SUSA Table. SUSA (Sub-system Under Safety Analysis) table is typically used during safety analysis activity. The aim of a SUSA table is to highlight and to list the components/systems involved in the item under safety analysis, that is, everything inside the boundary, with inclusion of the interfaces. In general, each element of the list has not only to be identified in terms of name/description/etc., but it has to be classified in terms of development category as following: 01. 001 Electric Vehicle Controller Interlock Disconnecting high voltage supply Involved 01. 002 Power Electronic Interlock Disconnecting high voltage supply Interface 01.003 Motor Interlock Disconnecting high voltage supply Interface 01.004 Battery Interlock Disconnecting high voltage supply Interface 01.005 HVJB Interlock Disconnecting high voltage supply Involved 01. 006 Driving Mode Selector Driving mode selection Selecting the driving mode Involved 01. 007 Brake Pedal Driving mode selection Selecting the driving mode Involved 01.008 Accelerator sensor Driving mode selection Selecting the driving mode Interface 01.009 CAN CAN network Involved