Main Structural System Design. 2.1.2.1. Steel Structural Systems • Scaled plans (1/8” preferred) indicating layout of floor slabs, column lines piece type & sizes, moment connections and bracing locations. Slab elevations noted. • Column criteria, preferably, a schedule with base & leveling plates. • Bracing elevations with members sized. • Girder & truss elevations with members sized. • Criteria for curtain wall wind bracing loads and criteria for skylight Supports, • Tie-rod & cable requirements. • Typical connection details. • Typical special connection detail (i.e., pipe conditions) • Typical exterior wall sections / details. • Typical framing @ floor & roof openings with quantity allowance. • Typical beam opening details with quantity allowances. • Allowances for slab depressions, equipment support, roof screen support, window washing anchorage, satellite dish support, etc. • Slab locations, thickness and deck type / size. • Type of deck closure relative to light gauge or bent plate material. • Number of deck shear connectors noted. • Spray fireproofing or concrete encasement criteria. • Priming / painting criteria. 2.1.2.2. Cast-in Place Concrete Systems • Scaled plans (1/8” preferred) indicating layout of floor slabs, openings, column lines, slab type & sizes and structural wall locations. Slab elevations noted. • Column criteria, preferably, a schedule with sizes and reinforcing requirements. • Structural wall, beams & column drop sections & details with reinforcing requirements. • Structural girder sections & details with reinforcing requirements. • Criteria for curtain wall wind bracing loads and criteria for skylight supports. • Typical exterior wall sections / details. • Typical reinforcing @ floor & roof openings with quantity allowance. • Typical beam opening reinforcing with quantity allowances. • Embed allowance requirements (i.e. Loading dock angles, sleeves, steel support plates, etc.) • Slab placement criteria. • Finishing & curing criteria. 2.1.2.3. Structural Precast Systems • Scaled plans (1/8” preferred) indicating layout of floor slabs, openings, column lines, slab type & sizes and structural wall locations. Slab elevations noted. • Column criteria, preferably, a schedule w/ sizes and reinforcing requirements. • Structural floor, wall, beam sections & details with reinforcing requirements. • Structural girder sections & details with reinforcing requirements. • Stair element system - if precast. • Criteria for curtain wall wind bracing loads and criteria for skylight supports, • Typical exterior wall sections / details. • Typical reinforcing @ floor & roof openings with quantity allowance. • Typical beam opening reinforcing with quantity allowances. • Embed allowance requirements (ie. Piece connections, loading dock angles, sleeves, steel support plates, etc.) • Topping slab placement criteria. • Finishing & curing criteria. • Caulking criteria 2.1.2.4. Wood / Light Gauge Framing Systems • Scaled plans (1/8” preferred) indicating layout of floor framing, openings, column lines and structural wall locations. Slab elevations noted. • Wood species, sizes and rating requirements required for all framing elements. • Metal stud and joist sizes and gauge. • Typical connection details. • Truss elevations. • Typical exterior wall sections / details.

Appears in 2 contracts

Sources: Master Design Professional Agreement, Master Design Professional Agreement