Energization Plan Sample Clauses

The Energization Plan clause defines the requirements and procedures for safely and systematically energizing electrical systems or equipment within a project. It typically outlines the steps, documentation, and approvals needed before power is applied, such as coordination with relevant parties, safety checks, and scheduling. This clause ensures that the energization process is controlled and transparent, minimizing risks of accidents, equipment damage, or project delays.
Energization Plan. Interconnection Customer has selected ERIS under this Agreement. The Parties acknowledge that for ERIS to be provided, the Network Upgrades and Interconnection Facilities described in this Appendix A must be constructed, tested, energized and placed into operation. The process and timelines for the implementation of energization, testing and operation of the Network Upgrades and Interconnection Facilities is established in the Facilities Use Agreement and accompanying transmittal letter filed by Western Spirit Transmission on April 21, 2020 and accepted on June 19, 2020, in Docket No. ER20-1616 (“Western Spirit Energization Plan”). The Western Spirit Energization Plan anticipates testing and energization of the Western Spirit Substation to ▇▇▇▇▇▇ Corners Substation segment of the Western Spirit Project (“Northern Segment”) and subsequently the Western Spirit Substation to Pajarito Substation segment of the Western Spirit Project (“Western Segment”) before such facilities are transferred to Transmission Provider pursuant to the BTA (such period, the “Energization Period”). Interconnection Customer will be able to flow power over each of the Northern Segment and Western Segment during the Energization Period. Pursuant to the Western Spirit Energization Plan, during the Energization Period, the Point of Interconnection will be at the ▇▇▇▇▇▇ Corners Substation and Transmission Provider will not own any transmission facilities between the Point of Interconnection and the Large Generating Facility. After the Energization Period, the Point of Interconnection will be located at the Western Spirit Substation 345 kV bus and, as explained below in Section D.2 and Appendix B, Transmission Provider will own the last section of the 345 kV transmission lines entering the Western Spirit Substation and the Point of Change of Ownership will be at the insulators on the last structure located outside the perimeter fence of the Western Spirit Substation. See Exhibits 1 and 2 to Appendix C.