Layout Drawings Sample Clauses
Layout Drawings. Unless noted otherwise in the Agreement, formwork layout drawings (for erection of the equipment and the typical use at Customer’s project) are not included. Should such drawings be requested, they will be billed at a rate of $150.00 per hour. Unless noted otherwise, layout drawings will be based on CAN/CSA design standards. Any layout drawings furnished by DOKA to Customer are provided to conceptually illustrate the assembly of DOKA’s products only. Such Layout Drawings are not intended to be fully directive nor cover engineering details on DOKA’s products, or equipment or material not furnished by DOKA, or the interconnection therewith. DOKA does not control assembly or procedures at the project site, or the grade or quality of materials or equipment supplied by third parties. It is the responsibility of Customer to integrate DOKA’s drawings into composite drawings suitably complete for construction purposes consistent with safe practice and overall project objectives. Drawings stamped by a licensed professional engineer (member in good standing of his provincial professional order) are not included. If Customer requests drawings for standard application of standard products to be reviewed and stamped by a licensed professional engineer, the charge for this service is $800.00 per sheet. Any additional engineering services or calculations will be billed at $200.00/hour per day (up to 8 hours) and at $300.00/hour for overtime hours.
Layout Drawings. Unless noted otherwise in the Agreement, formwork layout drawings (for erection of the equipment and the typical use at Customer’s project) are not included. Should such drawings be requested, they will be billed at a rate of $100 per hour. Unless noted otherwise, layout drawings will be based on CAN/CSA design standards. Any layout drawings furnished by DOKA to Customer are provided to conceptually illustrate the assembly of DOKA’s products only. Such Layout Drawings are not intended to be fully directive nor cover engineering details on DOKA’s products, or equipment or material not furnished by DOKA, or the interconnection therewith. DOKA does not control assembly or procedures at the project site, or the grade or quality of materials or equipment supplied by third parties. It is the responsibility of Customer to integrate DOKA’s drawings into composite drawings suitably complete for construction purposes consistent with safe practice and overall project objectives. Drawings stamped by a professional engineer (<P.E.=) are not included. If Customer requests drawings for standard application of standard products to be reviewed and stamped by a licensed professional engineer, the charge for this service is $800 per sheet. Any additional Engineering services or calculations will be billed at $200/hour ($300 for overtime hours).
Layout Drawings. 1. The location of each pipe section and special piece, with each piece numbered or otherwise
2. All outlets and bends to be made up into special lengths so that when installed they will be
3. Show each pipe and fitting marked on the outside and inside to indicate the location sequence number on the laying plan.