GAS SPECIFICATION. (a) All Gas supplied by User at a Receipt Point must: (i) conform with the specification set down in AS 4564 “Australian Standard Specification for General Purpose Natural Gas”; (ii) not contain more than 5% by volume of carbon dioxide; (iii) not have a water vapour content of more than sixty milligrams per cubic metre (60 mg/m3) or as otherwise advised by Service Provider; and (iv) not exceed seventy two degrees (72°C) in temperature, provided that at no time may the Gas Specification be of a lesser standard than that required by law (Gas Specification). (b) For the avoidance of doubt, User acknowledges and agrees that in order to conform with the Gas Specification the Gas must not contain: (i) materials, dust or other solid or liquid matter, waxes, gums, gum forming constituents, and unsaturated or aromatic hydrocarbons to an extent which might cause damage to, or interfere with the proper operation of, pipes, meters, regulators, control systems, equipment or appliances or which might cause the Gas to be harmful or toxic to persons having contact with it in normal work operations or usage; (ii) unsaturated or aromatic hydrocarbons to an extent that causes unacceptable sooting; or (iii) other substances to the extent that they cause damage to, or problems in operation of, pipelines or appliances or that cause the products of combustion to be toxic, or hazardous to health, other than substances that are usually found in natural Gas combustion products. (c) For the purpose of the Gas Specification, carbon dioxide is an inert gas.
Appears in 2 contracts
Sources: Gas Transportation Agreement, Gas Transportation Agreement
GAS SPECIFICATION. (a) All User must ensure that all Gas supplied by User it supplies at a Receipt Point must:
(i) conform conforms with the specification set down in AS 4564 “"Australian Standard Specification for General Purpose Natural Gas”;", and in the case of:
(iii) the Moomba Gas Plant Receipt Point:
(A) is at a temperature of not contain greater than 71˚C; and
(B) contains not more than 53% by volume of carbon dioxide;
(iii) not have a water vapour content of more than sixty milligrams per cubic metre (60 mg/m3) or as otherwise advised by Service Provider; and
(ivii) the QSN Receipt Point, is at a temperature of not exceed seventy two degrees (72°C) in temperaturegreater than 50˚C, provided that the Gas Specification at no time may the Gas Specification be is of a lesser standard than that required by law (Gas Specification).
(b) For the avoidance of doubt, User acknowledges and agrees that in order to conform with the Gas Specification the Gas must not contain:
(i) materials, dust or other solid or liquid matter, waxes, gums, gum forming constituents, and unsaturated or aromatic hydrocarbons to an extent which might cause damage to, or interfere with the proper operation of, pipes, meters, regulators, control systems, equipment or appliances or which might cause the Gas to be harmful or toxic to persons having contact with it in normal work operations or usage;
(ii) unsaturated or aromatic hydrocarbons to an extent that causes unacceptable sooting; or
(iii) other substances to the extent that they cause damage to, or problems in operation of, pipelines or appliances or that cause the products of combustion to be toxic, or hazardous to health, other than substances that are usually found in natural Gas combustion products.
(c) For the purpose of the Gas Specification, carbon dioxide is an inert gas.
Appears in 1 contract
Sources: Gas Transportation Agreement