Gravimetric method Clause Samples

Gravimetric method. 3.3.1. Metering a limited quantity of pure gas (CO or C3H8) by means of a gravimetric technique. 3.3.2. The following gravimetric procedure may be used to verify the CVS system. The weight of a small cylinder filled with either carbon monoxide or propane is determined with a precision of ± 0.01 g. For about 5 to 10 minutes, the CVS system is operated as in a normal exhaust emission test, while CO or propane is injected into the system. The quantity of pure gas involved is determined by means of differential weighing. The gas accumulated in the bag is then analysed by means of the equipment normally used for exhaust-gas analysis. The results are then compared to the concentration figures computed previously.
Gravimetric method. 3.3.1. Metering a limited quantity of pure gas (CO or C3H8) by means of a gravimetric technique 3.3.2. The following gravimetric procedure may be used to verify the CVS system. The weight of a small cylinder filled with either carbon monoxide or propane is determined with a precision of ±0.
Gravimetric method extraordinary events such as bushfires, prescribed burning, dust storms, sea fog, fire incidents or any other activity agreed by the Secretary. e “Reasonable and feasible avoidance measures” includes, but is not limited to, the operational requirements in conditions 14, 15 and 16 to develop and implement an air quality management system that ensures operational responses to the risks of exceedance of the criteria.
Gravimetric method. Metering a limited quantity of pure gas (CO or C3H8) by means of a gravimetric technique.

Related to Gravimetric method

  • PayPal as Login Method We may allow you to authenticate with PayPal when you log into certain external websites or mobile apps. If we do so, we may share your login status with any third party enabling you to log in in this way, as well as the personal and other account information that you consent to being shared so that the third party can recognize you. PayPal will not give the third party access to your account and will only make payments from your account to that third party with your specific authorization and instruction.

  • Measurement method An isolation resistance test instrument is connected between the live parts and the electrical chassis. The isolation resistance is subsequently measured by applying a DC voltage at least half of the working voltage of the high voltage bus. If the system has several voltage ranges (e.g. because of boost converter) in conductively connected circuit and some of the components cannot withstand the working voltage of the entire circuit, the isolation resistance between those components and the electrical chassis can be measured separately by applying at least half of their own working voltage with those components disconnected.

  • Billing Method 2.6.1 To receive payment for services rendered pursuant to this contract the Contractor shall submit a fully completed invoice for work previously performed to: 2.6.2 At a minimum, the invoice shall detail the following information: 2.6.2.1 Unique invoice number; 2.6.2.2 Contractor’s name, address, and telephone number; 2.6.2.3 Date of invoice and/or billing period; 2.6.2.4 Applicable Contract No.;

  • Geometric visibility The visibility of the illuminating surface, including its visibility in areas which do not appear to be illuminated in the direction of observation considered, shall be ensured within a divergent space defined by generating lines based on the perimeter of the illuminating surface and forming an angle of not less than 5° with the axis of reference of the headlamp.

  • Test method This test is intended to demonstrate the immunity of the vehicle electronic systems. The vehicle shall be subject to electromagnetic fields as described in this annex. The vehicle shall be monitored during the tests. If not otherwise stated in this annex the test shall be performed according to ISO 11451-2.