LIS Forecasting Sample Clauses

The LIS Forecasting clause establishes the requirements and procedures for providing forecasts related to the Licensee Information System (LIS). Typically, this clause outlines how and when parties must share projected data or usage estimates, such as anticipated system loads or user numbers, to facilitate planning and resource allocation. By setting clear expectations for the exchange of forecast information, the clause helps ensure operational efficiency and minimizes the risk of resource shortages or over-provisioning.
LIS Forecasting. 7.2.2.8.1 Both CLEC and CenturyLink shall work in good faith to define a mutually agreed upon forecast of LIS trunking. 7.2.2.8.2 Both Parties shall participate in semi-annual joint planning meetings to establish trunk design and Provisioning requirements. The Parties agree to provide mutual trunk forecast information to ensure End User Customer call completion between the Parties' networks. Such forecasts shall be for LIS trunking that impacts the Switch capacity and facilities of each Party. CenturyLink shall provide CLEC trunk group specific projections to CLEC on or before the date of the joint planning meeting. 7.2.2.8.3 Switch capacity growth requiring the addition of new switching modules may require six (6) months for ordering and installation. To align with the timeframe needed to provide for the requested facilities, including engineering, ordering, installation and make ready activities, for capacity growth CenturyLink will utilize CLEC's semi-annual forecasts and near-term demand submitted on Unforecast Demand Notification Forms to ensure availability of Switch capacity. 7.2.2.8.4 The forecast will identify trunking requirements for a two (2) year period. 7.2.2.8.5 Both Parties will follow the forecasting and Provisioning requirements of this Agreement for the appropriate sizing of trunks, and use of direct End Office Switch versus Tandem Switch routing. See Section 7.2.2.1.3.
LIS Forecasting. 7.2.2.8.1 Both CLEC and Qwest shall work in good faith to define a mutually agreed upon forecast of LIS trunking. 7.2.2.8.2 Both Parties shall have the obligation to participate in joint planning meetings at semi annual intervals to establish trunk design and Provisioning requirements. The Parties agree to provide mutual trunk forecast information to ensure End User call completion between the Parties’ networks. Such forecasts shall be for LIS trunking which impacts the Switch capacity and facilities of each Party. Qwest shall provide trunk group specific projections to the CLEC on or before the date of the joint planning meeting. 7.2.2.8.3 Switch capacity growth requiring the addition of new switching modules may require six (6) months to order and install. To align with the timeframe needed to provide for the requested facilities, including engineering, ordering, installation and make ready activities, for capacity growth, Qwest will utilize CLEC forecasts and near-term demand submitted on Unforecast Demand Notification Forms to ensure availability of Switch capacity. 7.2.2.8.4 The forecast will identify trunking requirements for a two (2) year period. From the semi-annual close date as outlined in the forecast cycle, the receiving Party will have one (1) month to determine network needs and place vendor orders which may require a six (6) month interval to complete the network build. Seven (7) months after submission of the forecast, Qwest will have the necessary capacity in place to meet orders against the forecast. For ordering information see Section 7.4. See also Section 7.2.2.8.6. 7.2.2.8.5 Both Parties will follow the forecasting and Provisioning requirements of this Agreement for the appropriate sizing of trunks, and use of direct end office vs. tandem routing. See Section 7.2.2.1.3.
LIS Forecasting. 7.2.2.8.1 Both CLEC and Qwest shall work in good faith to define a mutually agreed upon forecast of LIS trunking. 7.2.2.8.2 Both Parties shall have the obligation to participate in joint Qwest Version 3.7 Template Agreement, 05-14-2001 Page 46 5-24-2001/bbd/Z-Tel/NE/CDS-010523-0107 planning meetings at quarterly intervals to establish trunk design and provisioning requirements. The Parties agree to provide mutual trunk forecast information t ensure end user call completion between the Parties’ networks. Such forecasts shall be for LIS trunking, which impacts the switch capacity and facilities of each Party. 7.2.2.8.3 Switch capacity growth requiring the addition of new switching modules may require six months to order and install. To align with the timeframe needed to provide for the requested facilities, including engineering, ordering, installation and make ready activities, the Parties will utilize Qwest standard forecast timelines, as defined in the standard Qwest LIS Trunk Forecast Forms for growth planning. For capacity growth, Qwest will utilize CLEC forecasts to ensure availability of switch capacity. 7.2.2.8.4 Each Party will utilize the Forecast cycle outlined on the Qwest LIS Trunk Forecast Forms, which stipulates that forecasts be submitted on a quarterly basis. The forecast will identify trunking requirements for a two (2) year period. From the quarterly close date as outlined in the forecast cycle, the receiving Party will have one month to determine network needs and place vendor orders which may require a six (6) month interval to complete the network build. Seven (7) months after submission of the initial forecast, Qwest will have the necessary capacity in place to meet the CLEC forecast. After the initial forecast, Qwest will ensure that capacity is available to meet CLECs’ needs. For ordering information see the Interconnection Section of this Agreement. 7.2.2.8.5 Both Parties will follow the forecasting and provisioning requirements of this Agreement for the appropriate sizing of trunks, and use of direct end office vs. tandem routing.
LIS Forecasting. 7.2.2.8.1 Both CLEC and Qwest shall work in good faith to define a mutually agreed upon forecast of LIS trunking. 7.2.2.8.2 Both Parties shall have the obligation to participate in joint planning meetings at semi annual intervals to establish trunk design and provisioning requirements. The Parties agree to provide mutual trunk forecast information to ensure end user call completion between the Parties’ networks. Such forecasts shall be for LIS trunking which impacts the switch capacity and facilities of each Party. Qwest shall provide trunk group specific projections to the CLEC on or before the date of the joint planning meeting. 7.2.2.8.3 Switch capacity growth requiring the addition of new switching modules may require six months to order and install. To align with the timeframe needed to provide for the requested facilities, including engineering, ordering, installation and make ready activities, Qwest will utilize CLEC semi-annual forecasts and near-term demand submitted on Unforecast Demand Notification Forms to ensure availability of switch capacity. 7.2.2.8.4 The forecast will identify trunking requirements for a two (2) year period. From the semi-annual close date as outlined in the forecast cycle, the receiving Party will have one (1) month to determine network needs and place vendor orders which may require a six (6) month interval to complete the network build. Each Party agrees to work in good faith and as promptly as possible to complete any needed network builds. Each Party may place trunk orders with respect to a forecast any time after submission of the forecast, in which case the other Party will provide capacity in response to such orders where spare capacity exists in its network at the time of that order. In any event, seven (7) months after submission of the forecast, Qwest will have the necessary capacity in place to meet orders against the forecast. For ordering information see Section 7.4. See also Section 7.2.2.8.6. 7.2.2.8.5 Both Parties will follow the forecasting and provisioning requirements of this Agreement for the appropriate sizing of trunks, and use of direct end office vs. tandem routing. See Section 7.2.2.1.3.
LIS Forecasting. 7.2.2.8.1 Both CLEC and Qwest shall work in good faith to define a mutually agreed upon forecast of LIS trunking. 7.2.2.8.2 Both Parties shall have the obligation to participate in joint planning meetings at semi-annual intervals to establish trunk design and Provisioning requirements. The Parties agree to provide mutual trunk forecast information to ensure End User call completion between the Parties’ networks. Such forecasts shall be for LIS trunking that impacts the Switch capacity and facilities of each Party. Qwest shall provide trunk group specific projections to CLEC on or before the date of the joint planning meeting. 7.2.2.8.3 Switch capacity growth requiring the addition of new switching modules may require six (6) months to order and install. To align with the timeframe needed to provide for the requested facilities, including engineering, ordering, installation and make ready activities, the Parties will utilize Qwest standard forecast timelines, as defined in the standard Qwest LIS Trunk Forecast Forms for growth planning. For capacity growth, Qwest will utilize CLEC semi- annual forecasts and near-term demand submitted on Unforecast Demand Notification Forms to ensure availability of Switch capacity.
LIS Forecasting. 7.2.2.8.1 Both CLEC and CenturyLink shall work in good faith to define a mutually agreed upon, but non-binding, forecast of LIS trunking. 7.2.2.8.2 Both Parties shall participate in semi-annual joint planning meetings to establish trunk design and Provisioning requirements, upon request of either Party. The Parties agree to provide mutual trunk forecast information to ensure End User customer call completion between the Parties' networks. Such forecasts shall be for LIS trunking that impacts the Switch capacity and facilities of each Party. CenturyLink shall provide CLEC trunk group specific projections to CLEC on or before the date of the joint planning meeting. 7.2.2.8.3 Switch capacity growth requiring the addition of new switching modules may require six (6) months for ordering and installation. To align with the timeframe needed to provide for the requested facilities, including engineering, ordering, installation and make ready activities, for capacity growth CenturyLink will utilize CLEC's semi-annual forecasts and near-term demand submitted on Unforecast Demand Notification Forms to ensure availability of Switch capacity. 7.2.2.8.4 The forecast will identify trunking requirements for a two (2) year period and are based on the information available to each Party at the time the forecasts are prepared. Unforecasted trunk demands, if any, by one Party will be accommodated by the other Party as soon as practicable based on facility availability. 7.2.2.8.5 Both Parties will follow the forecasting and Provisioning requirements of this Agreement for the appropriate sizing of trunks, and use of direct End Office Switch versus Tandem Switch routing. See Section 7.2.2.1.3.
LIS Forecasting. 7.2.2.8.1 Both CLEC and Qwest shall work in good faith to define a mutually agreed upon forecast of LIS trunking. 7.2.2.8.2 Both Parties shall have the obligation to participate in joint planning meetings at quarterly intervals to establish trunk design and provisioning requirements. The Parties agree to provide mutual trunk forecast information t ensure end user call completion between the Parties’ networks. Such forecasts shall be for LIS trunking which impacts the switch capacity and facilities of each Party. 7.2.2.8.3 Switch capacity growth requiring the addition of new switching modules may require six months to order and install. To align with the timeframe needed to provide for the requested facilities, including engineering, ordering, installation and make ready activities, the Parties will utilize Qwest standard forecast timelines, as defined in the standard Qwest LIS Trunk Forecast Forms for growth planning. For capacity growth, Qwest will utilize CLEC forecasts to ensure availability of switch capacity. 7.2.2.8.4 [SEE STATE SPECIFIC LANGUAGE FOR UT]Each Party will utilize the Forecast cycle outlined on the Qwest LIS Trunk Forecast Forms, which stipulates that forecasts be submitted on a quarterly basis. The forecast will identify trunking requirements for a two (2) year period. From the quarterly close date as outlined in the forecast cycle, the receiving Party will have one month to determine network needs and place vendor orders which may require a six (6) month interval to complete the network build. Seven (7) months after submission of the initial forecast, Qwest will have the necessary capacity in place to meet the CLEC forecast. After the initial forecast, Qwest will ensure that capacity is available to meet CLECs’ needs. For ordering information see the Interconnection Section of this Agreement. 7.2.2.8.5 Both Parties will follow the forecasting and provisioning requirements of this Agreement for the appropriate sizing of trunks, and use of direct end office vs. tandem routing.
LIS Forecasting. 7.2.2.8.1 Both CLEC and Qwest shall work in good faith to define a mutually agreed upon forecast of LIS trunking. 7.2.2.8.2 Both Parties shall have the obligation to participate in joint planning meetings at semi annual intervals to establish trunk design and provisioning requirements. The Parties agree to provide mutual trunk forecast information to ensure end user call completion between the Parties’ networks. Such forecasts shall be for LIS trunking which impacts the switch capacity and facilities of each Party. Qwest shall provide trunk group specific projections to the CLEC on or before the date of the joint planning meeting. 7.2.2.8.3 Switch capacity growth requiring the addition of new switching modules may require six months to order and install. To align with the timeframe needed to provide for the requested facilities, including engineering, ordering, installation and make ready activities, Qwest will utilize CLEC semi-annual forecasts and near-term demand submitted on Unforecast Demand Notification Forms to ensure availability of switch capacity. 7.2.2.8.4 The forecast will identify trunking requirements for a two (2) year period. From the semi-annual close date as outlined in the forecast cycle, the receiving Party will have one (1) month to determine network needs and place vendor orders which may require a six (6) month interval to complete the network build. Seven

Related to LIS Forecasting

  • TRUNK FORECASTING 57.1. CLEC shall provide forecasts for traffic utilization over trunk groups. Orders for trunks that exceed forecasted quantities for forecasted locations will be accommodated as facilities and/or equipment are available. Sprint shall make all reasonable efforts and cooperate in good faith to develop alternative solutions to accommodate orders when facilities are not available. Company forecast information must be provided by CLEC to Sprint twice a year. The initial trunk forecast meeting should take place soon after the first implementation meeting. A forecast should be provided at or prior to the first implementation meeting. The semi-annual forecasts shall project trunk gain/loss on a monthly basis for the forecast period, and shall include: 57.1.1. Semi-annual forecasted trunk quantities (which include baseline data that reflect actual Tandem and end office Local Interconnection and meet point trunks and Tandem-subtending Local Interconnection end office equivalent trunk requirements) for no more than two years (current plus one year); 57.1.2. The use of Common Language Location Identifier (CLLI-MSG), which are described in Telcordia documents BR ▇▇▇-▇▇▇-▇▇▇ and BR ▇▇▇-▇▇▇-▇▇▇; 57.1.3. Description of major network projects that affect the other Party will be provided in the semi-annual forecasts. Major network projects include but are not limited to trunking or network rearrangements, shifts in anticipated traffic patterns, or other activities by CLEC that are reflected by a significant increase or decrease in trunking demand for the following forecasting period. 57.1.4. Parties shall meet to review and reconcile the forecasts if forecasts vary significantly.

  • Forecasting Manager and Sprint PCS will work cooperatively to generate mutually acceptable forecasts of important business metrics including traffic volumes, handset sales, subscribers and Collected Revenues for the Sprint PCS Products and Services. The forecasts are for planning purposes only and do not constitute Manager's obligation to meet the quantities forecast.