TEC Assessment Sample Clauses

TEC Assessment. Calculate the base energy consumption by multiplying the measured power consumption as specified in this test procedure by the hours per day values in the equations below. If the EUT does not include the capability for Auto Power Down, then use the first equation (a). If the product does include Auto Power Down capability, and it meets the requirements in Annex A (A.3; A.4), then use the second equation (b). POn, PStandby and PAPD are power levels in ▇▇▇▇▇ as measured according to the measurement procedure set out in this Annex C. (a) Annual energy (kWh/yr) for a product with no Auto Power Down kWhBase = 0.365 x (TOn x POn + TStandby x P Standby ) (b) Annual energy (kWh/yr) for a product with Auto Power Down capability kWhBase = 0.365 x (TOn x POn + TStandby.x PStandby . + TAPD x PAPD) Example A: The EUT does not have Auto Power Down capability, and the measurements during the measurement procedure are as follows: POn = 24.0 ▇▇▇▇▇ and PStandby = 15.0 ▇▇▇▇▇. Using equation (a), the total energy consumption is then assessed to be: kWhBase = 0.365 * ( 9 * 24.0 + 15 * 15.0) = 161 kWh/year Example B: The EUT does have Auto Power Down capability, and the measurements during the measurement procedure are similar to example A: POn = 24.0 ▇▇▇▇▇, PStandby = 15.0 ▇▇▇▇▇ and PAPD = 3 ▇▇▇▇▇. Using equation (b), the total energy consumption is then assessed to be: kWhBase = 0.365 * ( 4.5 * 24.0 + 15 * 15.0 + 4.5 * 3.0) = 126.5 kWh/year If the annual TEC assessed for the product is less than the annual Energy Allowance calculated from Annex D below, then the product is compliant with the energy consumption targets of this Voluntary Agreement. ANNEX D – Maximum Energy Consumption Targets and Time Schedule
TEC Assessment. Calculate the base energy consumption by multiplying the measured power consumption as specified in this test procedure by the hours per day values in the equations below. If the EUT does not include the capability for Auto Power Down, then use the first equation (a). If the product does include Auto Power Down capability, and it meets the requirements in Annex A (A.3; A.4), then use the second equation (b). POn, PStandby and PAPD are power levels in ▇▇▇▇▇ as measured according to the measurement procedure set out in this Annex C. (a) Annual energy (kWh/yr) for a product with no Auto Power Down kWhBase = 0.365 x (TOn x POn + TStandby x P Standby ) (b) Annual energy (kWh/yr) for a product with Auto Power Down capability kWhBase = 0.365 x (TOn x POn + TStandby.x PStandby . + TAPD x PAPD) kWhBase = 0.365 * ( 9 * 24.0 + 15 * 15.0) = 161 kWh/year kWhBase = 0.365 * ( 4.5 * 24.0 + 15 * 15.0 + 4.5 * 3.0) = 126.5 kWh/year If the annual TEC assessed for the product is less than the annual Energy Allowance calculated from Annex D below, then the product is compliant with the energy consumption targets of this Voluntary Agreement. ANNEX D – MAXIMUM ENERGY CONSUMPTION TARGETS AND TIME SCHEDULE
TEC Assessment. Calculate the base energy consumption by multiplying the measured power consumption as specified in this test procedure by the hours per day values in the equation below. POn, ▇▇▇▇▇▇▇▇ and PAPD are power levels in ▇▇▇▇▇ as measured according to the measurement procedure set out in this Annex E. Annual energy (kWh/yr.) for a product with Auto Power Down capability kWhBase = 0.365 x (TOn x POn + TStandby.x PStandby. + TAPD x PAPD) Example: The EUT measurement procedure shows POn = 24.0 ▇▇▇▇▇, PStandby = 15.0 ▇▇▇▇▇ and PAPD = 3 ▇▇▇▇▇. Using the equation, the total energy consumption is then assessed to be: kWhBase = 0.365 * (4.5 * 24.0 + 15 * 15.0 + 4.5 * 3.0) = 126.5 kWh/year If the annual TEC assessed for the product is less than the annual Energy Limit calculated from Annex ED, then the product is compliant with the energy consumption targets of this Voluntary Agreement.