Pressure Sample Clauses

Pressure. The System user is not entitled to deliver natural gas to Gas Connect Austria at the Entry Point Überackern Sudal at a pressure of below 64 bar. Entry Point Überackern 7-fields Normal cubic meter (Nm³) Normal cubic meter (Nm³) is a cubic meter of natural gas at 273.15 K (= 0°C) and 101,325 kPa (=1.01325 bara). Quality specifications The natural gas delivered by the System User at the Entry Point Überackern 7-fields for transportation must be in line with the following chemical and physical specifications:
AutoNDA by SimpleDocs
Pressure. Seller shall deliver gas at the Point(s) of Delivery at a pressure sufficient to effect delivery into the receiving Transporter(s)' facilities.
Pressure. For purposes of measurement and meter calibration, the atmospheric pressure for each of the Receipt Points and Delivery Points shall be assumed to be the pressure value determined by Gatherer, or its designee, for the county elevation in which such point is located pursuant to generally accepted industry practices irrespective of the actual atmospheric pressure at such points from time to time. For the purposes herein, such atmospheric pressure will be assumed to be 14.65 pounds per square inch absolute.
Pressure. 10.1 The quantities of gas delivered or caused to be delivered by Shipper to Transporter hereunder shall be delivered into Transporter's pipeline system at a pressure sufficient to enter Transporter's system, but in no event shall such gas be delivered at a pressure exceeding the maximum authorized operating pressure or such other pressure as Transporter permits at the Point(s) of Receipt.
Pressure. High precision pressure gauges (accurate to ± 1%) shall be fitted to the condenser and evaporator and to the compressor inlet when the evaporator is fitted with a pressure regulator.
Pressure. 7.1 Shipper shall deliver the Natural Gas at the Delivery Point at a Pressure not
Pressure. Customer shall Tender or cause to be Tendered Customer Gas and Customer Injected NGLs to each applicable Receipt Point at sufficient pressure to enter the TGP System against its contractual operating pressure, but not in excess of the maximum operating pressure for such Receipt Point. Provider shall redeliver Customer Residue Gas and Customer NGLs at each applicable Delivery Point at pressures not in excess of the maximum operating pressure for such Delivery Point.
AutoNDA by SimpleDocs
Pressure. Shipper shall Tender or cause to be Tendered Gas and Joint Dedicated Liquid Condensate to each applicable Receipt Point at sufficient pressure to enter the Gathering System against its operating pressure, but not in excess of the maximum operating pressure set forth in the design documents for the applicable Facility Segment contained in the applicable, approved Gathering System Plan (which such maximum operating pressure shall be sufficient to permit such Gas and Joint Dedicated Liquid Condensate to enter the Gathering System and the facilities of the Processing Plants, Downstream Pipelines or Downstream Condensate Storage Tanks (as applicable) but not higher than the MAOP of the Downstream Pipelines or other facilities). Shipper shall have the obligation to ensure that Gas and Joint Dedicated Liquid Condensate is prevented from entering the Gathering System at pressures in excess of such maximum operating pressure, and Gatherer shall have the right to restrict or relieve the flow of Gas and Joint Dedicated Liquid Condensate into the Gathering System to protect the Gathering System from over pressuring. Gatherer shall not change such maximum operating pressures without prior written notification to Shipper. Gatherer shall install, own, operate and maintain compression facilities sufficient to deliver Shipper’s owned and Controlled Gas and Joint Dedicated Liquid Condensate into the applicable Delivery Points. Re-deliveries of Gas and Joint Dedicated Liquid Condensate by Gatherer to or for the account of Shipper at the applicable Delivery Points shall be at such pressures as may exist from time to time in the Gathering System at the applicable Delivery Point. Gatherer’s obligation to re-deliver Gas and Joint Dedicated Liquid Condensate to a given Delivery Point shall be subject to the operational limitations of the Processing Plant or Downstream Pipelines (as applicable) receiving such Gas or Joint Dedicated Liquid Condensate (as applicable), including the Processing Plant’s or Downstream Pipeline’s capacity, Gas measurement capability, operating pressures and any operational balancing agreements as may be applicable.
Pressure. The gas delivered by Customer at the Receipt Point(s) shall be delivered at a pressure sufficient to overcome the operating pressure existing in Company's or its Transporter's facility from time to time; however, in no event shall such delivery pressure exceed the maximum operating pressure of the system receiving the gas. The gas delivered at the Delivery Point(s) shall be delivered by Company's Transporter at the pressure existing from time- to-time in Company's or Transporter's pipeline. Company's Transporter shall not be obligated to install or operate compression facilities in order to effect receipt or delivery of gas. Customer (or Customer's designee), any transporter and Company's Transporter are completely and solely responsible for the installation and maintenance of overpressure protection equipment on their own pipeline(s), valve(s) and any other interconnection equipment.
Pressure. 9.1. The User shall hand over natural gas for transportation at hand-over points with a pressure not exceeding the maximum pressure and not lower than the minimum, as published on the Operator’s website.