Common use of Record S Clause in Contracts

Record S. No., make and year of manufacturing of Power transformer 3 Major Materials dispatched without inspection 4 Construction as per Approved Drawing 5 Civil works FQP documentation maintained during construction 6 Equipment (name it) provided in the BOQ/ drawing but not installed 7 Verification of pre-commissioning and commissioning testes of substation equipment i.e. Circuit Breaker, CT, PT, transformer, Charger, Battery, Relays, Control Panels, Switchgear, 11 KV cable etc 8 Present condition of main equipment 9 Functional Status of Transformer: WTI, OTI etc, Relays, Battery Charger, Battery, CB, CT, PT, Energy Meter, Control & Relay panel 10 Transformer oil tested 11 Transformer Relays, CT, PT , CB , Switchgears, battery sets, etc charged after test 12 Equipment charged after commissioning test 13 Gravel size proper 14 Earthing of main equipment, fence etc done properly 15 Sub Station fencing provided 16 Cable trench made with cable trays – or cables lying on trench floor 17 Whether Cable trenches have suitable slope to ensure automatic draining of rainwater 18 Proper storage of equipment 19 Cables tied on cable trays 20 Glands, lugs used (wherever need - at cable entries)

Appears in 8 contracts

Samples: www.wbsedcl.in, tneb.tnebnet.org, www.wbsedcl.in

AutoNDA by SimpleDocs

Record S. No., make and year of manufacturing of Power transformer 3 Major Materials dispatched without inspection 4 Construction as per Approved Drawing 5 Civil works FQP during construction documentation maintained during construction 6 Equipment (name it) provided in the BOQ/ drawing but not installed 7 Verification of pre-commissioning and commissioning testes of substation equipment i.e. Circuit Breaker, CT, PT, transformer, Charger, Battery, Relays, Control Panels, Switchgear, 11 KV cable etc 8 Present condition of main equipment 9 Functional Status of Transformer: WTI, OTI etc, Relays, Battery Charger, Battery, CB, CT, PT, Energy Meter, Control & Relay panel 10 Transformer oil tested 11 Transformer Relays, CT, PT , CB , Switchgears, battery sets, etc charged after test 12 Equipment charged after commissioning test 13 Gravel size proper 14 Earthing of main equipment, fence etc done properly 15 Sub Station fencing provided 16 Cable trench made with cable trays – or cables lying on trench floor 17 Whether Cable trenches have suitable slope to ensure automatic draining of rainwater 18 Proper storage of equipment 19 Cables tied on cable trays 20 Glands, lugs used (wherever need - at cable entries)

Appears in 7 contracts

Samples: dhbvn.org.in, dhbvn.org.in, dhbvn.org.in

AutoNDA by SimpleDocs

Record S. No., make and year of manufacturing of Power transformer 3 Major Materials dispatched without inspection 4 Construction as per Approved Drawing 5 Civil works FQP documentation maintained during construction 6 Equipment (( name it) provided in the BOQ/ drawing but not installed 7 Verification of pre-commissioning and commissioning testes of substation equipment i.e. Circuit Breaker, CT, PT, transformer, Charger, Battery, Relays, Control Panels, Switchgear, 11 KV cable etc 8 Present condition of main equipment 9 Functional Status of Transformer: WTI, OTI etc, Relays, Battery Charger, Battery, CB, CT, PT, Energy Meter, Control & Relay panel 10 Transformer oil tested 11 Transformer Relays, CT, PT , CB , Switchgears, battery sets, etc charged after test 12 Equipment charged after commissioning test 13 Gravel size proper 14 Earthing of main equipment, fence etc done properly 15 Sub Station fencing provided 16 Cable trench made with cable trays – or cables lying on trench floor 17 Whether Cable trenches have suitable slope to ensure automatic draining of rainwater 18 Proper storage of equipment 19 Cables tied on cable trays 20 Glands, lugs used (wherever need - at cable entries)

Appears in 1 contract

Samples: dhbvn.org.in