Common use of Pressure Clause in Contracts

Pressure. Shipper shall Tender or cause to be Tendered Gas and Joint Dedicated Liquid Condensate to each applicable Receipt Point at sufficient pressure to enter the Gathering System against its operating pressure, but not in excess of the maximum operating pressure set forth in the design documents for the applicable Facility Segment contained in the applicable, approved Gathering System Plan (which such maximum operating pressure shall be sufficient to permit such Gas and Joint Dedicated Liquid Condensate to enter the Gathering System and the facilities of the Processing Plants, Downstream Pipelines or Downstream Condensate Storage Tanks (as applicable) but not higher than the MAOP of the Downstream Pipelines or other facilities). Shipper shall have the obligation to ensure that Gas and Joint Dedicated Liquid Condensate is prevented from entering the Gathering System at pressures in excess of such maximum operating pressure, and Gatherer shall have the right to restrict or relieve the flow of Gas and Joint Dedicated Liquid Condensate into the Gathering System to protect the Gathering System from over pressuring. Gatherer shall not change such maximum operating pressures without prior written notification to Shipper. Gatherer shall install, own, operate and maintain compression facilities sufficient to deliver Shipper’s owned and Controlled Gas and Joint Dedicated Liquid Condensate into the applicable Delivery Points. Re-deliveries of Gas and Joint Dedicated Liquid Condensate by Gatherer to or for the account of Shipper at the applicable Delivery Points shall be at such pressures as may exist from time to time in the Gathering System at the applicable Delivery Point. Gatherer’s obligation to re-deliver Gas and Joint Dedicated Liquid Condensate to a given Delivery Point shall be subject to the operational limitations of the Processing Plant or Downstream Pipelines (as applicable) receiving such Gas or Joint Dedicated Liquid Condensate (as applicable), including the Processing Plant’s or Downstream Pipeline’s capacity, Gas measurement capability, operating pressures and any operational balancing agreements as may be applicable.

Appears in 4 contracts

Sources: Gathering Agreement (CONE Midstream Partners LP), Gathering Agreement (CONE Midstream Partners LP), Gathering Agreement (CONE Midstream Partners LP)

Pressure. Shipper shall Tender or cause to be Tendered Gas and Joint Priority One Dedicated Liquid Condensate to each applicable Receipt Point at sufficient pressure to enter the Gathering System against its operating pressure, but not in excess of the maximum operating pressure set forth in the design documents for the applicable Facility Segment contained in the applicable, approved Gathering System Plan (which such maximum operating pressure shall be sufficient to permit such Gas and Joint Priority One Dedicated Liquid Condensate to enter the Gathering System and the facilities of the Processing Plants, Downstream Pipelines or Downstream Condensate Storage Tanks (as applicable) but not higher than the MAOP of the Downstream Pipelines or other facilities). Shipper shall have the obligation to ensure that Gas and Joint Priority One Dedicated Liquid Condensate is prevented from entering the Gathering System at pressures in excess of such maximum operating pressure, and Gatherer shall have the right to restrict or relieve the flow of Gas and Joint Priority One Dedicated Liquid Condensate into the Gathering System to protect the Gathering System from over pressuring. Gatherer shall not change such maximum operating pressures without prior written notification to Shipper. Gatherer shall install, own, operate and maintain compression facilities sufficient to deliver Shipper’s owned and Controlled Gas and Joint Priority One Dedicated Liquid Condensate into the applicable Delivery Points. Re-deliveries of Gas and Joint Priority One Dedicated Liquid Condensate by Gatherer to or for the account of Shipper at the applicable Delivery Points shall be at such pressures as may exist from time to time in the Gathering System at the applicable Delivery Point. Gatherer’s obligation to re-deliver Gas and Joint Priority One Dedicated Liquid Condensate to a given Delivery Point shall be subject to the operational limitations of the Processing Plant or Downstream Pipelines (as applicable) receiving such Gas or Joint Priority One Dedicated Liquid Condensate (as applicable), including the Processing Plant’s or Downstream Pipeline’s capacity, Gas measurement capability, operating pressures and any operational balancing agreements as may be applicable.

Appears in 2 contracts

Sources: Gathering Agreement (CONE Midstream Partners LP), Gathering Agreement (CONE Midstream Partners LP)

Pressure. Shipper shall Tender or cause to be Tendered Shipper Gas and Joint Dedicated Liquid Condensate and/or Shipper Injected Liquids, as applicable, to each applicable Receipt Point at sufficient pressure to enter the Gathering System against its contractual operating pressure, but not in excess of the maximum operating pressure set forth for such Receipt Point. Gatherer shall redeliver Shipper Gas (including any Drip Liquids allocated to Shipper in accordance with this Agreement) and/or Shipper Injected Liquids at each applicable Delivery Point at pressures not in excess of the design documents for the applicable Facility Segment contained in the applicable, approved Gathering System Plan (which such maximum operating pressure shall be sufficient to permit for such Gas and Joint Dedicated Liquid Condensate to enter the Gathering System and the facilities of the Processing Plants, Downstream Pipelines or Downstream Condensate Storage Tanks Delivery Point. (as applicablea) but not higher than the MAOP of the Downstream Pipelines or other facilities). Shipper shall have the obligation means to ensure that Shipper Gas and Joint Dedicated Liquid Condensate is Shipper Injected Liquids are prevented from entering the Gathering System at pressures in excess of such the applicable maximum operating pressure, and Gatherer shall have the obligation and right to restrict or relieve the flow of Gas and Joint Dedicated Liquid Condensate Injected Liquids into the Gathering System to protect the Gathering System from over pressuring. Gatherer shall not change such maximum operating pressures without prior written notification to Shipper. Gatherer shall install, own, operate and maintain compression facilities sufficient to deliver Shipper’s owned and Controlled Gas and Joint Dedicated Liquid Condensate into the applicable Delivery Points. Re-deliveries of Gas and Joint Dedicated Liquid Condensate by Gatherer to or for the account of Shipper at the applicable Delivery Points shall be at such pressures as may exist from time to time in the Gathering System at the applicable Delivery Point. . (b) Gatherer’s obligation to re-deliver redeliver Gas and Joint Dedicated Liquid Condensate (including any Drip Liquids allocated to Shipper in accordance with this Agreement) and/or Injected Liquids, as applicable, to a given Delivery Point shall shall, subject to Gatherer’s compliance with Section 8.7, be subject to the operational limitations of the Processing Plant or Downstream Pipelines (as applicable) Facility receiving such Gas (or Joint Dedicated Liquid Condensate (as applicable)Drip Liquids) or Injected Liquids, including the Processing Plant’s or Downstream PipelineFacility’s capacity, Gas measurement capability, operating pressures and any operational balancing agreements as may be applicable. TERMS IN THIS EXHIBIT HAVE BEEN REDACTED BECAUSE CONFIDENTIAL TREATMENT FOR THOSE TERMS HAS BEEN REQUESTED. THE REDACTED MATERIAL HAS BEEN FILED SEPARATELY WITH THE SECURITIES AND EXCHANGE COMMISSION, AND THE TERMS HAVE BEEN MARKED AT THE APPROPRIATE PLACE WITH TWO ASTERISKS (**).

Appears in 2 contracts

Sources: Gas Gathering Agreement (Hess Midstream Partners LP), Gas Gathering Agreement (Hess Midstream Partners LP)

Pressure. Shipper Section 3.1 Producer shall Tender deliver, or cause to be Tendered delivered, to Gatherer at the Points of Receipt, the Gas to be gathered hereunder at the pressures existing in the System as such pressure may exist from time to time, not to exceed the Maximum Pipeline Pressure and, if applicable, the Maximum CRP Pressure. Producer shall install, operate and Joint Dedicated Liquid Condensate maintain, at its sole expense, such pressure regulating devices as may be necessary to each applicable Receipt Point at sufficient regulate the pressure of Gas prior to enter deliver to Gatherer so as not to exceed the Gathering System against its operating Maximum Pipeline Pressure and, if applicable, the Maximum CRP Pressure. If Producer fails to regulate such pressure, but then the Gatherer may shut in such Gas until Producer has installed such regulating device. Section 3.2 Gatherer will deliver Gas at the Points of Delivery at the pressures required by the receiving pipeline at each such point, not in excess of to exceed the maximum allowable operating pressure set forth of TET, DTI, or TCO. If necessary, Gatherer shall provide sufficient compression to attempt to insure that the pressures existing on the System do not exceed the Maximum Pipeline Pressure and, if applicable, the Maximum CRP Pressure. Section 3.3 If Producer’s delivery of Gas volumes are restricted by Gatherer’s operating pressures exceeding the Maximum Pipeline Pressure or, if operating pressure should exceed if applicable, the Maximum CRP Pressure for thirty (30) Days in the design documents for the applicable Facility Segment contained in the applicableaggregate during any consecutive three-month period at a Point of Receipt, approved Gathering System Plan (which such maximum operating pressure shall be sufficient to permit such Gas and Joint Dedicated Liquid Condensate to enter the Gathering System and the facilities excluding events of the Processing PlantsForce Majeure, Downstream Pipelines or Downstream Condensate Storage Tanks (as applicable) but not higher than the MAOP of the Downstream Pipelines or other facilities). Shipper shall have the obligation to ensure that Gas and Joint Dedicated Liquid Condensate is prevented from entering the Gathering System at pressures in excess of such maximum operating pressure, and Gatherer Producer shall have the right to restrict or relieve notify Gatherer in writing of such occurrence (“Pressure Notice”) within ninety (90) Days of such occurrence. Upon receipt of Producer’s Pressure Notice, Gatherer will proceed to promptly address any operational issues to again provide Producer with pressures not to exceed the flow of Gas and Joint Dedicated Liquid Condensate into Maximum Pipeline Pressure and, if applicable, the Gathering System to protect the Gathering System from over pressuringMaximum CRP Pressure. Gatherer shall not change such maximum operating pressures without prior written notification to Shipper. Gatherer shall install, own, operate and maintain compression facilities sufficient to deliver Shipper’s owned and Controlled Gas and Joint Dedicated Liquid Condensate into the applicable Delivery Points. Re-deliveries of Gas and Joint Dedicated Liquid Condensate by Gatherer to or for the account of Shipper at the applicable Delivery Points shall be at such pressures as may exist from time to time in the Gathering System at the applicable Delivery Point. Gatherer’s This obligation to re-deliver Gas and Joint Dedicated Liquid Condensate to a given Delivery Point shall be subject to the operational limitations provisions of Section 4.1 of this Agreement. Section 3.4 If Gatherer’s only curative measure to maintain the Processing Plant Maximum Pipeline Pressure or Downstream Pipelines the Maximum CRP Pressure requires Gatherer to install additional compression and/or install additional pipelines, Gatherer may provide Producer written notice, within the twenty (20) Day period following Producer’s Pressure Notice, of Gatherer’s good faith intention to install such additional compression or pipelines and the target In-Service Date, which will be no later than twelve (12) months from the Pressure Notice, for such additional facilities, unless caused by Excusable Delay. Gatherer shall proceed without unreasonable delay and will install such facilities as applicable) receiving such Gas or Joint Dedicated Liquid Condensate (expeditiously as applicable), including reasonably possible. This obligation shall be subject to the Processing Plant’s or Downstream Pipeline’s capacity, Gas measurement capability, operating pressures and any operational balancing agreements as may be applicableprovisions of Section 4.1 of this Agreement.

Appears in 2 contracts

Sources: Gas Gathering Agreement, Gas Gathering Agreement (Vantage Energy Inc.)