Unobstructed Sample Clauses

Unobstructed. Where a forward reach is unobstructed, the high forward reach shall be 48 inches (1220 mm) maximum and the low forward reach shall be 15 inches (380 mm) minimum above the finish floor or ground. Applicable 2010 ADA Accessibility Standards3
AutoNDA by SimpleDocs
Unobstructed. W here a clear floor space complying with Section 305 allows a parallel approach to an element and the edge of the clear floor space is 10 inches (255 mm) maximum from the element, the high side reach shall be 48 inches (1220 mm) maximum and the low side reach shall be 15 inches (380 mm) minimum above the floor. o See Figure 3 for required compliance  Office: reset thermostat and alarm panel to a height of 48” or less o ADA [2010] 309.3 Height. Operable parts shall be placed within one or more of the reach ranges specified in 308.
Unobstructed. Where a clear floor space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side reach shall be 15 inches (380 mm) minimum above the floor.  See Fair Housing Design Manual Chapter 2  See Figure 3  Men’s Restroom: o rearrange stall walls to create proper width and clear floor maneuvering space
Unobstructed access to all exits, fire extinguishers, electrical panels, emergency showers, and eyewash stations must be maintained at all times.
Unobstructed. Where a clear floor space complying with Section 305 allows a parallel approach to an element and the edge of the clear floor space is 10 inches (255 mm) maximum from the element, the high side reach shall be 48 inches (1220 mm) maximum and the low side reach shall be 15 inches (380 mm) minimum above the floor. o See Figure 3 for required complianceCommon Area Restroom: replace sink with ADA compliant sink (use compliant faucets) and wrap pipes
Unobstructed. Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side reach shall be 15 inches (380 mm) minimum above the finish floor or ground. o See Figure 3 for required compliancePool Area: grind or repour concrete surrounding gates to level slope on both sides of gate and ensure proper ADA maneuvering clearances o ANSI A117.1 [2003] 303.4 Ramps. Changes in level greater than 1/2 inch (13 mm) in height shall be ramped and shall comply with Section 405 or 406. o See Figure 1 for required compliance  Parking Area & Access Aisle: install asphalt pad or level out all ADA parking spaces and access aisles to 2% grade or less
Unobstructed. If the clear floor space allows a parallel approach by a person in a wheelchair, the high side reach permitted shall be 54 in (1370 mm) maximum and the low side reach shall be 1 S in (380 mm) minimum above the floor. See Fig. B4.2.6.1.  See Figure 3 for required compliance  Near Unit #218: o Install curb ramps at crosswalk along the accessible route
AutoNDA by SimpleDocs
Unobstructed. Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side reach shall be 15 inches (380 mm) minimum above the finish floor or ground.  See Figure 3  Men’s Restroom: o Remove and replace grab bars to meet ADA requirements.
Unobstructed. Where a clear floor space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side reach shall be 15 inches (380 mm) minimum above the floor. See Figure 3Community Room: o remove and reinstall drinking fountains to meet ADA height and knee space requirements  ADA [1991] 4.4.1* General. Objects projecting from walls (for example, telephones) with their leading edges between 27 in and 80 in (685 mm and 2030 mm) above the finished floor shall protrude no more than 4 in (100 mm) into walks, halls, corridors, passageways, or aisles (see Fig. 8(a)). Objects mounted with their leading edges at or below 27 in (685 mm) above the finished floor may protrude any amount (see Fig. 8(a) and (b)). Free-standing objects mounted on posts or pylons may overhang 12 in (305 mm) maximum from 27 in to 80 in (685 mm to 2030 mm) above the ground or finished floor (see Fig. 8(c) and (d)). Protruding objects shall not reduce the clear width of an accessible route or maneuvering space (see Fig. 8(e)).
Unobstructed. Where a clear floor space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48 inches (1220 mm) maximum and the low side reach shall be 15 inches (380 mm) minimum above the floor. o See Figure 3 for required compliance  Clubhouse Kitchen: install correct sink and proper ADA protections and ensure the knee space is compliant
Time is Money Join Law Insider Premium to draft better contracts faster.