Load following Sample Clauses

The Load Following clause defines the obligation of a power supplier to adjust the amount of electricity delivered in real time to match the fluctuating demand of the buyer. In practice, this means the supplier must increase or decrease generation as the buyer's consumption rises or falls, ensuring a continuous balance between supply and demand. This clause is essential for maintaining grid stability and reliability, as it allocates responsibility for managing demand variability and helps prevent power shortages or surpluses.
Load following. (i) LEM will provide all of Big Rivers' Load Following requirements with respect to Member Power, without adjustment to the Power Value Amount for the applicable period, subject to the following conditions: (A) LEM shall not be obligated to provide Load Following services for Big Rivers, that, when combined with the provision of Base Power requirements (after adjustment for the SEPA Contract pursuant to Section 5.2), would exceed the Maximum Hourly Power Purchase Amount at any time; and (B) LEM shall not be obligated to provide Load Following services for loss of generation under the control of Big Rivers, or any third-party resource serving Big Rivers, other than from the Generating Plants; and POWER PURCHASE AGREEMENT BETWEEN BIG RIVERS ELECTRIC CORPORATION AND LG&E ENERGY MARKETING INC. (C) LEM shall not be obligated to provide Load Following services for any of Big Rivers' loads that are added to the Big Rivers' system after 1996, and that require Load Following services that are materially different than the aggregate of all loads that were served by Big Rivers as of December 31, 1996 exclusive of the Smelter Requirements. (ii) During the Term of this Agreement, LEM will provide all of Big Rivers' Load Following requirements, if any, with respect to Oglethorpe Power, Hoosier Power and HMP&L Power without adjustment to the Power Value Amount for the applicable period. (iii) Any additional amounts of Load Following required by Big Rivers for the load of its Members that it serves or any transmission customer serving load within Big Rivers' control area shall be supplied to Big Rivers by LEM with a corresponding adjustment to the Power Value Amount equivalent to the LEM rates for such Load Following Service, in accordance with in Section 6.2(f).
Load following. Seller shall use commercially reasonable efforts to cause the Facility to follow Buyer's load and any changes in Buyer's load, based upon the information or data provided to Seller by Buyer pursuant to this Agreement and consistent with Prudent Electric Industry Practice. Buyer shall be responsible for all costs associated with such efforts and shall be entitled to all of the revenues derived each Month from the Facility that would not have been obtained but for such efforts, to the extent that such revenues are not greater than losses or costs (including fuel costs and $1.00 per MWh for variable O&M) incurred with respect to such efforts in such Month and any net revenues in excess thereof shall be shared in accordance with Section 7.
Load following. Load following entails that players with major production changes report production plans with a resolution of 15 minutes. Load following with a quarter-hourly resolution improves the quality of the frequency of the synchronous system. Energinet. dk East Not used. Energinet. ▇▇ ▇▇▇▇ Production balance centres with variable production deliver running schedules with a resolution of 5 min. Partly, 5 min and 15 min. plans are sent to other TSOs Fingrid Hour shift regulation. Balance centres inform Fingrid about hours containing more than 100 MW of changes in their balance. Yes Statnett Players with major production changes make their production plans using a quarter-hourly resolution. ▇▇▇▇▇▇▇▇ can move planned production changes for all players by up to 15 minutes. Yes Yes Svenska Kraftnät Players with major production changes plan production plans with a quarter-hourly resolution and report the production plans with a quarter-hourly resolution to Svenska Kraftnät. Svenska Kraftnät has the right to move production by at least 15 minutes. Yes
Load following. Load following entails that players with major production changes report production plans with a resolution of 15 minutes. Load following with a quarter-hourly resolution improves the quality of the frequency of the synchronous system. This service can be exchanged between the subsystems. Energinet. dk East Not used. Energinet. ▇▇ ▇▇▇▇ Production balance centres with variable production deliver running schedules with a resolution of 5 min. Partly, 5 min and 15 min. plans are sent to other TSOs Fingrid Hour shift regulation. Balance centres inform Fingrid about hours containing more than 100 MW of changes in their balance. Yes¹ Statnett Players with major production changes make their production plans using a quarter-hourly resolution. Statnett can move planned production changes for all players by up to 15 minutes. Yes¹ Yes¹ Svenska Kraftnät Players report production plans with a quarter-hourly resolution to SvK. SvK has the right to move production by at least a quarter of an hour. Yes¹