Galvanized Sample Clauses

Galvanized. Steel Sheet: Hot-dip, zinc-coated steel sheet complying with ASTM A 653/A 653M, G60 (Z180) coating designation.
Galvanized. Attic ventilation None and solid soffit with 6" overhang. Interior divide walls 2 x 8 T&G PVC Planking Hallway walls 2 x 4 Frame with PPD with 3/8" backing and SS nails and trims. CONCRETE SPECIFICATIONS: Shallow footings 8" x 12" Footer. 6" perimeter stem wall with 3' OC vertical #3 rebar and 2 horizontal #3 rebar. Two horizontal rebar one below and one above grade. Vertical rebar to be 3' OC #3. Floors 3 1/2" to 4" thick Footings and pit walls and floors to be 3000PSI concrete and walk floors to be 3500PSI concrete. All flush pits 16" in depth sloped as per customer request. ELECTRICAL SPECIFICATIONS: 1-200 amp main interior 42 space panel. 206 22W McGill lights 206-120V duplex receptacles at Owner's option and 2-220V receptacles at Owner's option. Other electrical to ventilation, heaters and feed systems as required. All electrical in carlon or equal. PLUMBING SPECIFICATIONS: All plumbin▇ ▇▇ ▇e PVC. One run of 2" mainline with pressure reducers for nipple drops and 1" hi-volume line with 4 drops per room.
Galvanized steel PV module support and racking system support posts shall be removed and disposed off-site by an approved facility.
Galvanized steel 8D nails shall be used when placing structural-use panels, and galvanized steel 16D when placing furring strips. Galvanized self-tapping No.10 screws, 2 ½ inches long, with gimlet point should only be used when it becomes necessary to anchor a furring strip directly to corrugated roofing where there is not an existing rafter underneath to anchor into. All fasteners shall be installed every twenty-four (24) inches on center along the panel or furring strip. Corrugated roofs may require 3 1/2 –inch fasteners. The Contractor shall furnish and install fasteners of sufficient length to ensure a good connection.
Galvanized. Attic ventilation Ridge vents and solid soffit 16" overhang. Air chamber inlet room As per standard specifications Curtain openings Screened but bird wire and interior base of hog panel galvanized. CONCRETE SPECIFICATIONS: Shallow footings 6" x 36" trenched. 24" x 6" perimeter stem wall with 3' OC vertical #3 rebar and 2 horizontal #3 rebar. Two horizontal rebar one below and one above grade. Vertical rebar to be 3' OC #3. Floors 3 1/2" to 4" thick Footings and pit walls and floors to be 3000PSI concrete and walk floors to be 3500PSI concrete. Wire mesh in all floor areas. All flush pits 16" -24" in depth sloped as per customer request. ELECTRICAL SPECIFICATIONS: 1-200 amp main interior 42 space panel. 100 22W McGill lights with florescent fixtures 4 rows of 12, 3 120V receptacles at Owner's option and 1-220V receptacles at Owner's option. Other electrical to ventilation, heaters and feed systems as required. All electrical in carlon or equal. PLUMBING SPECIFICATIONS: All plumbin▇ ▇▇ ▇e PVC. 2" PVC mainline. Soaker system in breeding squares. 6 runs of 1" high volume line with 4 drops per line. 2 boiler drains. 6" recycle line with one drop per pit.
Galvanized. Attic ventilation Ridge vents and vented soffit 12" overhang. Floor covering Commercial tile OWNER'S color choice-Office Vinyl base trims. All front office areas and rest rooms and shower areas. Floor covering Storage area, AI lab and utility room unpainted concrete. CONCRETE SPECIFICATIONS: Footings 6" x 36" Footing. Two horizontal rebar one below and one above grade. Vertical rebar to be 3' OC #3. Floors 3 1/2" to 4" thick All concrete to be 3500PSI concrete. One exterior 6' x 4' stoop areas with boot scraper. ELECTRICAL SPECIFICATIONS: 150 amp main interior 30 space panel to handle office area. 14-4' 4 tube fluorescent lights in office/AI area. 2-8' 2 tube fluorescent lights in boot room. 14-4' 2 tube fluorescent lights in bathroom, shower rooms, utility room and rest rooms. Incandescent lights in storage/utility areas. 1-exterior 175w security fixture at building entrance. All electrical outlets in shower areas and bathrooms to be ground fault interruption style. Standard residential wiring codes. PLUMBING SPECIFICATIONS: All plumbing to be PVC installed and vented as required to meet codes. Larger Shop drain with grate 12" x 12". Septic system and drain field by OWNER.
Galvanized after finishing the machining and marking, all parts of iron and steel will be galvanized through hot dip according to ASTM A 153 standard.
Galvanized. Steel Items: Plated steel fasteners complying with ASTM B 633, Class Fe/Zn 25 for electrodeposited zinc coating.
Galvanized. ASTM A36, hot-dip zinc coated per ASTM A153, Class C or mechanically