Examples of HCU 942 in a sentence
The following meters shall be used as input to the above calculations: Light Cycle Oil to HCU 942: XX-XXXX Heavy Gas Oil from DCU 843 to HCU 942: DCU 843 FE-1000 Heavy Gas Oil from AVU 146 & Light Cycle Oil to HCU 942: HCU 942 FQ-1020 Quality Measurement: Grab samples shall be taken (3) times per week and analyzed ------------------- for each specification.
This Product shall be delivered by pipeline to --------------------------- Xxxxx and risk of loss shall pass at the battery limits of HCU 942.
Quantity measurements shall be taken at HCU 942 meter -------------------- FQ-2600.
Xxxxx Hydrocracker Purge Hydrogen shall be delivered by pipeline and title to, and risk of loss for, such hydrogen shall pass to the Xxxxx Company at the battery limit of HCU 942.
Lack of duplicate pressure transmitters on D-1290 Fractionator Feed Flash Drum (stripper bottoms) at HCU 942 increases the likelihood of erroneous pressure indication due to instrument failure.
Total Crude Oil Volume / ( Heavy Gas Oil from AVU 146 to HCU 942 * 19.96 + Heavy Gas Oil from DCU 843 to HCU 942 * 20.02 + Light Cycle Oil to HCU 942 * 14.66 ) Heavy Gas Oil from AVU 146 to HCU 942 = Heavy Gas Oil from AVU 146 & Light Cycle Oil to HCU 942 - Light Cycle Oil to HCU 942 The above equations are based on the following deemed quantities.
Total Crude Oil Volume / ( Heavy Gas Oil from AVU 146 to HCU 942 * 21.64 + Heavy Gas Oil from DCU 843 to HCU 942 * 22.16 + Light Cycle Oil to HCU 942 * 65.67 ) Heavy Gas Oil from AVU 146 to HCU 942 = Heavy Gas Oil from AVU 146 & Light Cycle Oil to HCU 942 - Light Cycle Oil to HCU 942 EXHIBIT A-22 The above equations are based on the following deemed quantities.
Product Purchase Agreement Page 35 August 3, 1999 EXHIBIT A-23 Product: Diesel from HCU 942 ------- Target Specification: -------------------- Property Specification Test Method -------- ------------- ----------- API Gravity 30.0 Minimum ASTM D-1298, ASTM D-287, or ASTM D-4052 Corrosion 3 hrs.
Process upset due to erroneous level indication in D-1250 Cold LP Separator OH KO Drum at HCU 942 caused by plugging of a nozzle.
The following meters shall be used as input to the above calculations: Light Cycle Oil to HCU 942: XX-XXXX Heavy Gas Oil from DCU 843 to HCU 942: DCU 843 FE-1000 Heavy Gas Oil from AVU 146 & Light Cycle Oil to HCU 942: HCU 942 FQ-1020 Quality Measurement: Grab samples shall be taken at least (1) time per day and ------------------- analyzed by xxxxxxx and at least (3) times per week and analyzed by gas chromatography, and Xxxxxxx vapor pressure.