Additional test Clause Samples

Additional test. 2.5.1. If the power-driven vehicle is equipped with one or more energy storage devices for auxiliary equipment having a total capacity exceeding 20 per cent of the total capacity of the braking energy storage devices, an additional test shall be performed during which no irregularity shall occur in the operation of the valves controlling the filling of the energy storage device(s) for auxiliary equipment. 2.5.2. It shall be verified during the aforesaid test that the time t3 necessary to raise the pressure from 0 to p2 in the least-favoured braking energy storage device is less than:
Additional test. 2.5.1. If the power-driven vehicle is equipped with one or more energy storage devices for auxiliary equipment having a total capacity exceeding 20 per cent of the total capacity of the braking energy storage devices, an additional test shall be performed during which no irregularity shall occur in the operation of the valves controlling the filling of the energy storage device(s) for auxiliary equipment. 2.5.2. It shall be verified during the aforesaid test that the time t3 necessary to raise the pressure from 0 to p2 in the least-favoured braking energy storage device is less than: 2.5.2.1. Eight minutes in the case of vehicles to which the coupling of a trailer is not authorized; or 2.5.2.2. Eleven minutes in the case of vehicles to which the coupling of a trailer is authorized. 2.5.3. The test shall be performed in the conditions prescribed in paragraphs 2.3.1. and 2.3.3. above.
Additional test. One detector of each type will be disconnected and subjected to slow dust build - up by means as desired by the Consultant/client and again connected in the circuit. Any part of the Loop shall be short circuited. The FACP shall indicate the communication failure of all the devices connected in the short circuited segment. After the short circuit is corrected, the Fault Isolator shall return to its normal status automatically, this being reflected in the FACP. The Loop shall then be in normal operation again. Any part of the Loop shall be de wired and tested as given above for open fault. All other tests as required by the client at the time of handing over shall also to be conducted
Additional test. 2.5.1. If the power-driven vehicle is equipped with one or more energy storage devices for auxiliary equipment having a total capacity exceeding 20 per cent of the total capacity of the braking energy storage devices, an additional test shall be performed during which no irregularity shall occur in the operation of the valves E/ECE/324 Rev.1/Add.12/Rev.4 Regulation No. 13 page 86 Annex 7 controlling the filling of the energy storage device(s) for auxiliary equipment. 2.5.2. It shall be verified during the aforesaid test that the time t3 necessary to raise the pressure from 0 to p2 in the least-favoured braking energy storage device is less than: 2.5.2.1. Eight minutes in the case of vehicles to which the coupling of a trailer is not authorized; or 2.5.2.2. Eleven minutes in the case of vehicles to which the coupling of a trailer is authorized. 2.5.3. The test shall be performed in the conditions prescribed in paragraphs 2.3.1. and 2.3.3. above.