Component based test. 3.2.1. The REESS shall be in good mechanical condition and have been subject to minimum of 5 standard cycles (as specified in Annex 8, Appendix 1). 3.2.2. If the REESS is used at a temperature above the ambient temperature, the operator shall follow the manufacturer's procedure in order to keep the REESS temperature in its normal functioning range. The manufacturer's representative shall be able to certify that the temperature conditioning system of the REESS is neither damaged nor presenting a capacity defect Figure 7.1 START Vehicle/REESS preparation (if necessary) Discharge of the REESS Ambient temperature of 293 to 303 K 12 to 36 h Soak Hydrogen emission test during a normal charge Discharge of the REESS Ambient temperature of 293 to 303 K 12 to 36 h Soak END
Appears in 1 contract
Sources: Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles
Component based test. 3.2.1. The REESS shall be in good mechanical condition and have been subject to minimum of 5 standard cycles (as specified in Annex 8, Appendix 1).
3.2.2. If the REESS is used at a temperature above the ambient temperature, the operator shall follow the manufacturer's procedure in order to keep the REESS temperature in its normal functioning range. The manufacturer's representative shall be able to certify that the temperature conditioning system of the REESS is neither damaged nor presenting a capacity defect Figure 7.1 START Vehicle/REESS preparation (if necessary) Discharge of the REESS Ambient temperature of 293 to 303 K 12 to 36 h Soak Hydrogen emission test during a normal charge Discharge of the REESS Ambient temperature of 293 to 303 K 12 to 36 h Soak ENDEND Maximum 15 min nly Public CommenOt
Appears in 1 contract
Sources: Agreement Concerning the Adoption of Uniform Technical Prescriptions for Wheeled Vehicles