 ml microfuge tube. 50 μl of SureSelect Neutralization Buffer were added to the captured DNA.
AutoNDA by SimpleDocs

Related to Hybrid capture

  • Hybrid Loop A Loop composed of both fiber optic cable and copper wire or cable. An FTTP Loop is not a Hybrid Loop.

  • Hybrid Loops Sprint will provide CLEC access to Hybrid Loops for the provision of narrowband services as provided below. Sprint is not required to provide unbundled access to the packet switched features, functions, and capabilities of its Hybrid Loops.

  • Testing Capabilities 7.2.2.10.2.1 LIS Acceptance Testing is provided where equipment is available, with the following test lines: seven-digit access to balance (100 type), milliwatt (102 type), nonsynchronous or synchronous, automatic transmission measuring (105 type), data transmission (107 type), loop-around, short circuit, open circuit, and non-inverting digital loop-back (108 type), and such other acceptance testing that may be needed to ensure that the service is operational and meets the applicable technical parameters.

  • Local Circuit Switching Capability, including Tandem Switching Capability 4.2.1 Local circuit switching capability is defined as: (A) line-side facilities, which include, but are not limited to, the connection between a loop termination at a main distribution frame and a switch line card; (B) trunk-side facilities, which include, but are not limited to, the connection between trunk termination at a trunk-side cross-connect panel and a switch trunk card; (C) switching provided by remote switching modules; and (D) all features, functions, and capabilities of the switch, which include, but are not limited to: (1) the basic switching function of connecting lines to lines, line to trunks, trunks to lines, and trunks to trunks, as well as the same basic capabilities made available to BellSouth’s customers, such as a telephone number, white page listings, and dial tone; and (2) all other features that the switch is capable of providing, including but not limited to customer calling, customer local area signaling service features, and Centrex, as well as any technically feasible customized routing functions provided by the switch. Any features that are not currently available but are technically feasible through the switch can be requested through the BFR/NBR process.

  • Unbundled Channelization (Multiplexing) 5.7.1 To the extent NewPhone is purchasing DS1 or DS3 or STS-1 Dedicated Transport pursuant to this Agreement, Unbundled Channelization (UC) provides the optional multiplexing capability that will allow a DS1 (1.544 Mbps) or DS3 (44.736 Mbps) or STS-1 (51.84 Mbps) Network Elements to be multiplexed or channelized at a BellSouth central office. Channelization can be accomplished through the use of a multiplexer or a digital cross-connect system at the discretion of BellSouth. Once UC has been installed, NewPhone may request channel activation on a channelized facility and BellSouth shall connect the requested facilities via COCIs. The COCI must be compatible with the lower capacity facility and ordered with the lower capacity facility. This service is available as defined in NECA 4.

  • Packet Switching Capability 4.5.1 The packet switching capability network element is defined as the function of routing or forwarding packets, frames, cells or other data units based on address or other routing information contained in the packets, frames, cells or other data units.

  • Mileage Measurement Where required, the mileage measurement for LIS rate elements is determined in the same manner as the mileage measurement for V&H methodology as outlined in NECA Tariff No. 4.

  • WORKING TEST PERIOD Section One. The Working Test Period shall be deemed an extension of the examination process. Therefore, a determination of unsatisfactory performance during a Working Test Period shall be tantamount to a failure of the competitive exam.

  • Therapist Availability Therapist’s office is equipped with a confidential voice mail system that allows Patient to leave a message at any time. Therapist will make every effort to return calls within 24 hours (or by the next business day), but cannot guarantee the calls will be returned immediately. Therapist is unable to provide 24-hour crisis service. In the event that Patient is feeling unsafe or requires immediate medical or psychiatric assistance, he/she should call 911, or go to the nearest emergency room.

  • Measuring EPP parameters Every 5 minutes, EPP probes will select one “IP address” of the EPP servers of the TLD being monitored and make an “EPP test”; every time they should alternate between the 3 different types of commands and between the commands inside each category. If an “EPP test” result is undefined/unanswered, the EPP service will be considered as unavailable from that probe until it is time to make a new test.

Time is Money Join Law Insider Premium to draft better contracts faster.