Design Basis Report. Consultant shall provide a narrative report describing for each design discipline its the rationale for the proposed systems. Disciplines shall include architectural, structural, mechanical, electrical, electronics and security systems, types of equipment, materials and finishes, and site development and landscaping. The rationale shall include initial costs, lifecycle costs, life expectancy and maintenance considerations. The design basis report shall include, for major building systems or components, i.e. those comprising 25% of all building systems or components, a description of the top two or three options considered, an evaluation of their pros and cons and why the preferred option is recommended.
Design Basis Report. 1.1 Hold project kick-off meeting to review project scope and schedule, introduce key team members, and discuss design concepts and goals. 1.2 Review existing information provided by Owner including existing drawings, property information, water use records, industry growth projections, and records to determine a reasonable future capacity for the pump station. 1.3 Evaluate the two force main alignments presented in the facility plan, and up to one (1) additional alignment. Evaluation of the alignments presented in the facility plan will consider alternative pump station sites and modifications to the alignments that may better serve potential development in the existing farmland area northeast of the intersection of Interstate 280 and West Locust Street. Evaluate up to three (3) alignments for the gravity sewer from the intersection of Interstate 280 and West Locust Street to existing manhole WD- 37 east of Utah Avenue. 1.4 Develop hydraulic calculations to determine pump size, wet well size, and force main size for each of the two force main alignments. 1.5 Coordinate with Iowa DOT to confirm casing requirements within DOT right-of-way. 1.6 Develop a planning level opinion of probable construction cost for pump station, force main route alternatives, and lagoon abandonment. 1.7 Summarize information into a Design Basis Report, and provide recommendations for the pump station location and force main alignment. 1.8 Perform quality control check on the Design Basis Report. 1.9 Submit digital (PDF) copy of Design Basis Report to the Owner for review. 1.10 Attend Design Basis Report review meeting. 1.11 Incorporate Owner comments to finalize Design Basis Report. 1.12 Submit digital (PDF) copy of final Design Basis Report to the Owner.
Design Basis Report. Consultant shall provide a brief narrative report by each design discipline describing its proposed design philosophy with a description of, and the rationale for the proposed structural systems, mechanical systems, electrical, electronics and security systems, types of equipment, materials and finishes, site development and landscaping as required by the Project.