Common use of OVERSIZE Clause in Contracts

OVERSIZE. (1) If the City requires a sanitary sewer either within or external to the Development Area to be larger than necessary to serve the Development Area: (a) all such Oversize sanitary sewer lines shall be designated at the time the Construction Drawings are given final approval by the Senior Infrastructure Engineer; (b) the City shall pay, from the Developer Funded Infrastructure Stabilization Fund - Utility Oversize to the Developer of Record the additional cost of such larger size pipe and accessories as approved by and in the sole discretion of the Managing Director, Calgary Approvals Coordination, at prices in accordance with the Unit Rate Schedule; and (c) the City shall not make any payments from the Developer Funded Infrastructure Stabilization Fund - Utility Oversize unless: (i) the line is established as Oversize in the Construction Drawings approved by the Senior Infrastructure Engineer prior to the signing of the Special Clauses Agreement; and (ii) the internal diameter of the sanitary sewer pipe exceeds three hundred millimetres (300 mm). (a) In areas where the sanitary sewer mains are located deeper than six (6) metres, a dual sewer system may be required and the Developer of Record will be entitled to an Oversize recovery for all mains installed at a depth of six (6) metres or more to crown of pipe; (b) The dual sewer system requirement shall be determined as early as possible in the approval process; and (c) The City shall pay, from the Developer Funded Infrastructure Stabilization Fund - Utility Oversize to the Developer of Record the additional cost of the oversized portion of the mains that are located deeper than six (6) metres underground as approved by the Managing Director, Calgary Approvals Coordination, at prices in accordance with the Unit Rate Schedule.

Appears in 3 contracts

Sources: Master Development Agreement, Master Development Agreement, Master Development Agreement

OVERSIZE. (1) If the City requires a sanitary sewer either within or external to the Development Area to be larger than necessary to serve the Development Area: (a) all such Oversize sanitary sewer lines shall be designated at the time the Construction Drawings are given final approval by the Senior Infrastructure EngineerCoordinator, Development Servicing; (b) the City shall pay, from the Developer Funded Infrastructure Stabilization Fund - Utility Oversize to the Developer of Record the additional cost of such larger size pipe and accessories as approved by and in the sole discretion of the Managing DirectorManager, Calgary Approvals CoordinationGrowth Management, at prices in accordance with the Unit Rate Schedule; and (c) the City shall not make any payments from the Developer Funded Infrastructure Stabilization Fund - Utility Oversize unless: (i) the line is established as Oversize in the Construction Drawings approved by the Senior Infrastructure Engineer Coordinator, Development Servicing prior to the signing of the Special Clauses Agreement; and (ii) the internal diameter of the sanitary sewer pipe exceeds three hundred millimetres (300 mm). (a) In areas where the sanitary sewer mains are located deeper than six (6) metres, a dual sewer system may be required and the Developer of Record will be entitled to an Oversize recovery for all mains installed at a depth of six (6) metres or more to crown of pipe; (b) The dual sewer system requirement shall be determined as early as possible in the approval process; and (c) The City shall pay, from the Developer Funded Infrastructure Stabilization Fund - Utility Oversize to the Developer of Record the additional cost of the oversized portion of the mains that are located deeper than six (6) metres underground as approved by the Managing DirectorManager, Calgary Approvals CoordinationGrowth Management, at prices in accordance with the Unit Rate Schedule.

Appears in 1 contract

Sources: Master Development Agreement