Common use of Facility Commissioning Clause in Contracts

Facility Commissioning. The goal of this task is to perform the testing required to commission the commercial-scale BCP RNG production facility and co-located fueling station, including hosting a ribbon cutting ceremony to celebrate facility commissioning. • Develop and implement a Cold Testing Plan for the facility that will detail the process, deliverables, and milestones associated with the cold testing of the facility. Cold testing refers to testing without material. The Cold Testing Plan will include, but is not limited to, the following: o A description of the equipment to be tested o A description of the methodology to test the identified equipment, including testing for required carbon intensity and projected DGE capacity o A list of goals and objectives for the test o A description of the quality control and quality assurance practices for the test methodology • Develop and implement a Cold Testing Report for the facility that will evaluate the cold test results. The Cold Testing Report will include, but is not limited to, the following: o A description of the results of the cold test for the identified equipment o A description of any major changes that were made based on findings during the cold testing • Develop and implement a Hot Testing Plan for the facility that will detail the process, deliverables, and milestones associated with the hot testing of the facility. Hot testing refers to testing with material. The Hot Testing Plan will include, but is not limited to, the following: o A description of the equipment to be tested o A description of the methodology to test the identified equipment, including testing for required carbon intensity and projected DGE capacity o A list of goals and objectives for the test o A description of the quality control and quality assurance practices for the test methodology • Prepare and provide a Hot Testing Report for the facility that will evaluate the hot test results. The Hot Testing Report will include, but is not limited to, the following: o A description of the results of the hot test for the identified equipment o A description of any major changes that were made based on findings during the hot testing • Prepare and provide Written Notification of Completion of Commissioning for the facility that will notify the CAM that commissioning activities have been completed and that the facility is ready to commence commercial operations. • Host public Ribbon Cutting Ceremony for invited stakeholders, elected officials, project partners, community organizations, community leaders, and the general public. Prepare and provide a Ribbon Cutting Ceremony Activities Report to the CAM, which, at a minimum, will have: o A list invited parties o Final number of attendees o Description of the event o Photos and/or videos of the event • Operate facility at less than 50% of full capacity for two months to validate the performance of the equipment, including required carbon intensity and projected DGE capacity. • Operate facility at 100% of full capacity. Prepare and provide a Written Notification of Achievement of Full-Scale Production for the facility that will notify the CAM that the facility is ready to commence commercial operations at full capacity. • Cold Testing Plan • Cold Testing Report • Hot Testing Plan • Hot Testing Report • Written Notification of Completion of Commissioning • Ribbon Cutting Ceremony Activities Report • Written Notification of Achievement of Full-Scale Production

Appears in 1 contract

Sources: Grant Agreement

Facility Commissioning. The goal of this task subtask is to perform the testing required to commission the commercialcommunity-scale BCP RNG production bioenergy facility and co-located fueling station, including hosting a ribbon cutting ceremony to celebrate facility commissioningusing Kompogas technology. • Develop Prepare and implement provide a Cold Testing Plan for the facility that will detail the process, deliverables, and milestones associated with the cold testing of the facility. Cold testing refers to testing without material. The Cold Testing Plan will include, but is not limited to, the following: o A description of the equipment to be tested tested; o A description of the methodology to test the identified equipment, including testing for required carbon intensity and projected DGE capacity ; o A list of goals and objectives for the test test; and o A description of the quality control and quality assurance practices for the test methodology methodology. Develop Implement the Cold Testing Plan. • Prepare and implement provide a Cold Testing Report for the facility that will evaluate the cold test results. The Cold Testing Report will include, but is not limited to, the following: o A description of the results of the cold test for the identified equipment equipment; and o A description of any major changes that were made based on findings during the cold testing testing. Develop Prepare and implement provide a Hot Testing Plan for the facility that will detail the process, deliverables, and milestones associated with the hot testing of the facility. Hot testing refers to testing with material. Food-waste that is typically landfilled, FOG, and/or GTW should make up at least 70% of the total project feedstock material. The Hot Testing Plan will include, but is not limited to, the following: o A description of the equipment to be tested tested; o A description of the methodology to test the identified equipment, including testing for required carbon intensity and projected DGE capacity ; o A list of goals and objectives for the test test; and o A description of the quality control and quality assurance practices for the test methodology methodology. • Implement the Hot Testing Plan. • Prepare and provide a Hot Testing Report for the facility that will evaluate the hot test results. The Hot Testing Report will include, but is not limited to, the following: o A description of the results of the hot test for the identified equipment equipment; and o A description of any major changes that were made based on findings during the hot testing testing. • Prepare and provide Written Notification of Completion of Commissioning for the facility that will notify the CAM that commissioning activities have been completed and that the facility is ready to commence commercial operations. • Host public Ribbon Cutting Ceremony for invited stakeholders, elected officials, project partners, community organizations, community leaders, and the general public. Prepare and provide Participate in a Ribbon Cutting Ceremony Activities Report to the CAM, which, at a minimum, will have: o A list invited parties o Final number of attendees o Description of the event o Photos and/or videos of the event • Operate facility at less than 50% of full capacity for two months to validate the performance of the equipment, including required carbon intensity and projected DGE capacityCPR Meeting in accordance with subtask 1.3. • Operate facility at 100% of full capacity. Prepare and provide a Written Notification of Achievement of Full-Scale Production for the facility that will notify the CAM that the facility is ready to commence commercial operations at full capacityCPR Report in accordance with subtask 1.3. • Cold Testing Plan • Cold Testing Report (draft and final) • Hot Testing Plan • Hot Testing Report (draft and final) • Written Notification of Completion of Commissioning • Ribbon Cutting Ceremony Activities Report • Written Notification of Achievement of Full-Scale ProductionCPR Report

Appears in 1 contract

Sources: Grant Agreement